Skip to content

LPS Legacy heat pump efficiency: 65 outdoor models compared

LPS Legacy has 65 heat pump outdoor models certified with this refrigerant group, in 201 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LPS Legacy makes. LPS Legacy has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
65
AHRI certifications
201
Efficiency index
62%
Typical model vs same-size, same-type peers (95 models)
Meet CEE 2025
83.1%
54 models

How LPS Legacy compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
LPS Legacy against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of LPS Legacy’s own modelsLPS Legacy is strongest on HSPF2 (its typical model beats 70% of comparable models) and weakest on EER2 (56%).
  • LPS Legacy
  • Middle half of its models
  • Other ranked manufacturers
LPS Lega…

Source: AHRI Directory, NEEP · as of

Average peer percentile of LPS Legacy’s models
RatingBeats comparable modelsRankRaw median
Efficiency index95 models scored62%Not ranked—
COP at 5°F95 models scored62%Not ranked2.00
Capacity retention at 5°F95 models scored60%Not ranked78%
HSPF295 models scored70%Not ranked9.9
SEER295 models scored63%Not ranked19.5
EER295 models scored56%Not ranked11.7
Heating capacity at 5°F95 models scored62%Not ranked19,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
LPS Legacy’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • LPS Legacy (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1178%78%87%80%
Ducted, 2 tons672%59%85%76%
Ducted, 2.5 to 3 tons1364%59%78%68%
Ducted, 3.5 to 4.5 tons1067%52%83%72%
Ducted, 5 tons and up265%79%93%82%
Non-ducted, up to 1.5 tons2560%69%64%60%
Non-ducted, 2 tons757%69%52%54%
Non-ducted, 2.5 to 3 tons1251%52%54%51%
Non-ducted, 3.5 to 4.5 tons844%44%59%38%
Non-ducted, 5 tons and up162%79%65%77%

Every LPS Legacy model in the market

LPS Legacy’s 95 models with a known size and duct type, over the shape of the whole catalog.
LPS Legacy models by size and ratingColoured: LPS Legacy · grey shapes: all 15,936 models · lines: catalog medians by size
  • LPS Legacy models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 95 lps legacy models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

LPS Legacy in the cold

From NEEP’s cold-climate listings: 65 LPS Legacy models against all 6,343 listed models.
LPS Legacy capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical LPS Legacy model keeps 66% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • LPS Legacy (median, middle 50%)
Heating capacity, % of its 47°F maximum66%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
LPS Legacy: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
LPS Legacy, 47°F65100%100%100%100%100%
LPS Legacy, 17°F6564%68%73%79%85%
LPS Legacy, 5°F6557%61%66%78%82%
LPS Legacy: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
LPS Legacy, 47°F652.893.13.223.493.59
LPS Legacy, 17°F652.072.222.342.452.59
LPS Legacy, 5°F651.89222.142.34

Source: NEEP ccASHP list · as of

Top LPS Legacy models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 LPS Legacy cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1D5CPRAH18AALPS Legacy · D5F Serieswith ductless indoor unit D5FPHAH18XAK1.5 tons18,000 Btu/h · Non-ducted113%2.3415.222,60024.5CEE 25CEE 26CEE AdvXcelDOEES CC1215413354Non-ducted, up to 1.5 tons97.1
2D5CSHAH06AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FSHAH06XAK0.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.7CEE 25CEE 26CEE AdvXcelDOEES CC3215324832Non-ducted, up to 1.5 tons97.0
3D5CSHAH06AAKLPS Legacy · D5F Serieswith ducted air handler D5FSDAH06XAK0.5 tons6,500 Btu/h · Ducted98%2.4113.87,80021.5CEE 25CEE 26XcelES CC3215324834Ducted, up to 1.5 tons93.7
4D5CSRAH09AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FSFAH09XAK1 ton9,000 Btu/h · Non-ducted96%2.2713.98,60026.0CEE 25CEE 26XcelES CC6215324863Non-ducted, up to 1.5 tons90.4
5D5CSHAH24AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FSCAH24XAK2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.8CEE 25CEE 26XcelES CC5215324855Non-ducted, 2 tons90.1

All-around best

Top 5 LPS Legacy models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1D5CSHAH06AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FSHAH06XAK0.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.718.0CEE 25CEE 26CEE AdvXcelDOEES CC3215324832Non-ducted, up to 1.5 tons96.997.096.797.0
2D5CSHAH06AAKLPS Legacy · D5F Serieswith ducted air handler D5FSDAH06XAK0.5 tons6,500 Btu/h · Ducted98%2.4113.821.514.5CEE 25CEE 26XcelES CC3215324834Ducted, up to 1.5 tons95.793.797.793.7
3D5CSRAH09AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FSFAH09XAK1 ton9,000 Btu/h · Non-ducted96%2.2713.926.016.3CEE 25CEE 26XcelES CC6215324863Non-ducted, up to 1.5 tons93.390.496.290.4
4D5CPRAH06AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FPHAH06XAK0.5 tons6,000 Btu/h · Non-ducted150%2.0015.633.116.5CEE 25CEE 26XcelES CC1215413351Non-ducted, up to 1.5 tons93.288.098.488.0
5D5CPRAH09AAKLPS Legacy · D5F Serieswith ductless indoor unit D5FPHAH09XAK1 ton9,000 Btu/h · Non-ducted113%2.0014.631.516.0CEE 25CEE 26XcelES CC1215413352Non-ducted, up to 1.5 tons92.286.597.986.5

