Skip to content

TCL heat pump efficiency: 192 outdoor models compared

TCL has 192 heat pump outdoor models certified with this refrigerant group, in 701 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TCL makes. TCL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
192
AHRI certifications
701
Efficiency index
50%
Typical model vs same-size, same-type peers (210 models)
Meet CEE 2025
75%
144 models

How TCL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TCL against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of TCL’s own modelsTCL is strongest on SEER2 (its typical model beats 59% of comparable models) and weakest on COP at 5°F (36%).
  • TCL
  • Middle half of its models
  • Other ranked manufacturers
TCL

Source: AHRI Directory, NEEP · as of

Average peer percentile of TCL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index210 models scored50%Not ranked—
COP at 5°F211 models scored36%Not ranked1.89
Capacity retention at 5°F210 models scored52%Not ranked75%
HSPF2221 models scored53%Not ranked9.5
SEER2221 models scored59%Not ranked20.0
EER2221 models scored41%Not ranked11.2
Heating capacity at 5°F210 models scored52%Not ranked17,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TCL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • TCL (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1259%44%50%81%
Ducted, 2 tons1249%33%65%59%
Ducted, 2.5 to 3 tons2158%26%74%77%
Ducted, 3.5 to 4.5 tons2250%27%67%70%
Non-ducted, up to 1.5 tons9550%35%50%52%
Non-ducted, 2 tons2043%43%47%47%
Non-ducted, 2.5 to 3 tons2948%51%47%55%
Non-ducted, 3.5 to 4.5 tons1246%32%28%77%

Every TCL model in the market

TCL’s 223 models with a known size and duct type, over the shape of the whole catalog.
TCL models by size and ratingColoured: TCL · grey shapes: all 15,936 models · lines: catalog medians by size
  • TCL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 223 tcl models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

TCL in the cold

From NEEP’s cold-climate listings: 110 TCL models against all 6,343 listed models.
TCL capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical TCL model keeps 70% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • TCL (median, middle 50%)
Heating capacity, % of its 47°F maximum70%COP at maximum capacity1.90

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
TCL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TCL, 47°F110100%100%100%100%100%
TCL, 17°F11067%72%74%82%92%
TCL, 5°F11058%65%70%72%77%
TCL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TCL, 47°F1102.52.83.013.53.71
TCL, 17°F1101.992.092.22.32.47
TCL, 5°F1101.81.81.922.03

Source: NEEP ccASHP list · as of

Top TCL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 TCL cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1TMH18HEI2NAS0U25TCL · free match 27SAlso listed as H18FMHD3XPC, TMH18HEI2NAS0U251.5 tons20,000 Btu/h · Non-ducted99%2.0010.019,80027.0CEE 25CEE 26XcelES CC1218028413Non-ducted, up to 1.5 tons72.4
2TMH18HEI2NAO0U24TCL · TUM241.5 tons18,000 Btu/h · Non-ducted80%2.0010.516,00024.0CEE 25CEE 26XcelES CC3215351193Non-ducted, up to 1.5 tons70.1
3H24TDHXPCTCL · Front returnwith ducted air handler H24FAHUDE2 tons24,000 Btu/h · Ducted125%1.909.530,00017.0CEE 25CEE 26XcelES CC1218332483Ducted, 2 tons69.6
4H48SDH20XQCTCL · Apex XS Series Unitary HPwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H264 tons48,000 Btu/h · Ducted100%1.859.548,00018.0CEE 25CEE 26XcelES CC1218453819Ducted, 3.5 to 4.5 tons69.4
5H24SDH20XQCTCL · Apex XS Series Unitary HPwith ducted air handler H24APH20UDEAlso listed as THH24HDI2NAJ0H262 tons24,000 Btu/h · Ducted100%1.8510.024,00019.0CEE 25CEE 26XcelES CC1218453815Ducted, 2 tons68.8

All-around best

Top 5 TCL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1TMH18HEI2NAS0U25TCL · free match 27SAlso listed as H18FMHD3XPC, TMH18HEI2NAS0U251.5 tons20,000 Btu/h · Non-ducted99%2.0010.027.015.0CEE 25CEE 26XcelES CC1218028413Non-ducted, up to 1.5 tons83.772.494.972.4
2TMH27HEI2NAS0U25TCL · free match 27SAlso listed as H27FMHD4XPC, TMH27HEI2NAS0U252.5 tons27,000 Btu/h · Non-ducted96%2.0010.526.514.0CEE 25CEE 26XcelES CC1218028414Non-ducted, 2.5 to 3 tons83.468.798.168.7
3TMH27HEI2NAS0U25*TCL · free match 27S HTAlso listed as H27FMHD4XPC2.5 tons27,000 Btu/h · Ducted96%1.7510.522.012.5CEE 25CEE 26XcelES CC3218625047Ducted, 2.5 to 3 tons80.664.496.964.4
4TSH09HEI2NAP0T24UTCL · T-Pro-25ESwith ductless indoor unit TSH09IEI2NAO0T24U1 ton9,000 Btu/h · Non-ducted106%1.8010.525.014.5CEE 25CEE 26XcelES CC1216506195Non-ducted, up to 1.5 tons77.364.989.764.9
5TMH36HEI2NAS0U25TCL · free match 27SAlso listed as H36FMHD5XPC, TMH36HEI2NAS0U253 tons36,000 Btu/h · Non-ducted83%2.0010.025.013.6CEE 25CEE 26XcelES CC1218028415Non-ducted, 2.5 to 3 tons76.958.695.158.6

