Wells heat pump efficiency: 37 outdoor models compared
Wells has 37 heat pump outdoor models certified with this refrigerant group, in 121 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Wells makes. Wells has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 37
- AHRI certifications
- 121
- Efficiency index
- 63%
- Typical model vs same-size, same-type peers (57 models)
- Meet CEE 2025
- 86.5%
- 32 models
How Wells compares with comparable models
- Wells
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index57 models scored | 63% | Not ranked | — |
| COP at 5°F57 models scored | 64% | Not ranked | 2.10 |
| Capacity retention at 5°F57 models scored | 61% | Not ranked | 75% |
| HSPF257 models scored | 74% | Not ranked | 10.0 |
| SEER257 models scored | 62% | Not ranked | 19.4 |
| EER257 models scored | 59% | Not ranked | 12.0 |
| Heating capacity at 5°F57 models scored | 62% | Not ranked | 19,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 86.5% | 32 |
| CEE 2026 Tier 1 (Split ASHP) | 83.8% | 31 |
| CEE Advanced Tier (Split ASHP) | 2.7% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 81.1% | 30 |
| DOE Cold Climate Heat Pump Challenge | 2.7% | 1 |
| ENERGY STAR Cold Climate | 83.8% | 31 |
Sizes and duct types offered
- Wells (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 9 | 80% | 77% | 89% | 81% |
| Ducted, 2 tons | 5 | 73% | 61% | 80% | 80% |
| Ducted, 2.5–3 tons | 7 | 67% | 51% | 82% | 68% |
| Ducted, 3.5–4.5 tons | 7 | 63% | 50% | 78% | 71% |
| Ducted, 5 tons and up | 1 | 63% | 66% | 82% | 89% |
| Non-ducted, up to 1.5 tons | 16 | 58% | 76% | 68% | 52% |
| Non-ducted, 2 tons | 4 | 53% | 73% | 58% | 47% |
| Non-ducted, 2.5–3 tons | 4 | 54% | 31% | 70% | 47% |
| Non-ducted, 3.5–4.5 tons | 3 | 57% | 62% | 59% | 52% |
| Non-ducted, 5 tons and up | 1 | 27% | 42% | 18% | 16% |
Every Wells model in the market
- Wells models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Wells models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WOS-06PRE/230Wells · WOS Serieswith ductless indoor unit WI1C-06MOC/230 | 0.5 tons6,500 Btu/h · Non-ducted | 109% | 2.40 | 12.0 | 8,100 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215864073 | Non-ducted, up to 1.5 tons | 94.4 |
| 2WOS-06PRE/230Wells · WOS Serieswith ducted air handler WIDL-06MOC/230 | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26XcelES CC | 3 | 215864077 | Ducted, up to 1.5 tons | 93.5 |
| 3WOS-09QUA/230Wells · WOS Serieswith ductless indoor unit WICS-09MOC/230 | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 8,600 | 26.0 | CEE 25CEE 26XcelES CC | 6 | 215864064 | Non-ducted, up to 1.5 tons | 89.5 |
| 4WOS-24PRE/230Wells · WOS Serieswith ductless indoor unit WI4C-24MOC/230 | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 5 | 215864072 | Non-ducted, 2 tons | 89.4 |
| 5WOS-24PRE/230Wells · WOS Serieswith ducted air handler WIDH-24MOC/230 | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 5 | 215864084 | Ducted, 2 tons | 85.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WOS-06PRE/230Wells · WOS Serieswith ducted air handler WIDL-06MOC/230 | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 3 | 215864077 | Ducted, up to 1.5 tons | 95.0 | 93.5 | 96.5 | 93.5 |
| 2WOS-06PRE/230Wells · WOS Serieswith ductless indoor unit WIHW-06MOC/230 | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 25.3 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215864044 | Non-ducted, up to 1.5 tons | 93.8 | 93.8 | 93.9 | 94.4 |
| 3WOS-09QUA/230Wells · WOS Serieswith ductless indoor unit WICS-09MOC/230 | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 6 | 215864064 | Non-ducted, up to 1.5 tons | 92.6 | 89.5 | 95.7 | 89.5 |
| 4WOS-09PRE/230Wells · WOS Serieswith ducted air handler WIDL-09MOC/230 | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26XcelES CC | 6 | 215864078 | Ducted, up to 1.5 tons | 86.7 | 80.0 | 93.5 | 80.0 |
| 5WOM-48RH6/230Wells · WOM Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 215864100 | Ducted, 3.5–4.5 tons | 85.1 | 77.9 | 92.3 | 77.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WOS-12QUA/230 | 2.51 | Non-ducted, up to 1.5 tons | 99% | 215864065 |
| Capacity retention at 5°F | WOS-09PRE/230 | 126% | Non-ducted, up to 1.5 tons | 98% | 215864085 |
| HSPF2 | WOM-48HH6/230 | 11.0 | Ducted, 3.5–4.5 tons | 99% | 215864115 |
| SEER2 | WOM-48RH6/230 | 20.4 | Ducted, 3.5–4.5 tons | 96% | 215864100 |
| EER2 | WOS-06PRE/230 | 14.4 | Ducted, up to 1.5 tons | 99% | 215864077 |
| Heating capacity at 5°F | WDHP-36HH | 39,000 Btu/h | Ducted, 2.5–3 tons | 97% | 215864029 |
Wells size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.5(50 is the typical model of its size class)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models qualify · AHRI 215864077 | 95.0(50 is the typical model of its size class)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models have all five ratings · AHRI 215864077 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)WOS-24PRE/230with ducted air handler WIDH-24MOC/2305 of 5 models qualify · AHRI 215864084 | 79.6(50 is the typical model of its size class)WDHP-2436T-Gwith ducted air handler WDAH-24MOC-G5 of 5 models have all five ratings · AHRI 217048501 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)WOM-36HH5/2307 of 7 models qualify · AHRI 215864112 | 83.6(50 is the typical model of its size class)WOM-36HH5/2307 of 7 models have all five ratings · AHRI 215864112 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)WOM-48HH6/2307 of 7 models qualify · AHRI 215864115 | 85.1(50 is the typical model of its size class)WOM-48RH6/2307 of 7 models have all five ratings · AHRI 215864100 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 62.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864103 |
| Non-ducted, up to 1.5 tons | 94.4(50 is the typical model of its size class)WOS-06PRE/230with ductless indoor unit WI1C-06MOC/23011 of 16 models qualify · AHRI 215864073 | 93.8(50 is the typical model of its size class)WOS-06PRE/230with ductless indoor unit WIHW-06MOC/23016 of 16 models have all five ratings · AHRI 215864044 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)WOS-24PRE/230with ductless indoor unit WI4C-24MOC/2304 of 4 models qualify · AHRI 215864072 | 74.3(50 is the typical model of its size class)WOS-24QUA/230with ductless indoor unit WIHW-24MOC/2304 of 4 models have all five ratings · AHRI 215864043 |
| Non-ducted, 2.5–3 tons | 72.6(50 is the typical model of its size class)WOM-36HH5/2304 of 4 models qualify · AHRI 215864113 | 66.3(50 is the typical model of its size class)WOM-36HH5/2304 of 4 models have all five ratings · AHRI 215864111 |
| Non-ducted, 3.5–4.5 tons | 69.9(50 is the typical model of its size class)WOM-60HH6/2303 of 3 models qualify · AHRI 215864119 | 62.6(50 is the typical model of its size class)WOM-60HH6/2303 of 3 models have all five ratings · AHRI 215864117 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 32.5(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864102 |
Newest Wells certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WDHP-24HHWellswith ducted air handler H,A,DG21*30+TXV+TD | 2 tons23,000 Btu/h · Ducted | 1.70 | 86% | 8.8 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 217375110 |
| WDHP-30HHWellswith ducted air handler H,A,DG7J*36+TXV+TD | 2.5 tons28,400 Btu/h · Ducted | 1.80 | 88% | 9.3 | 15.2 | CEE 25CEE 26XcelES CC | 6 | 217375037 |
| WDHP-60HHWellswith ducted air handler H,A,DG35*48+TXV+TD | 4 tons45,500 Btu/h · Ducted | 1.80 | 71% | 7.9 | 15.0 | CEE 25CEE 26XcelES CC | 4 | 217375035 |
| WDHP-36HHWellswith ducted air handler H,A,DG7J*36+TXV+TD | 3 tons35,200 Btu/h · Ducted | 1.86 | 99% | 9.1 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 217375034 |
| WDHP-4860T-GWELLS · Ducted Central Airwith ducted air handler WDAH-60MOC-G | 4.5 tons55,500 Btu/h · Ducted | 2.10 | 75% | 8.6 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 217048504 |
Compare Wells
Wells includes these brand names as listed in AHRI: WELLS. Standards are checked against published thresholds; program rules beyond ratings are not checked.