Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AUX vs Friedrich heat pumps
Measured against models of the same size and duct type, AUX scores higher on 6 of the 6 ratings. AUX has 189 outdoor models, Friedrich has 188 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AUX
- Friedrich
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AUX | Friedrich |
|---|---|---|
| Efficiency index | 49% (higher)median — · 21st ranked | 39% (higher)median — · 28th ranked |
| COP at 5°F | 60% (higher)median 2.00 · 7th ranked | 46% (higher)median 1.97 · 24th ranked |
| Capacity retention at 5°F | 51% (higher)median 75% · 15th ranked | 35% (higher)median 51% · 28th ranked |
| HSPF2 | 40% (higher)median 9.0 · 25th ranked | 31% (higher)median 7.5 · 28th ranked |
| SEER2 | 48% (higher)median 20.0 · 18th ranked | 34% (higher)median 15.2 · 28th ranked |
| EER2 | 39% (higher)median 11.0 · 27th ranked | 38% (higher)median 10.6 · 28th ranked |
| Heating capacity at 5°F | 49% (higher)median 9,600 Btu/h · 17th ranked | 34% (higher)median 17,000 Btu/h · 28th ranked |
| Outdoor models | 189 | 188 |
| AHRI certifications | 223 | 6,795 |
Share of models meeting each standard
| Standard | AUX | Friedrich |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.3%129 models | 27.1%51 models |
| CEE 2026 Tier 1 (Split ASHP) | 66.1%125 models | 23.9%45 models |
| CEE Advanced Tier (Split ASHP) | 1.1%2 models | 0.5%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 65.6%124 models | 21.3%40 models |
| DOE Cold Climate Heat Pump Challenge | 1.1%2 models | 0.5%1 models |
| ENERGY STAR Cold Climate | 34.9%66 models | 22.3%42 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AUX
- Friedrich
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AUX | Friedrich |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 60% | 21 · index 31% |
| Ducted, 2 tons | 4 · index 59% | 21 · index 31% |
| Ducted, 2.5–3 tons | 9 · index 63% | 46 · index 36% |
| Ducted, 3.5–4.5 tons | 5 · index 61% | 57 · index 40% |
| Ducted, 5 tons and up | None | 22 · index 36% |
| Non-ducted, up to 1.5 tons | 120 · index 46% | 20 · index 57% |
| Non-ducted, 2 tons | 33 · index 52% | 5 · index 51% |
| Non-ducted, 2.5–3 tons | 22 · index 46% | 4 · index 48% |
| Non-ducted, 3.5–4.5 tons | 2 · index 73% | 2 · index 47% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AUXCold-climate score, best model | FriedrichCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.4(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models qualify · AHRI 216032437 | 73.7(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 217505657 |
| Ducted, 2 tons | 62.9(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 216032438 | 67.4(50 is the typical model of its size class) (higher)FRP17AY24AJVCwith indoor coil RCFY2417STANM and furnace FR962V0603A17M4S4 of 20 models qualify · AHRI 218328414 |
| Ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 216032400 | 78.5(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 216891246 |
| Ducted, 3.5–4.5 tons | 77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 216032440 | 83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D9 of 57 models qualify · AHRI 217508872 |
| Ducted, 5 tons and up | No models in this size class | 78.0(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110 |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class) (higher)AM2-H18/2DR3BAlso listed as ASUM18HPMULO80 of 120 models qualify · AHRI 214097940 | 83.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 |
| Non-ducted, 2 tons | 84.6(50 is the typical model of its size class) (higher)AM3-H24/2DR3BAlso listed as ASUM24HPMULO16 of 33 models qualify · AHRI 214097943 | 76.6(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 |
| Non-ducted, 2.5–3 tons | 73.4(50 is the typical model of its size class) (higher)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 214097941 | 58.8(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class) (higher)ASUM42HPMULO2 of 2 models qualify · AHRI 216050942 | 49.9(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 |
All-around best
| Size and duct type | AUXAll-around score, best model | FriedrichAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.8(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 216032437 | 68.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657 |
| Ducted, 2 tons | 78.2(50 is the typical model of its size class) (higher)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 216032438 | 75.4(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA20 of 20 models have all five ratings · AHRI 215739593 |
| Ducted, 2.5–3 tons | 81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 216032439 | 85.1(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA33 of 46 models have all five ratings · AHRI 215584440 |
| Ducted, 3.5–4.5 tons | 87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 216032440 | 84.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA35 of 54 models have all five ratings · AHRI 215584441 |
| Ducted, 5 tons and up | No models in this size class | 70.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406 |
| Non-ducted, up to 1.5 tons | 84.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 215218928 | 85.0(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 |
| Non-ducted, 2 tons | 87.0(50 is the typical model of its size class) (higher)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 217115274 | 63.2(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 |
| Non-ducted, 2.5–3 tons | 78.5(50 is the typical model of its size class) (higher)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 214097941 | 64.8(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 |
| Non-ducted, 3.5–4.5 tons | 74.4(50 is the typical model of its size class) (higher)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 216050942 | 49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AUX | Friedrich |
|---|---|---|
| COP at 5°F | beats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tons | beats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 99% · 108%AM3-H24/2DR3BAlso listed as ASUM24HPMULONon-ducted, 2 tons | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons |
| HSPF2 | beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5–3 tons | beats 90% · 9.5FRP17AY60AJVCDucted, 5 tons and up |
| SEER2 | beats 100% · 22.0ASUM42HPMULODucted, 3.5–4.5 tons | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tons |
| EER2 | beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tons | beats 97% · 13.0RD18AY36AJVCDucted, 2.5–3 tons |
| Heating capacity at 5°F | beats 99% · 21,800 Btu/hAM2-H18/2DR3BAlso listed as ASUM18HPMULONon-ducted, up to 1.5 tons | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- AUX (median, middle 50%)
- Friedrich (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,130 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,130 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 2.8 | 3.01 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,130 | 2 | 2.14 | 2.3 | 2.42 | 2.61 |
| All rated models, 5°F | 6,130 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 100% | 100% | 100% | 100% | 100% |
| AUX, 17°F | 65 | 67% | 70% | 73% | 79% | 85% |
| AUX, 5°F | 65 | 62% | 65% | 70% | 73% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 2.93 | 3.18 | 3.3 | 3.52 | 3.72 |
| AUX, 17°F | 65 | 2.1 | 2.17 | 2.28 | 2.34 | 2.45 |
| AUX, 5°F | 65 | 1.89 | 2 | 2 | 2.1 | 2.18 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 100% | 100% | 100% | 100% | 100% |
| Friedrich, 17°F | 44 | 60% | 65% | 68% | 84% | 92% |
| Friedrich, 5°F | 44 | 57% | 62% | 71% | 74% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 2.8 | 2.9 | 3.08 | 3.21 | 3.46 |
| Friedrich, 17°F | 44 | 2.07 | 2.2 | 2.4 | 2.5 | 2.51 |
| Friedrich, 5°F | 44 | 1.89 | 1.9 | 2 | 2.09 | 2.1 |
Source: NEEP ccASHP list · as of