TRUST AIR CONDITIONERS heat pump efficiency: 60 outdoor models compared
TRUST AIR CONDITIONERS has 60 heat pump outdoor models certified with this refrigerant group, in 177 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUST AIR CONDITIONERS makes. TRUST AIR CONDITIONERS has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 60
- AHRI certifications
- 177
- Efficiency index
- 60%
- Typical model vs same-size, same-type peers (93 models)
- Meet CEE 2025
- 83.3%
- 50 models
How TRUST AIR CONDITIONERS compares with comparable models
- TRUST AIR CONDITIONERS
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index93 models scored | 60% | Not ranked | — |
| COP at 5°F93 models scored | 59% | Not ranked | 2.00 |
| Capacity retention at 5°F93 models scored | 60% | Not ranked | 75% |
| HSPF293 models scored | 71% | Not ranked | 10.0 |
| SEER293 models scored | 62% | Not ranked | 19.4 |
| EER293 models scored | 52% | Not ranked | 11.7 |
| Heating capacity at 5°F93 models scored | 65% | Not ranked | 24,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 83.3% | 50 |
| CEE 2026 Tier 1 (Split ASHP) | 81.7% | 49 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 73.3% | 44 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 1 |
| ENERGY STAR Cold Climate | 75% | 45 |
Sizes and duct types offered
- TRUST AIR CONDITIONERS (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 12 | 71% | 74% | 77% | 75% |
| Ducted, 2 tons | 7 | 59% | 49% | 71% | 70% |
| Ducted, 2.5 to 3 tons | 14 | 65% | 58% | 79% | 70% |
| Ducted, 3.5 to 4.5 tons | 15 | 62% | 50% | 80% | 69% |
| Ducted, 5 tons and up | 3 | 64% | 75% | 86% | 84% |
| Non-ducted, up to 1.5 tons | 16 | 62% | 67% | 68% | 61% |
| Non-ducted, 2 tons | 5 | 58% | 71% | 59% | 58% |
| Non-ducted, 2.5 to 3 tons | 9 | 56% | 44% | 73% | 47% |
| Non-ducted, 3.5 to 4.5 tons | 10 | 47% | 55% | 57% | 36% |
| Non-ducted, 5 tons and up | 2 | 27% | 41% | 18% | 16% |
Every TRUST AIR CONDITIONERS model in the market
- TRUST AIR CONDITIONERS models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
TRUST AIR CONDITIONERS in the cold
- All listed models (median, middle 50% and 80%)
- TRUST AIR CONDITIONERS (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUST AIR CONDITIONERS, 47°F | 60 | 100% | 100% | 100% | 100% | 100% |
| TRUST AIR CONDITIONERS, 17°F | 60 | 63% | 69% | 73% | 81% | 85% |
| TRUST AIR CONDITIONERS, 5°F | 60 | 59% | 63% | 66% | 78% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUST AIR CONDITIONERS, 47°F | 60 | 2.87 | 3.1 | 3.28 | 3.51 | 3.74 |
| TRUST AIR CONDITIONERS, 17°F | 60 | 2.09 | 2.21 | 2.28 | 2.49 | 2.6 |
| TRUST AIR CONDITIONERS, 5°F | 60 | 1.85 | 1.96 | 2 | 2.1 | 2.26 |
Source: NEEP ccASHP list · as of
Top TRUST AIR CONDITIONERS models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OUS06H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC106H/I61P | 0.5 tons6,500 Btu/h · Non-ducted | 109% | 2.40 | 12.0 | 8,100 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217678094 | Non-ducted, up to 1.5 tons | 94.9 |
| 2OAH24H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ductless indoor unit IUMC424H/I61P | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 4 | 217678074 | Non-ducted, 2 tons | 90.1 |
| 3OAH36H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ductless indoor unit IUMFC36H/I61P | 3 tons36,400 Btu/h · Non-ducted | 104% | 2.02 | 10.8 | 39,500 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217678091 | Non-ducted, 2.5 to 3 tons | 89.4 |
| 4OUS09H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMW109H/I61P | 1 ton9,000 Btu/h · Non-ducted | 82% | 2.33 | 13.0 | 8,200 | 24.6 | CEE 25CEE 26XcelES CC | 5 | 217678061 | Non-ducted, up to 1.5 tons | 86.8 |
| 5OAH24H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDH24H/I63P | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 4 | 217678083 | Ducted, 2 tons | 85.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OUS06H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMW106H/I61P | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 25.3 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217678065 | Non-ducted, up to 1.5 tons | 94.5 | 94.5 | 94.4 | 94.9 |
| 2OUS09H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMW109H/I61P | 1 ton9,000 Btu/h · Non-ducted | 82% | 2.33 | 13.0 | 24.6 | 14.7 | CEE 25CEE 26XcelES CC | 5 | 217678061 | Non-ducted, up to 1.5 tons | 87.7 | 86.8 | 88.6 | 86.8 |
| 3OAH09H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDL09H/I63P | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26XcelES CC | 5 | 217678077 | Ducted, up to 1.5 tons | 87.1 | 80.6 | 93.6 | 80.6 |
| 4M6S48HS/O6S4PTRUST AIR CONDITIONERS · M6 SeriesAlso listed as M6S48HN/O6S4P | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217678145 | Ducted, 3.5 to 4.5 tons | 85.3 | 78.1 | 92.6 | 78.1 |
| 5M6H48HS/O6S4PTRUST AIR CONDITIONERS · M6 SeriesAlso listed as M6H48HN/O6S4P | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 217678130 | Ducted, 3.5 to 4.5 tons | 84.3 | 82.6 | 86.0 | 82.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | OUS12H/O6S4P | 2.51 | Non-ducted, up to 1.5 tons | 99% | 217678112 |
| Capacity retention at 5°F | OAH09H/O6S4P | 120% | Ducted, up to 1.5 tons | 98% | 217678080 |
| HSPF2 | M6H48HS/O6S4PAlso listed as M6H48HN/O6S4P | 11.0 | Ducted, 3.5 to 4.5 tons | 99% | 217678130 |
| SEER2 | M6H48HS/O6S4PAlso listed as M6H48HN/O6S4P | 20.4 | Ducted, 3.5 to 4.5 tons | 96% | 217678130 |
| EER2 | OUS06H/O6S4P | 16.0 | Non-ducted, up to 1.5 tons | 96% | 217678065 |
| Heating capacity at 5°F | OAH36H/O6S4P | 39,500 Btu/h | Non-ducted, 2.5 to 3 tons | 98% | 217678091 |
TRUST AIR CONDITIONERS size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.9(50 is the typical model of its size class)OAH18H/O6S4Pwith ducted air handler IUMDH18H/I63P10 of 12 models qualify · AHRI 217678082 | 87.1(50 is the typical model of its size class)OAH09H/O6S4Pwith ducted air handler IUMDL09H/I63P12 of 12 models have all five ratings · AHRI 217678077 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)OAH24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models qualify · AHRI 217678083 | 78.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models have all five ratings · AHRI 217678110 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)OAH36H/O6S4Pwith ducted air handler IUMDH36H/I63P11 of 14 models qualify · AHRI 217678084 | 83.9(50 is the typical model of its size class)M5H36HS/O6S4PAlso listed as M5H36HN/O6S4P14 of 14 models have all five ratings · AHRI 217678127 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)M6H48HS/O6S4PAlso listed as M6H48HN/O6S4P15 of 15 models qualify · AHRI 217678130 | 85.3(50 is the typical model of its size class)M6S48HS/O6S4PAlso listed as M6S48HN/O6S4P15 of 15 models have all five ratings · AHRI 217678145 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | 65.9(50 is the typical model of its size class)OUS60H/O6S4Pwith ducted air handler IUMDH60H/I63P3 of 3 models have all five ratings · AHRI 217678174 |
| Non-ducted, up to 1.5 tons | 94.9(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMC106H/I61P12 of 16 models qualify · AHRI 217678094 | 94.5(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMW106H/I61P16 of 16 models have all five ratings · AHRI 217678065 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)OAH24H/O6S4Pwith ductless indoor unit IUMC424H/I61P5 of 5 models qualify · AHRI 217678074 | 75.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ductless indoor unit IUMW124H/I61P5 of 5 models have all five ratings · AHRI 217678064 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models qualify · AHRI 217678091 | 67.1(50 is the typical model of its size class)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models have all five ratings · AHRI 217678091 |
| Non-ducted, 3.5 to 4.5 tons | 70.3(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P9 of 10 models qualify · AHRI 217678134 | 62.6(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P10 of 10 models have all five ratings · AHRI 217678132 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 32.9(50 is the typical model of its size class)M6S60HS/O6S4PAlso listed as M6S60HN/O6S4P2 of 2 models have all five ratings · AHRI 217678177 |
Newest TRUST AIR CONDITIONERS certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AE60H/O64PTRUST AIR CONDITIONERS · AE Serieswith ducted air handler AE60H/I64P | 4.5 tons54,000 Btu/h · Ducted | 1.82 | 70% | 8.1 | 16.0 | None | 1 | 218859489 |
| AE48H/O64PTRUST AIR CONDITIONERS · AE Serieswith ducted air handler AE48H/I64P | 4 tons48,000 Btu/h · Ducted | 1.85 | 70% | 8.2 | 15.2 | None | 1 | 218859488 |
| AE36H/O64PTRUST AIR CONDITIONERSwith ducted air handler AE36H/I64P | 3 tons34,000 Btu/h · Ducted | 2.26 | 65% | 8.6 | 15.2 | None | 1 | 218859487 |
| AE30H/O64PTRUST AIR CONDITIONERS · AE Serieswith ducted air handler AE30H/I64P | 2.5 tons30,000 Btu/h · Ducted | 1.98 | 71% | 9.2 | 17.6 | None | 1 | 218859486 |
| AE24H/O64PTRUST AIR CONDITIONERS · AE Serieswith ducted air handler AE24H/I64P | 2 tons23,000 Btu/h · Ducted | 1.78 | 71% | 8.7 | 16.4 | None | 1 | 218859485 |