Best model on each rating

LPS Legacy’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FD5CSRAH12AAK2.51Non-ducted, up to 1.5 tons99%215324869
Capacity retention at 5°FD5CPRAH06AAK150%Non-ducted, up to 1.5 tons100%215413351
HSPF2D5CPRAH06AAK15.6Non-ducted, up to 1.5 tons100%215413351
SEER2D5CPRAH06AAK33.1Non-ducted, up to 1.5 tons99%215413351
EER2D5CSHAH06AAK14.5Ducted, up to 1.5 tons100%215324834
Heating capacity at 5°FD5CPRAH18AA22,600 Btu/hNon-ducted, up to 1.5 tons99%215413354

All 65 LPS Legacy models in Explore

LPS Legacy size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
LPS Legacy: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK10 of 11 models qualify · AHRI 21532483495.7(50 is the typical model of its size class)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK11 of 11 models have all five ratings · AHRI 215324834
Ducted, 2 tons85.8(50 is the typical model of its size class)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models qualify · AHRI 21532485780.3(50 is the typical model of its size class)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models have all five ratings · AHRI 215324857
Ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class)D5CMHAH36EAK9 of 13 models qualify · AHRI 21535762385.6(50 is the typical model of its size class)D5CMHAH30EAK13 of 13 models have all five ratings · AHRI 215357620
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)D5CMHAH48FAK10 of 10 models qualify · AHRI 21535762686.0(50 is the typical model of its size class)D5CMRAH48FAK10 of 10 models have all five ratings · AHRI 215357647
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)66.4(50 is the typical model of its size class)D5CLRAH58AAKwith ducted air handler D5FLDAH58XHK2 of 2 models have all five ratings · AHRI 215324904
Non-ducted, up to 1.5 tons97.1(50 is the typical model of its size class)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK17 of 25 models qualify · AHRI 21541335496.9(50 is the typical model of its size class)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK25 of 25 models have all five ratings · AHRI 215324832
Non-ducted, 2 tons90.1(50 is the typical model of its size class)D5CSHAH24AAKwith ductless indoor unit D5FSCAH24XAK7 of 7 models qualify · AHRI 21532485589.4(50 is the typical model of its size class)D5CSRAH24AAKwith ductless indoor unit D5FPHAH18XAK7 of 7 models have all five ratings · AHRI 215324879
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)D5CLHAH36AAKwith ductless indoor unit D5FCFAH36XAK8 of 12 models qualify · AHRI 21532489085.8(50 is the typical model of its size class)D5CMHAH30EAK12 of 12 models have all five ratings · AHRI 215357619
Non-ducted, 3.5 to 4.5 tons75.6(50 is the typical model of its size class)D5CMHAH48FAK7 of 8 models qualify · AHRI 21535762776.6(50 is the typical model of its size class)D5CMHAH48FAK8 of 8 models have all five ratings · AHRI 215357625
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)61.8(50 is the typical model of its size class)D5CMRAH55FAK1 of 1 models have all five ratings · AHRI 215357649

All-around board, every manufacturer

Newest LPS Legacy certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified LPS Legacy outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
D5CURAH30AAKLPS Legacy · D5C Serieswith ducted air handler D5MUWAQ30XA32.5 tons30,000 Btu/h · Ducted1.9960%8.718.6CEE 25CEE 265218213821
D5CURAH18AAKLPS Legacy · D5C Serieswith ducted air handler D5MUWAQ18XA31.5 tons18,000 Btu/h · Ducted2.1063%9.418.5CEE 25CEE 264218213820
D5CURAH36AAKLPS Legacy · D5C Serieswith ducted air handler D5MUWAQ36XA33 tons36,000 Btu/h · Ducted1.9979%9.316.7CEE 25CEE 26XcelES CC5218213795
D5CURAH24AAKLPS Legacy · D5C Serieswith ducted air handler D5MUWAQ24XA32 tons24,000 Btu/h · Ducted1.9678%10.417.4CEE 25CEE 26XcelES CC4218213794
D5CUHAH36AAKLPS Legacy · D5C Serieswith ducted air handler D5MUWAQ36XA33 tons36,000 Btu/h · Ducted1.8094%9.616.8CEE 25CEE 26XcelES CC6218213793

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare LPS Legacy

Manufacturers of a similar size, side by side.

LPS Legacy includes these brand names as listed in AHRI: LPS Legacy. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy