Skip to content

Cooper&Hunter vs TRUST AIR CONDITIONERS heat pumps

Measured against models of the same size and duct type, Cooper&Hunter scores higher on 5 of the 6 ratings. Cooper&Hunter has 63 outdoor models, TRUST AIR CONDITIONERS has 60 outdoor models. TRUST AIR CONDITIONERS has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Cooper&Hunter and TRUST AIR CONDITIONERS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Cooper&Hunter scores higher on 5 of the 6 ratings.
  • Cooper&Hunter
  • TRUST AIR CONDITIONERS
  • Other ranked manufacturers
Cooper&H…TRUST AI…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCooper&HunterTRUST AIR CONDITIONERS
Efficiency index65% (higher)median — · 1st ranked60% (higher)median —
COP at 5°F66% (higher)median 2.10 · 3rd ranked59% (higher)median 2.00
Capacity retention at 5°F63% (higher)median 81% · 5th ranked60% (higher)median 75%
HSPF274% (higher)median 10.2 · 1st ranked71% (higher)median 10.0
SEER266% (higher)median 21.0 · 2nd ranked62% (higher)median 19.4
EER259% (higher)median 12.0 · 9th ranked52% (higher)median 11.7
Heating capacity at 5°F65%median 24,000 Btu/h · 5th ranked65%median 24,900 Btu/h
Outdoor models6360
AHRI certifications279177

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCooper&HunterTRUST AIR CONDITIONERS
CEE 2025 Tier 1 (Split ASHP)85.7%54 models83.3%50 models
CEE 2026 Tier 1 (Split ASHP)84.1%53 models81.7%49 models
CEE Advanced Tier (Split ASHP)7.9%5 models1.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)73%46 models73.3%44 models
DOE Cold Climate Heat Pump Challenge7.9%5 models1.7%1 models
ENERGY STAR Cold Climate71.4%45 models75%45 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Cooper&Hunter
  • TRUST AIR CONDITIONERS
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCooper&HunterTRUST AIR CONDITIONERS
Ducted, up to 1.5 tons12 · index 74%12 · index 71%
Ducted, 2 tons6 · index 62%7 · index 58%
Ducted, 2.5 to 3 tons15 · index 67%14 · index 65%
Ducted, 3.5 to 4.5 tons14 · index 67%15 · index 62%
Ducted, 5 tons and up3 · index 67%3 · index 64%
Non-ducted, up to 1.5 tons20 · index 67%16 · index 62%
Non-ducted, 2 tons4 · index 61%5 · index 58%
Non-ducted, 2.5 to 3 tons13 · index 63%9 · index 56%
Non-ducted, 3.5 to 4.5 tons11 · index 50%10 · index 47%
Non-ducted, 5 tons and up2 · index 71%2 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCooper&HunterCold-climate score, best modelTRUST AIR CONDITIONERSCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 21586421282.7(50 is the typical model of its size class)OAH18H/O6S4Pwith ducted air handler IUMDH18H/I63P10 of 12 models qualify · AHRI 217678082
Ducted, 2 tons85.8(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 21586421985.8(50 is the typical model of its size class)OAH24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models qualify · AHRI 217678083
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 21702655283.5(50 is the typical model of its size class)OAH36H/O6S4Pwith ducted air handler IUMDH36H/I63P11 of 14 models qualify · AHRI 217678084
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 21586427982.6(50 is the typical model of its size class)M6H48HS/O6S4PAlso listed as M6H48HN/O6S4P15 of 15 models qualify · AHRI 217678130
Ducted, 5 tons and up88.6(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558None on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 21586417294.9(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMC106H/I61P12 of 16 models qualify · AHRI 217678094
Non-ducted, 2 tons90.1(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 21586419190.1(50 is the typical model of its size class)OAH24H/O6S4Pwith ductless indoor unit IUMC424H/I61P5 of 5 models qualify · AHRI 217678074
Non-ducted, 2.5 to 3 tons93.3(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 21702655389.4(50 is the typical model of its size class)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models qualify · AHRI 217678091
Non-ducted, 3.5 to 4.5 tons94.7(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 21702655670.4(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P9 of 10 models qualify · AHRI 217678134
Non-ducted, 5 tons and up98.3(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCooper&HunterAll-around score, best modelTRUST AIR CONDITIONERSAll-around score, best model
Ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 21586421287.0(50 is the typical model of its size class)OAH09H/O6S4Pwith ducted air handler IUMDL09H/I63P12 of 12 models have all five ratings · AHRI 217678077
Ducted, 2 tons78.9(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 21586422878.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ducted air handler IUMDH24H/I63P7 of 7 models have all five ratings · AHRI 217678110
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 21586427683.9(50 is the typical model of its size class)M5H36HS/O6S4PAlso listed as M5H36HN/O6S4P14 of 14 models have all five ratings · AHRI 217678127
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 21586426485.3(50 is the typical model of its size class)M6S48HS/O6S4PAlso listed as M6S48HN/O6S4P15 of 15 models have all five ratings · AHRI 217678145
Ducted, 5 tons and up70.8(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 21702655865.9(50 is the typical model of its size class)OUS60H/O6S4Pwith ducted air handler IUMDH60H/I63P3 of 3 models have all five ratings · AHRI 217678174
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 21586417294.5(50 is the typical model of its size class)OUS06H/O6S4Pwith ductless indoor unit IUMW106H/I61P16 of 16 models have all five ratings · AHRI 217678065
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 21586417175.9(50 is the typical model of its size class)OUS24H/O6S4Pwith ductless indoor unit IUMW124H/I61P5 of 5 models have all five ratings · AHRI 217678064
Non-ducted, 2.5 to 3 tons87.2(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 21702655367.1(50 is the typical model of its size class)OAH36H/O6S4Pwith ductless indoor unit IUMFC36H/I61P9 of 9 models have all five ratings · AHRI 217678091
Non-ducted, 3.5 to 4.5 tons82.5(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 21702655662.6(50 is the typical model of its size class)M6H60HS/O6S4PAlso listed as M6H60HN/O6S4P10 of 10 models have all five ratings · AHRI 217678132
Non-ducted, 5 tons and up83.7(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 21702655932.9(50 is the typical model of its size class)M6S60HS/O6S4PAlso listed as M6S60HN/O6S4P2 of 2 models have all five ratings · AHRI 217678177

