Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BROCK heat pump efficiency: 36 outdoor models compared
BROCK has 36 heat pump outdoor models certified with this refrigerant group, in 3,770 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes BROCK makes. BROCK has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 36
- AHRI certifications
- 3,770
- Efficiency index
- 35%
- Typical model vs same-size, same-type peers (36 models)
- Meet CEE 2025
- 19.4%
- 7 models
How BROCK compares with comparable models
- BROCK
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index36 models scored | 35% | Not ranked | — |
| COP at 5°F36 models scored | 41% | Not ranked | 1.80 |
| Capacity retention at 5°F36 models scored | 13% | Not ranked | 41% |
| HSPF236 models scored | 24% | Not ranked | 6.7 |
| SEER236 models scored | 24% | Not ranked | 13.4 |
| EER236 models scored | 64% | Not ranked | 11.1 |
| Heating capacity at 5°F36 models scored | 17% | Not ranked | 17,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 19.4% | 7 |
| CEE 2026 Tier 1 (Split ASHP) | 11.1% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- BROCK (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 45% | 70% | 19% | 42% |
| Ducted, 2 tons | 4 | 35% | 42% | 25% | 27% |
| Ducted, 2.5–3 tons | 11 | 35% | 46% | 24% | 22% |
| Ducted, 3.5–4.5 tons | 17 | 31% | 31% | 20% | 21% |
| Ducted, 5 tons and up | 2 | 61% | 74% | 59% | 38% |
Every BROCK model in the market
- BROCK models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top BROCK models
Cold-climate picks
No BROCK model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PH8TAN560**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60L | 5 tons57,500 Btu/h · Ducted | 53% | 2.30 | 8.1 | 17.5 | 13.0 | CEE 25CEE 26 | 132 | 215560743 | Ducted, 3.5–4.5 tons | 80.2 | 69.3 | 91.1 | Not a pick |
| 2PH8TAN548**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D6021X | 4 tons49,500 Btu/h · Ducted | 50% | 2.32 | 8.5 | 18.0 | 13.0 | CEE 25CEE 26 | 202 | 218695444 | Ducted, 3.5–4.5 tons | 72.7 | 57.3 | 88.0 | Not a pick |
| 3PH8TAN536**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60L | 3 tons36,000 Btu/h · Ducted | 49% | 2.48 | 8.5 | 17.0 | 13.0 | CEE 25CEE 26 | 289 | 215628948 | Ducted, 2.5–3 tons | 66.7 | 56.3 | 77.2 | Not a pick |
| 4PH5SAN560**AA*BROCK · 15 SEER2 HPwith ducted air handler PF5TNBD60L | 5 tons57,000 Btu/h · Ducted | 52% | 2.18 | 7.8 | 15.2 | 12.5 | None | 4 | 214601979 | Ducted, 5 tons and up | 64.6 | 62.0 | 67.3 | Not a pick |
| 5PH8TAN524**AA*BROCK · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace PG80MSUA48060B | 2 tons23,800 Btu/h · Ducted | 45% | 2.24 | 8.5 | 18.0 | 13.5 | CEE 25 | 391 | 215647876 | Ducted, 2 tons | 60.6 | 45.1 | 76.1 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | PH8TAN536**AA* | 2.48 | Ducted, 2.5–3 tons | 92% | 215628948 |
| Capacity retention at 5°F | PH5SAN560**AA*Also listed as PH5SAP560**AA | 52% | Ducted, 5 tons and up | 41% | 214101948 |
| HSPF2 | PH8TAN548**AA* | 8.5 | Ducted, 3.5–4.5 tons | 58% | 215625061 |
| SEER2 | PH8TAN560**AA* | 17.5 | Ducted, 5 tons and up | 81% | 215560743 |
| EER2 | PH8TAN548**AA* | 13.5 | Ducted, 3.5–4.5 tons | 99% | 215560717 |
| Heating capacity at 5°F | PH5SAN518**AA* | 8,600 Btu/h | Ducted, up to 1.5 tons | 44% | 214102236 |
BROCK size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | 48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 217702474 |
| Ducted, 2 tons | None on this board (0 of 4 models qualify) | 60.6(50 is the typical model of its size class)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 215647876 |
| Ducted, 2.5–3 tons | None on this board (0 of 11 models qualify) | 66.7(50 is the typical model of its size class)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 215628948 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 17 models qualify) | 72.7(50 is the typical model of its size class)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 218695444 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 80.2(50 is the typical model of its size class)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743 |
Newest BROCK certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| PH8TAN560**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D6021X | 5 tons58,000 Btu/h · Ducted | 2.34 | 51% | 8.1 | 17.5 | CEE 25CEE 26 | 132 | 218695461 |
| PH8TAN548**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D6021X | 4 tons49,500 Btu/h · Ducted | 2.32 | 50% | 8.5 | 18.0 | CEE 25CEE 26 | 202 | 218695444 |
| PH8TAN536**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D4821X | 3 tons38,000 Btu/h · Ducted | 2.24 | 47% | 8.1 | 16.5 | CEE 25CEE 26 | 289 | 218695410 |
| PH8TAN524**AA*BROCK · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D3617X | 2 tons24,000 Btu/h · Ducted | 2.16 | 46% | 7.8 | 18.0 | CEE 25 | 391 | 218695376 |
| PH5SAN518**AA*BROCK · 15 SEER2 HPwith ducted air handler FM(C,U)5S30**AL | 1.5 tons18,000 Btu/h · Ducted | 2.05 | 47% | 8.0 | 15.2 | None | 317 | 218452516 |
Compare BROCK
BROCK includes these brand names as listed in AHRI: BROCK. Standards are checked against published thresholds; program rules beyond ratings are not checked.