Skip to content

AUX vs Friedrich heat pumps

Measured against models of the same size and duct type, AUX scores higher on 6 of the 6 ratings. AUX has 189 outdoor models, Friedrich has 188 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AUX and Friedrich on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AUX scores higher on 6 of the 6 ratings.
  • AUX
  • Friedrich
  • Other ranked manufacturers
AUXFriedrich

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAUXFriedrich
Efficiency index49% (higher)median — · 21st ranked39% (higher)median — · 28th ranked
COP at 5°F60% (higher)median 2.00 · 7th ranked46% (higher)median 1.97 · 24th ranked
Capacity retention at 5°F51% (higher)median 75% · 15th ranked35% (higher)median 51% · 28th ranked
HSPF240% (higher)median 9.0 · 25th ranked31% (higher)median 7.5 · 28th ranked
SEER248% (higher)median 20.0 · 18th ranked34% (higher)median 15.2 · 28th ranked
EER239% (higher)median 11.0 · 27th ranked38% (higher)median 10.6 · 28th ranked
Heating capacity at 5°F49% (higher)median 9,600 Btu/h · 17th ranked34% (higher)median 17,000 Btu/h · 28th ranked
Outdoor models189188
AHRI certifications2236,795

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAUXFriedrich
CEE 2025 Tier 1 (Split ASHP)68.3%129 models27.1%51 models
CEE 2026 Tier 1 (Split ASHP)66.1%125 models23.9%45 models
CEE Advanced Tier (Split ASHP)1.1%2 models0.5%1 models
Xcel Energy Colorado cold-climate ASHP (2025)65.6%124 models21.3%40 models
DOE Cold Climate Heat Pump Challenge1.1%2 models0.5%1 models
ENERGY STAR Cold Climate34.9%66 models22.3%42 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • AUX
  • Friedrich
  • All models of the group
Ducted, up to 1.5 tons1.901,902 modelsDucted, 2 tons2.001,132 modelsDucted, 2.5–3 tons2.002,029 modelsDucted, 3.5–4.5 tons2.002,290 modelsDucted, 5 tons and up2.00341 modelsNon-ducted, up to 1.5 tons1.943,990 modelsNon-ducted, 2 tons2.00987 modelsNon-ducted, 2.5–3 tons2.001,210 modelsNon-ducted, 3.5–4.5 tons2.00591 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAUXFriedrich
Ducted, up to 1.5 tons6 · index 60%21 · index 31%
Ducted, 2 tons4 · index 59%21 · index 31%
Ducted, 2.5–3 tons9 · index 63%46 · index 36%
Ducted, 3.5–4.5 tons5 · index 61%57 · index 40%
Ducted, 5 tons and upNone22 · index 36%
Non-ducted, up to 1.5 tons120 · index 46%20 · index 57%
Non-ducted, 2 tons33 · index 52%5 · index 51%
Non-ducted, 2.5–3 tons22 · index 46%4 · index 48%
Non-ducted, 3.5–4.5 tons2 · index 73%2 · index 47%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAUXCold-climate score, best modelFriedrichCold-climate score, best model
Ducted, up to 1.5 tons75.4(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models qualify · AHRI 21603243773.7(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 217505657
Ducted, 2 tons62.9(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 21603243867.4(50 is the typical model of its size class) (higher)FRP17AY24AJVCwith indoor coil RCFY2417STANM and furnace FR962V0603A17M4S4 of 20 models qualify · AHRI 218328414
Ducted, 2.5–3 tons73.8(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 21603240078.5(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 216891246
Ducted, 3.5–4.5 tons77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 21603244083.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D9 of 57 models qualify · AHRI 217508872
Ducted, 5 tons and upNo models in this size class78.0(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110
Non-ducted, up to 1.5 tons83.5(50 is the typical model of its size class) (higher)AM2-H18/2DR3BAlso listed as ASUM18HPMULO80 of 120 models qualify · AHRI 21409794083.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408
Non-ducted, 2 tons84.6(50 is the typical model of its size class) (higher)AM3-H24/2DR3BAlso listed as ASUM24HPMULO16 of 33 models qualify · AHRI 21409794376.6(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155
Non-ducted, 2.5–3 tons73.4(50 is the typical model of its size class) (higher)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 21409794158.8(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608
Non-ducted, 3.5–4.5 tons60.1(50 is the typical model of its size class) (higher)ASUM42HPMULO2 of 2 models qualify · AHRI 21605094249.9(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAUXAll-around score, best modelFriedrichAll-around score, best model
Ducted, up to 1.5 tons79.8(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 21603243768.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657
Ducted, 2 tons78.2(50 is the typical model of its size class) (higher)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 21603243875.4(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA20 of 20 models have all five ratings · AHRI 215739593
Ducted, 2.5–3 tons81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 21603243985.1(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA33 of 46 models have all five ratings · AHRI 215584440
Ducted, 3.5–4.5 tons87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 21603244084.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA35 of 54 models have all five ratings · AHRI 215584441
Ducted, 5 tons and upNo models in this size class70.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406
Non-ducted, up to 1.5 tons84.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 21521892885.0(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408
Non-ducted, 2 tons87.0(50 is the typical model of its size class) (higher)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 21711527463.2(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820
Non-ducted, 2.5–3 tons78.5(50 is the typical model of its size class) (higher)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 21409794164.8(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839
Non-ducted, 3.5–4.5 tons74.4(50 is the typical model of its size class) (higher)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 21605094249.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAUXFriedrich
COP at 5°Fbeats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tonsbeats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 108%AM3-H24/2DR3BAlso listed as ASUM24HPMULONon-ducted, 2 tonsbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons
HSPF2beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5–3 tonsbeats 90% · 9.5FRP17AY60AJVCDucted, 5 tons and up
SEER2beats 100% · 22.0ASUM42HPMULODucted, 3.5–4.5 tonsbeats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tons
EER2beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tonsbeats 97% · 13.0RD18AY36AJVCDucted, 2.5–3 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hAM2-H18/2DR3BAlso listed as ASUM18HPMULONon-ducted, up to 1.5 tonsbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
AUX vs Friedrich: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,130 models (45.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • AUX (median, middle 50%)
  • Friedrich (median, middle 50%)
Heating capacity, % of its 47°F maximum70%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,130100%100%100%100%100%
All rated models, 17°F6,13064%69%74%83%91%
All rated models, 5°F6,13057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,1302.83.013.243.483.66
All rated models, 17°F6,13022.142.32.422.61
All rated models, 5°F6,1301.81.8722.12.24
AUX: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F65100%100%100%100%100%
AUX, 17°F6567%70%73%79%85%
AUX, 5°F6562%65%70%73%83%
AUX: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F652.933.183.33.523.72
AUX, 17°F652.12.172.282.342.45
AUX, 5°F651.89222.12.18
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1

Source: NEEP ccASHP list · as of

More comparisons