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCooper&HunterTRUST AIR CONDITIONERS
COP at 5°Fbeats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5 to 4.5 tonsbeats 99% · 2.51OUS12H/O6S4PNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and upbeats 98% · 120%OAH09H/O6S4PDucted, up to 1.5 tons
HSPF2beats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 99% · 11.0M6H48HS/O6S4PAlso listed as M6H48HN/O6S4PDucted, 3.5 to 4.5 tons
SEER2beats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5 to 3 tonsbeats 96% · 20.4M6H48HS/O6S4PAlso listed as M6H48HN/O6S4PDucted, 3.5 to 4.5 tons
EER2beats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 96% · 16.0OUS06H/O6S4PNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and upbeats 98% · 39,500 Btu/hOAH36H/O6S4PNon-ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Cooper&Hunter vs TRUST AIR CONDITIONERS: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Cooper&Hunter (median, middle 50%)
  • TRUST AIR CONDITIONERS (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity2.102.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
Cooper&Hunter: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F63100%100%100%100%100%
Cooper&Hunter, 17°F6368%73%77%83%90%
Cooper&Hunter, 5°F6358%63%70%81%89%
Cooper&Hunter: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F632.923.13.33.583.82
Cooper&Hunter, 17°F632.122.212.312.522.69
Cooper&Hunter, 5°F631.922.12.22.35
TRUST AIR CONDITIONERS: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F60100%100%100%100%100%
TRUST AIR CONDITIONERS, 17°F6063%69%73%81%85%
TRUST AIR CONDITIONERS, 5°F6059%63%66%78%83%
TRUST AIR CONDITIONERS: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F602.873.13.283.513.74
TRUST AIR CONDITIONERS, 17°F602.092.212.282.492.6
TRUST AIR CONDITIONERS, 5°F601.851.9622.12.26

Source: NEEP ccASHP list · as of