Best model on each rating

TCL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FTSH24HDI2NAL0B25Also listed as H24SVH20XQC2.25Non-ducted, 2 tons88%217603531
Capacity retention at 5°FH24TDHXPC125%Ducted, 2 tons99%218332483
HSPF2TMH36HEI2NAM5U24Also listed as H36FMH21XPC10.5Ducted, 2.5 to 3 tons96%215351199
SEER2TMH27HEI2NAS0U25*Also listed as H27FMHD4XPC22.0Ducted, 2.5 to 3 tons100%218625047
EER2TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2514.0Non-ducted, 2.5 to 3 tons97%218028414
Heating capacity at 5°FH24TDHXPC30,000 Btu/hDucted, 2 tons99%218332483

All 192 TCL models in Explore

TCL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TCL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons68.6(50 is the typical model of its size class)THH18TEI2NAG0F24with ducted air handler THH18IEI2NAG0F24Also listed as H18TDHXPC12 of 12 models qualify · AHRI 21808309173.5(50 is the typical model of its size class)TMH18HEI2NAS0U25*Also listed as H18FMHD3XPC12 of 12 models have all five ratings · AHRI 218625046
Ducted, 2 tons69.6(50 is the typical model of its size class)H24TDHXPCwith ducted air handler H24FAHUDE11 of 12 models qualify · AHRI 21833248370.1(50 is the typical model of its size class)H24SDH20XQCwith ducted air handler H24APH20UDEAlso listed as THH24HDI2NAJ0H2614 of 14 models have all five ratings · AHRI 218453815
Ducted, 2.5 to 3 tons67.2(50 is the typical model of its size class)THH30TEI2NAG0F24with ducted air handler THH30IEI2NAG0F24Also listed as H30TDHXPC19 of 21 models qualify · AHRI 21808287780.6(50 is the typical model of its size class)TMH27HEI2NAS0U25*Also listed as H27FMHD4XPC19 of 19 models have all five ratings · AHRI 218625047
Ducted, 3.5 to 4.5 tons69.4(50 is the typical model of its size class)H48SDH20XQCwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H2622 of 22 models qualify · AHRI 21845381966.2(50 is the typical model of its size class)TMH42HDI2NAO0U25Also listed as TMH42HDI2NAO0U2522 of 22 models have all five ratings · AHRI 218467786
Non-ducted, up to 1.5 tons72.4(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2571 of 95 models qualify · AHRI 21802841383.7(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2585 of 96 models have all five ratings · AHRI 218028413
Non-ducted, 2 tons63.4(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC12 of 21 models qualify · AHRI 21808286467.0(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC18 of 19 models have all five ratings · AHRI 218082864
Non-ducted, 2.5 to 3 tons68.7(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2519 of 28 models qualify · AHRI 21802841483.4(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2528 of 29 models have all five ratings · AHRI 218028414
Non-ducted, 3.5 to 4.5 tons48.5(50 is the typical model of its size class)TMH48HEI2NAS0U2511 of 12 models qualify · AHRI 21802841670.2(50 is the typical model of its size class)TMH48HEI2NAS0U2512 of 12 models have all five ratings · AHRI 218028416

All-around board, every manufacturer

Newest TCL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TCL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
H24SUH23XGCTCL · ULTIMATE BREEZEINwith ductless indoor unit H24SBH20XPE2 tons23,000 Btu/h · Non-ducted1.8074%9.523.0CEE 25CEE 26XcelES CC2218749568
TH36SEH19XWC*TCLwith ductless indoor unit TH36SEH19XWE3 tons36,000 Btu/h · Non-ducted2.1057%9.019.0None1218748223
H60TDH16XACTCL · Advantage Auto Voltwith ducted air handler H60APH20UDE4.5 tons53,000 Btu/h · Ducted1.8072%8.517.0ES CC2218736937
H48TDH18XACTCL · Advantage Auto Voltwith ducted air handler H48APH20UDE4 tons47,000 Btu/h · Ducted1.8070%9.018.0ES CC2218736936
H36TDH18XACTCL · Advantage Auto Voltwith ducted air handler H36APH20UDE3 tons36,000 Btu/h · Ducted1.9072%9.019.0CEE 25CEE 26XcelES CC3218736935

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare TCL

Manufacturers of a similar size, side by side.

TCL includes these brand names as listed in AHRI: TCL. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter