ECO-AIR vs TRUST AIR CONDITIONERS heat pumps

Measured against models of the same size and duct type, ECO-AIR scores higher on 5 of the 6 ratings. ECO-AIR has 60 outdoor models, TRUST AIR CONDITIONERS has 60 outdoor models. ECO-AIR and TRUST AIR CONDITIONERS have no QMID on file and are not ranked. They share hardware: 39 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ECO-AIR and TRUST AIR CONDITIONERS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ECO-AIR scores higher on 5 of the 6 ratings.
  • ECO-AIR
  • TRUST AIR CONDITIONERS
  • Other ranked manufacturers
ECO-AIRTRUST AI…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingECO-AIRTRUST AIR CONDITIONERS
Efficiency index65% (higher)median —60% (higher)median —
COP at 5°F62% (higher)median 2.0059% (higher)median 2.00
Capacity retention at 5°F62% (higher)median 81%60% (higher)median 75%
HSPF274% (higher)median 9.971% (higher)median 10.0
SEER270% (higher)median 20.762% (higher)median 19.4
EER260% (higher)median 12.052% (higher)median 11.7
Heating capacity at 5°F65%median 25,100 Btu/h65%median 24,900 Btu/h
Outdoor models6060
AHRI certifications288177

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardECO-AIRTRUST AIR CONDITIONERS
CEE 2025 Tier 1 (Split ASHP)90%54 models83.3%50 models
CEE 2026 Tier 1 (Split ASHP)88.3%53 models81.7%49 models
CEE Advanced Tier (Split ASHP)1.7%1 models1.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)80%48 models73.3%44 models
DOE Cold Climate Heat Pump Challenge1.7%1 models1.7%1 models
ENERGY STAR Cold Climate81.7%49 models75%45 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • ECO-AIR
  • TRUST AIR CONDITIONERS
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeECO-AIRTRUST AIR CONDITIONERS
Ducted, up to 1.5 tons13 · index 76%12 · index 71%
Ducted, 2 tons6 · index 63%7 · index 58%
Ducted, 2.5 to 3 tons13 · index 66%14 · index 65%
Ducted, 3.5 to 4.5 tons14 · index 67%15 · index 62%
Ducted, 5 tons and up3 · index 64%3 · index 64%
Non-ducted, up to 1.5 tons18 · index 65%16 · index 62%
Non-ducted, 2 tons3 · index 66%5 · index 58%
Non-ducted, 2.5 to 3 tons13 · index 60%9 · index 56%
Non-ducted, 3.5 to 4.5 tons8 · index 60%10 · index 47%
Non-ducted, 5 tons and up2 · index 59%2 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeECO-AIRCold-climate score, best modelTRUST AIR CONDITIONERSCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)EDSO-06Hwith ducted air handler EDLS-06U12 of 13 models qualify · AHRI 21675995882.7(50 is the typical model of its size class)OAH18H/O6S4Pwith ducted air handler IUMDH18H/I63P10 of 12 models qualify · AHRI 217678082
Ducted, 2 tons85.8(50 is the typical model of its size class)EDSO-24Hwith ducted air handler EDHS-24U6 of 6 models qualify · AHRI 21675996885.8(50 is the typical model of its size class)OAH24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models qualify · AHRI 217678083
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)EDSO-36Hwith ducted air handler EDHS-36U11 of 13 models qualify · AHRI 21675996983.5(50 is the typical model of its size class)OAH36H/O6S4Pwith ducted air handler IUMDH36H/I63P11 of 14 models qualify · AHRI 217678084
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)EDMO-48HAlso sold as Eco Air EDMO-48H-6GX14 of 14 models qualify · AHRI 21676001082.6(50 is the typical model of its size class)M6H48HS/O6S4PAlso listed as M6H48HN/O6S4P15 of 15 models qualify · AHRI 217678130
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)None on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)EDSO-06Hwith ductless indoor unit EDWM-06U14 of 18 models qualify · AHRI 21675997994.9(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMC106H/I61P12 of 16 models qualify · AHRI 217678094
Non-ducted, 2 tons90.1(50 is the typical model of its size class)EDSO-24Hwith ductless indoor unit ED4W-24U3 of 3 models qualify · AHRI 21675994890.1(50 is the typical model of its size class)OAH24H/O6S4Pwith ductless indoor unit IUMC424H/I61P5 of 5 models qualify · AHRI 217678074
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class)EDMO-36HAlso sold as Eco Air EDMO-36H-5GX11 of 13 models qualify · AHRI 21676000889.4(50 is the typical model of its size class) (higher)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models qualify · AHRI 217678091
Non-ducted, 3.5 to 4.5 tons73.7(50 is the typical model of its size class) (higher)EDMO-48HAlso sold as Eco Air EDMO-48H-6GX8 of 8 models qualify · AHRI 21676001170.4(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P9 of 10 models qualify · AHRI 217678134
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeECO-AIRAll-around score, best modelTRUST AIR CONDITIONERSAll-around score, best model
Ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)EDSO-06Hwith ducted air handler EDLS-06U13 of 13 models have all five ratings · AHRI 21675995887.0(50 is the typical model of its size class)OAH09H/O6S4Pwith ducted air handler IUMDL09H/I63P12 of 12 models have all five ratings · AHRI 217678077
Ducted, 2 tons78.9(50 is the typical model of its size class)EDSO-24Ewith ducted air handler EDHS-24U6 of 6 models have all five ratings · AHRI 21675997578.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models have all five ratings · AHRI 217678110
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)EDMO-36HAlso sold as Eco Air EDMO-36H-5GX13 of 13 models have all five ratings · AHRI 21676000783.9(50 is the typical model of its size class)M5H36HS/O6S4PAlso listed as M5H36HN/O6S4P14 of 14 models have all five ratings · AHRI 217678127
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)EDMO-48EAlso sold as Eco Air EDMO-48E-6GX14 of 14 models have all five ratings · AHRI 21675999585.3(50 is the typical model of its size class)M6S48HS/O6S4PAlso listed as M6S48HN/O6S4P15 of 15 models have all five ratings · AHRI 217678145
Ducted, 5 tons and up65.9(50 is the typical model of its size class)EDSO-60Ewith ducted air handler EDHS-60U3 of 3 models have all five ratings · AHRI 21675997865.9(50 is the typical model of its size class)OUS60H/O6S4Pwith ducted air handler IUMDH60H/I63P3 of 3 models have all five ratings · AHRI 217678174
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)EDSO-06Hwith ductless indoor unit EDWM-06U18 of 18 models have all five ratings · AHRI 21675997994.5(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMW106H/I61P16 of 16 models have all five ratings · AHRI 217678065
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)EDSO-24Ewith ductless indoor unit EDWM-24U3 of 3 models have all five ratings · AHRI 21675993975.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ductless indoor unit IUMW124H/I61P5 of 5 models have all five ratings · AHRI 217678064
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)EDMO-36HAlso sold as Eco Air EDMO-36H-5GX13 of 13 models have all five ratings · AHRI 21676000667.1(50 is the typical model of its size class)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models have all five ratings · AHRI 217678091
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class) (higher)EDMO-48HAlso sold as Eco Air EDMO-48H-6GX8 of 8 models have all five ratings · AHRI 21676000962.6(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P10 of 10 models have all five ratings · AHRI 217678132
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class) (higher)EDMO-60EAlso sold as Eco Air EDMO-60E-6GX2 of 2 models have all five ratings · AHRI 21675999732.9(50 is the typical model of its size class)M6S60HS/O6S4PAlso listed as M6S60HN/O6S4P2 of 2 models have all five ratings · AHRI 217678177

