Friedrich vs TCL heat pumps
Measured against models of the same size and duct type, TCL scores higher on 5 of the 6 ratings. Friedrich has 188 outdoor models, TCL has 177 outdoor models. TCL has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- TCL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | TCL |
|---|---|---|
| Efficiency index | 39%median — · 28th ranked | 49%median — |
| COP at 5°F | 46% (higher)median 1.99 · 22nd ranked | 36% (higher)median 1.89 |
| Capacity retention at 5°F | 36%median 52% · 26th ranked | 50%median 75% |
| HSPF2 | 31%median 7.5 · 28th ranked | 52%median 9.5 |
| SEER2 | 34%median 15.2 · 28th ranked | 59%median 20.0 |
| EER2 | 37%median 10.6 · 27th ranked | 41%median 11.2 |
| Heating capacity at 5°F | 35%median 17,000 Btu/h · 28th ranked | 51%median 17,000 Btu/h |
| Outdoor models | 188 | 177 |
| AHRI certifications | 6,657 | 636 |
Share of models meeting each standard
| Standard | Friedrich | TCL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 26.6%50 models | 75.7%134 models |
| CEE 2026 Tier 1 (Split ASHP) | 23.9%45 models | 75.7%134 models |
| CEE Advanced Tier (Split ASHP) | 0.5%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.3%40 models | 72.3%128 models |
| DOE Cold Climate Heat Pump Challenge | 0.5%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 22.3%42 models | 64.4%114 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- TCL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | TCL |
|---|---|---|
| Ducted, up to 1.5 tons | 21 · index 30% | 10 · index 62% |
| Ducted, 2 tons | 21 · index 31% | 11 · index 49% |
| Ducted, 2.5–3 tons | 46 · index 37% | 19 · index 59% |
| Ducted, 3.5–4.5 tons | 58 · index 41% | 22 · index 51% |
| Ducted, 5 tons and up | 21 · index 31% | None |
| Non-ducted, up to 1.5 tons | 20 · index 55% | 86 · index 47% |
| Non-ducted, 2 tons | 5 · index 50% | 18 · index 41% |
| Non-ducted, 2.5–3 tons | 4 · index 47% | 29 · index 47% |
| Non-ducted, 3.5–4.5 tons | 2 · index 47% | 12 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | TCLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.0(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ducted air handler FPHFA18A3D5 of 21 models qualify · AHRI 217505657 | 67.5(50 is the typical model of its size class)H18TDHXPCwith ducted air handler H18FAHUDE10 of 10 models qualify · AHRI 218332482 |
| Ducted, 2 tons | 70.3(50 is the typical model of its size class) (higher)RD18AY24AJVCwith indoor coil RCFY2417STANM and furnace FR801V0504A17UHU4 of 21 models qualify · AHRI 217176021 | 70.0(50 is the typical model of its size class)H24TDHXPCwith ducted air handler H24FAHUDE11 of 12 models qualify · AHRI 218332483 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 216891246 | 67.2(50 is the typical model of its size class)H30TDHXPCwith ducted air handler H30FAHUDE16 of 18 models qualify · AHRI 218332484 |
| Ducted, 3.5–4.5 tons | 83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D8 of 57 models qualify · AHRI 217508872 | 69.4(50 is the typical model of its size class)H48SDH20XQCwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H2621 of 22 models qualify · AHRI 218453819 |
| Ducted, 5 tons and up | 77.3(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR802V1255A24UHN1 of 22 models qualify · AHRI 218328124 | No models in this size class |
| Non-ducted, up to 1.5 tons | 82.4(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 | 70.9(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2566 of 86 models qualify · AHRI 218028413 |
| Non-ducted, 2 tons | 76.3(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 | 61.6(50 is the typical model of its size class)H24SBH23XQCwith ductless indoor unit H24SBH23XQE11 of 19 models qualify · AHRI 218451106 |
| Non-ducted, 2.5–3 tons | 58.2(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 | 68.0(50 is the typical model of its size class) (higher)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2519 of 28 models qualify · AHRI 218028414 |
| Non-ducted, 3.5–4.5 tons | 49.7(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 | 48.1(50 is the typical model of its size class)TMH48HEI2NAS0U25Also listed as H48FMHD6XPC11 of 12 models qualify · AHRI 218028416 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | TCLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.4(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D20 of 20 models have all five ratings · AHRI 217505657 | 72.9(50 is the typical model of its size class) (higher)TMH18HEI2NAS0U25*Also listed as H18FMHD3XPC10 of 10 models have all five ratings · AHRI 218625046 |
| Ducted, 2 tons | 75.1(50 is the typical model of its size class) (higher)FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M421 of 21 models have all five ratings · AHRI 216551633 | 70.0(50 is the typical model of its size class)THH24HDI2NAJ0H26with ducted air handler THH24IDI2NAJ0H2613 of 13 models have all five ratings · AHRI 218467218 |
| Ducted, 2.5–3 tons | 84.1(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler RH2VY3621MTACN30 of 46 models have all five ratings · AHRI 216613170 | 80.5(50 is the typical model of its size class)TMH27HEI2NAS0U25*17 of 17 models have all five ratings · AHRI 218625047 |
| Ducted, 3.5–4.5 tons | 84.1(50 is the typical model of its size class) (higher)FRP19AY48AJVCwith indoor coil RCFY4821SEAAM and furnace FR802V0754A17UH32 of 54 models have all five ratings · AHRI 216551827 | 67.5(50 is the typical model of its size class)TMH42HEI2NAM0U24Also listed as H42FMH20XPC22 of 22 models have all five ratings · AHRI 215351200 |
| Ducted, 5 tons and up | 70.3(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN14 of 26 models have all five ratings · AHRI 218328406 | No models in this size class |
| Non-ducted, up to 1.5 tons | 83.9(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 | 82.6(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2580 of 87 models have all five ratings · AHRI 218028413 |
| Non-ducted, 2 tons | 61.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 | 64.8(50 is the typical model of its size class) (higher)H24SBH23XQCwith ductless indoor unit H24SBH23XQE16 of 17 models have all five ratings · AHRI 218451106 |
| Non-ducted, 2.5–3 tons | 64.2(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 | 83.1(50 is the typical model of its size class) (higher)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2528 of 29 models have all five ratings · AHRI 218028414 |
| Non-ducted, 3.5–4.5 tons | 49.6(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 | 70.2(50 is the typical model of its size class) (higher)TMH48HEI2NAS0U25Also listed as H48FMHD6XPC12 of 12 models have all five ratings · AHRI 218028416 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | TCL |
|---|---|---|
| COP at 5°F | beats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tons | beats 88% · 2.25TSH24HDI2NAL0B25Also listed as H24SVH20XQCNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons | beats 99% · 125%H24TDHXPCDucted, 2 tons |
| HSPF2 | beats 86% · 10.0FRP19AY60AJVCDucted, 3.5–4.5 tons | beats 96% · 10.5TMH27HEI2NAS0U25*Ducted, 2.5–3 tons |
| SEER2 | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tons | beats 99% · 26.5TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5–3 tons |
| EER2 | beats 96% · 13.0RD18AY36AJVCDucted, 2.5–3 tons | beats 97% · 14.0TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons | beats 99% · 30,000 Btu/hH24TDHXPCDucted, 2 tons |