Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BROCK vs Wells heat pumps
Measured against models of the same size and duct type, Wells scores higher on 5 of the 6 ratings. BROCK has 36 outdoor models, Wells has 37 outdoor models. BROCK and Wells have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BROCK
- Wells
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BROCK | Wells |
|---|---|---|
| Efficiency index | 35%median — | 63%median — |
| COP at 5°F | 41%median 1.80 | 64%median 2.10 |
| Capacity retention at 5°F | 13%median 41% | 61%median 75% |
| HSPF2 | 24%median 6.7 | 74%median 10.0 |
| SEER2 | 24%median 13.4 | 62%median 19.4 |
| EER2 | 64% (higher)median 11.1 | 59% (higher)median 12.0 |
| Heating capacity at 5°F | 17%median 17,000 Btu/h | 62%median 19,000 Btu/h |
| Outdoor models | 36 | 37 |
| AHRI certifications | 3,770 | 121 |
Share of models meeting each standard
| Standard | BROCK | Wells |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 19.4%7 models | 86.5%32 models |
| CEE 2026 Tier 1 (Split ASHP) | 11.1%4 models | 83.8%31 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 2.7%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 81.1%30 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 2.7%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 83.8%31 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BROCK
- Wells
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BROCK | Wells |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 45% | 9 · index 80% |
| Ducted, 2 tons | 4 · index 35% | 5 · index 73% |
| Ducted, 2.5–3 tons | 11 · index 35% | 7 · index 67% |
| Ducted, 3.5–4.5 tons | 17 · index 31% | 7 · index 63% |
| Ducted, 5 tons and up | 2 · index 61% | 1 · index 63% |
| Non-ducted, up to 1.5 tons | None | 16 · index 58% |
| Non-ducted, 2 tons | None | 4 · index 53% |
| Non-ducted, 2.5–3 tons | None | 4 · index 54% |
| Non-ducted, 3.5–4.5 tons | None | 3 · index 57% |
| Non-ducted, 5 tons and up | None | 1 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BROCKCold-climate score, best model | WellsCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | 93.5(50 is the typical model of its size class)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models qualify · AHRI 215864077 |
| Ducted, 2 tons | None on this board (0 of 4 models qualify) | 85.7(50 is the typical model of its size class)WOS-24PRE/230with ducted air handler WIDH-24MOC/2305 of 5 models qualify · AHRI 215864084 |
| Ducted, 2.5–3 tons | None on this board (0 of 11 models qualify) | 82.5(50 is the typical model of its size class)WOM-36HH5/2307 of 7 models qualify · AHRI 215864112 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 17 models qualify) | 82.7(50 is the typical model of its size class)WOM-48HH6/2307 of 7 models qualify · AHRI 215864115 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | No models in this size class | 94.4(50 is the typical model of its size class)WOS-06PRE/230with ductless indoor unit WI1C-06MOC/23011 of 16 models qualify · AHRI 215864073 |
| Non-ducted, 2 tons | No models in this size class | 89.4(50 is the typical model of its size class)WOS-24PRE/230with ductless indoor unit WI4C-24MOC/2304 of 4 models qualify · AHRI 215864072 |
| Non-ducted, 2.5–3 tons | No models in this size class | 72.6(50 is the typical model of its size class)WOM-36HH5/2304 of 4 models qualify · AHRI 215864113 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 69.9(50 is the typical model of its size class)WOM-60HH6/2303 of 3 models qualify · AHRI 215864119 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | BROCKAll-around score, best model | WellsAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 217702474 | 95.0(50 is the typical model of its size class) (higher)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models have all five ratings · AHRI 215864077 |
| Ducted, 2 tons | 60.6(50 is the typical model of its size class)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 215647876 | 79.6(50 is the typical model of its size class) (higher)WDHP-2436T-Gwith ducted air handler WDAH-24MOC-G5 of 5 models have all five ratings · AHRI 217048501 |
| Ducted, 2.5–3 tons | 66.7(50 is the typical model of its size class)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 215628948 | 83.6(50 is the typical model of its size class) (higher)WOM-36HH5/2307 of 7 models have all five ratings · AHRI 215864112 |
| Ducted, 3.5–4.5 tons | 72.7(50 is the typical model of its size class)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 218695444 | 85.1(50 is the typical model of its size class) (higher)WOM-48RH6/2307 of 7 models have all five ratings · AHRI 215864100 |
| Ducted, 5 tons and up | 80.2(50 is the typical model of its size class) (higher)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743 | 62.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864103 |
| Non-ducted, up to 1.5 tons | No models in this size class | 93.8(50 is the typical model of its size class)WOS-06PRE/230with ductless indoor unit WIHW-06MOC/23016 of 16 models have all five ratings · AHRI 215864044 |
| Non-ducted, 2 tons | No models in this size class | 74.3(50 is the typical model of its size class)WOS-24QUA/230with ductless indoor unit WIHW-24MOC/2304 of 4 models have all five ratings · AHRI 215864043 |
| Non-ducted, 2.5–3 tons | No models in this size class | 66.3(50 is the typical model of its size class)WOM-36HH5/2304 of 4 models have all five ratings · AHRI 215864111 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 62.6(50 is the typical model of its size class)WOM-60HH6/2303 of 3 models have all five ratings · AHRI 215864117 |
| Non-ducted, 5 tons and up | No models in this size class | 32.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864102 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BROCK | Wells |
|---|---|---|
| COP at 5°F | beats 92% · 2.48PH8TAN536**AA*Ducted, 2.5–3 tons | beats 99% · 2.51WOS-12QUA/230Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 41% · 52%PH5SAN560**AA*Also listed as PH5SAP560**AADucted, 5 tons and up | beats 98% · 126%WOS-09PRE/230Non-ducted, up to 1.5 tons |
| HSPF2 | beats 58% · 8.5PH8TAN548**AA*Ducted, 3.5–4.5 tons | beats 99% · 11.0WOM-48HH6/230Ducted, 3.5–4.5 tons |
| SEER2 | beats 81% · 17.5PH8TAN560**AA*Ducted, 5 tons and up | beats 96% · 20.4WOM-48RH6/230Ducted, 3.5–4.5 tons |
| EER2 | beats 99% · 13.5PH8TAN548**AA*Ducted, 3.5–4.5 tons | beats 99% · 14.4WOS-06PRE/230Ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 44% · 8,600 Btu/hPH5SAN518**AA*Ducted, up to 1.5 tons | beats 97% · 39,000 Btu/hWDHP-36HHDucted, 2.5–3 tons |