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingECO-AIRTRUST AIR CONDITIONERS
COP at 5°Fbeats 99% · 2.54EDSO-24ENon-ducted, 2 tonsbeats 99% · 2.51OUS12H/O6S4PNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 120%EDSO-09HDucted, up to 1.5 tonsbeats 98% · 120%OAH09H/O6S4PDucted, up to 1.5 tons
HSPF2beats 99% · 14.8EDSO-06HNon-ducted, up to 1.5 tonsbeats 99% · 11.0M6H48HS/O6S4PAlso listed as M6H48HN/O6S4PDucted, 3.5 to 4.5 tons
SEER2beats 97% · 25.0EDMO-27EAlso sold as Eco Air EDMO-27E-4GXNon-ducted, 2.5 to 3 tonsbeats 96% · 20.4M6H48HS/O6S4PAlso listed as M6H48HN/O6S4PDucted, 3.5 to 4.5 tons
EER2beats 99% · 18.0EDSO-06HNon-ducted, up to 1.5 tonsbeats 96% · 16.0OUS06H/O6S4PNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 39,000 Btu/hECUO-36HDucted, 2.5 to 3 tonsbeats 98% · 39,500 Btu/hOAH36H/O6S4PNon-ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ECO-AIR vs TRUST AIR CONDITIONERS: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ECO-AIR (median, middle 50%)
  • TRUST AIR CONDITIONERS (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
ECO-AIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ECO-AIR, 47°F60100%100%100%100%100%
ECO-AIR, 17°F6067%70%74%82%86%
ECO-AIR, 5°F6058%62%70%79%82%
ECO-AIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ECO-AIR, 47°F602.973.093.253.533.74
ECO-AIR, 17°F602.032.222.362.542.65
ECO-AIR, 5°F601.91.9822.112.33
TRUST AIR CONDITIONERS: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F60100%100%100%100%100%
TRUST AIR CONDITIONERS, 17°F6063%69%73%81%85%
TRUST AIR CONDITIONERS, 5°F6059%63%66%78%83%
TRUST AIR CONDITIONERS: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F602.873.13.283.513.74
TRUST AIR CONDITIONERS, 17°F602.092.212.282.492.6
TRUST AIR CONDITIONERS, 5°F601.851.9622.12.26

Source: NEEP ccASHP list · as of