Skip to content

Cooper&Hunter vs LPS Legacy heat pumps

Measured against models of the same size and duct type, Cooper&Hunter scores higher on 6 of the 6 ratings. Cooper&Hunter has 63 outdoor models, LPS Legacy has 65 outdoor models. LPS Legacy has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Cooper&Hunter and LPS Legacy on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Cooper&Hunter scores higher on 6 of the 6 ratings.
  • Cooper&Hunter
  • LPS Legacy
  • Other ranked manufacturers
Cooper&H…LPS Lega…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCooper&HunterLPS Legacy
Efficiency index65% (higher)median — · 1st ranked62% (higher)median —
COP at 5°F66% (higher)median 2.10 · 3rd ranked62% (higher)median 2.00
Capacity retention at 5°F63% (higher)median 81% · 5th ranked60% (higher)median 78%
HSPF274% (higher)median 10.2 · 1st ranked70% (higher)median 9.9
SEER266% (higher)median 21.0 · 2nd ranked63% (higher)median 19.5
EER259% (higher)median 12.0 · 9th ranked56% (higher)median 11.7
Heating capacity at 5°F65% (higher)median 24,000 Btu/h · 5th ranked62% (higher)median 19,600 Btu/h
Outdoor models6365
AHRI certifications279201

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCooper&HunterLPS Legacy
CEE 2025 Tier 1 (Split ASHP)85.7%54 models83.1%54 models
CEE 2026 Tier 1 (Split ASHP)84.1%53 models81.5%53 models
CEE Advanced Tier (Split ASHP)7.9%5 models4.6%3 models
Xcel Energy Colorado cold-climate ASHP (2025)73%46 models73.8%48 models
DOE Cold Climate Heat Pump Challenge7.9%5 models4.6%3 models
ENERGY STAR Cold Climate71.4%45 models73.8%48 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Cooper&Hunter
  • LPS Legacy
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCooper&HunterLPS Legacy
Ducted, up to 1.5 tons12 · index 74%11 · index 78%
Ducted, 2 tons6 · index 62%6 · index 72%
Ducted, 2.5 to 3 tons15 · index 67%13 · index 64%
Ducted, 3.5 to 4.5 tons14 · index 67%10 · index 67%
Ducted, 5 tons and up3 · index 67%2 · index 65%
Non-ducted, up to 1.5 tons20 · index 67%25 · index 60%
Non-ducted, 2 tons4 · index 61%7 · index 57%
Non-ducted, 2.5 to 3 tons13 · index 63%12 · index 51%
Non-ducted, 3.5 to 4.5 tons11 · index 50%8 · index 44%
Non-ducted, 5 tons and up2 · index 71%1 · index 62%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCooper&HunterCold-climate score, best modelLPS LegacyCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 21586421293.7(50 is the typical model of its size class)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK10 of 11 models qualify · AHRI 215324834
Ducted, 2 tons85.8(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 21586421985.8(50 is the typical model of its size class)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models qualify · AHRI 215324857
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 21702655283.6(50 is the typical model of its size class)D5CMHAH36EAK9 of 13 models qualify · AHRI 215357623
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 21586427982.6(50 is the typical model of its size class)D5CMHAH48FAK10 of 10 models qualify · AHRI 215357626
Ducted, 5 tons and up88.6(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 21586417297.1(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK17 of 25 models qualify · AHRI 215413354
Non-ducted, 2 tons90.1(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 21586419190.1(50 is the typical model of its size class)D5CSHAH24AAKwith ductless indoor unit D5FSCAH24XAK7 of 7 models qualify · AHRI 215324855
Non-ducted, 2.5 to 3 tons93.3(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 21702655389.4(50 is the typical model of its size class)D5CLHAH36AAKwith ductless indoor unit D5FCFAH36XAK8 of 12 models qualify · AHRI 215324890
Non-ducted, 3.5 to 4.5 tons94.7(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 21702655675.6(50 is the typical model of its size class)D5CMHAH48FAK7 of 8 models qualify · AHRI 215357627
Non-ducted, 5 tons and up98.3(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCooper&HunterAll-around score, best modelLPS LegacyAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 21586421295.7(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK11 of 11 models have all five ratings · AHRI 215324834
Ducted, 2 tons78.9(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 21586422880.3(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models have all five ratings · AHRI 215324857
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 21586427685.6(50 is the typical model of its size class) (higher)D5CMHAH30EAK13 of 13 models have all five ratings · AHRI 215357620
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 21586426486.0(50 is the typical model of its size class) (higher)D5CMRAH48FAK10 of 10 models have all five ratings · AHRI 215357647
Ducted, 5 tons and up70.8(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 21702655866.4(50 is the typical model of its size class)D5CLRAH58AAKwith ducted air handler D5FLDAH58XHK2 of 2 models have all five ratings · AHRI 215324904
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 21586417296.9(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK25 of 25 models have all five ratings · AHRI 215324832
Non-ducted, 2 tons87.8(50 is the typical model of its size class)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 21586417189.4(50 is the typical model of its size class) (higher)D5CSRAH24AAKwith ductless indoor unit D5FPHAH18XAK7 of 7 models have all five ratings · AHRI 215324879
Non-ducted, 2.5 to 3 tons87.2(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 21702655385.8(50 is the typical model of its size class)D5CMHAH30EAK12 of 12 models have all five ratings · AHRI 215357619
Non-ducted, 3.5 to 4.5 tons82.5(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 21702655676.6(50 is the typical model of its size class)D5CMHAH48FAK8 of 8 models have all five ratings · AHRI 215357625
Non-ducted, 5 tons and up83.7(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 21702655961.8(50 is the typical model of its size class)D5CMRAH55FAK1 of 1 models have all five ratings · AHRI 215357649

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCooper&HunterLPS Legacy
COP at 5°Fbeats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5 to 4.5 tonsbeats 99% · 2.51D5CSRAH12AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and upbeats 100% · 150%D5CPRAH06AAKNon-ducted, up to 1.5 tons
HSPF2beats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 100% · 15.6D5CPRAH06AAKNon-ducted, up to 1.5 tons
SEER2beats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5 to 3 tonsbeats 99% · 33.1D5CPRAH06AAKNon-ducted, up to 1.5 tons
EER2beats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 100% · 14.5D5CSHAH06AAKDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and upbeats 99% · 22,600 Btu/hD5CPRAH18AANon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Cooper&Hunter vs LPS Legacy: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Cooper&Hunter (median, middle 50%)
  • LPS Legacy (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity2.102.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Cooper&Hunter: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F63100%100%100%100%100%
Cooper&Hunter, 17°F6368%73%77%83%90%
Cooper&Hunter, 5°F6358%63%70%81%89%
Cooper&Hunter: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F632.923.13.33.583.82
Cooper&Hunter, 17°F632.122.212.312.522.69
Cooper&Hunter, 5°F631.922.12.22.35
LPS Legacy: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
LPS Legacy, 47°F65100%100%100%100%100%
LPS Legacy, 17°F6564%68%73%79%85%
LPS Legacy, 5°F6557%61%66%78%82%
LPS Legacy: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
LPS Legacy, 47°F652.893.13.223.493.59
LPS Legacy, 17°F652.072.222.342.452.59
LPS Legacy, 5°F651.89222.142.34

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter