Skip to content

AUX vs BlueRidge heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. AUX has 189 outdoor models, BlueRidge has 194 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AUX and BlueRidge on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings.
  • AUX
  • BlueRidge
  • Other ranked manufacturers
AUXBlueRidge

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAUXBlueRidge
Efficiency index49%median — · 21st ranked57%median — · 9th ranked
COP at 5°F60% (higher)median 2.00 · 7th ranked57% (higher)median 2.00 · 13th ranked
Capacity retention at 5°F51%median 75% · 15th ranked55%median 74% · 12th ranked
HSPF240%median 9.0 · 25th ranked60%median 9.5 · 9th ranked
SEER248%median 20.0 · 18th ranked58%median 19.0 · 9th ranked
EER239%median 11.0 · 27th ranked54%median 11.9 · 15th ranked
Heating capacity at 5°F49%median 9,600 Btu/h · 17th ranked57%median 19,000 Btu/h · 11th ranked
Outdoor models189194
AHRI certifications2231,700

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAUXBlueRidge
CEE 2025 Tier 1 (Split ASHP)68.3%129 models75.3%146 models
CEE 2026 Tier 1 (Split ASHP)66.1%125 models73.2%142 models
CEE Advanced Tier (Split ASHP)1.1%2 models3.6%7 models
Xcel Energy Colorado cold-climate ASHP (2025)65.6%124 models68%132 models
DOE Cold Climate Heat Pump Challenge1.1%2 models3.6%7 models
ENERGY STAR Cold Climate34.9%66 models64.4%125 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • AUX
  • BlueRidge
  • All models of the group
Ducted, up to 1.5 tons1.901,902 modelsDucted, 2 tons2.001,132 modelsDucted, 2.5–3 tons2.002,029 modelsDucted, 3.5–4.5 tons2.002,290 modelsDucted, 5 tons and up2.00341 modelsNon-ducted, up to 1.5 tons1.943,990 modelsNon-ducted, 2 tons2.00987 modelsNon-ducted, 2.5–3 tons2.001,210 modelsNon-ducted, 3.5–4.5 tons2.00591 modelsNon-ducted, 5 tons and up2.0588 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAUXBlueRidge
Ducted, up to 1.5 tons6 · index 60%29 · index 70%
Ducted, 2 tons4 · index 59%21 · index 59%
Ducted, 2.5–3 tons9 · index 63%38 · index 56%
Ducted, 3.5–4.5 tons5 · index 61%36 · index 60%
Ducted, 5 tons and upNone5 · index 64%
Non-ducted, up to 1.5 tons120 · index 46%74 · index 55%
Non-ducted, 2 tons33 · index 52%17 · index 51%
Non-ducted, 2.5–3 tons22 · index 46%26 · index 51%
Non-ducted, 3.5–4.5 tons2 · index 73%20 · index 47%
Non-ducted, 5 tons and upNone2 · index 59%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAUXCold-climate score, best modelBlueRidgeCold-climate score, best model
Ducted, up to 1.5 tons75.4(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models qualify · AHRI 21603243793.7(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 215853938
Ducted, 2 tons62.9(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 21603243885.9(50 is the typical model of its size class) (higher)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC017 of 21 models qualify · AHRI 215853945
Ducted, 2.5–3 tons73.8(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 21603240083.7(50 is the typical model of its size class) (higher)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC023 of 38 models qualify · AHRI 215853961
Ducted, 3.5–4.5 tons77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 21603244083.9(50 is the typical model of its size class) (higher)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 217992607
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 5 models qualify)
Non-ducted, up to 1.5 tons83.5(50 is the typical model of its size class)AM2-H18/2DR3BAlso listed as ASUM18HPMULO80 of 120 models qualify · AHRI 21409794097.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 215853901
Non-ducted, 2 tons84.6(50 is the typical model of its size class)AM3-H24/2DR3BAlso listed as ASUM24HPMULO16 of 33 models qualify · AHRI 21409794390.0(50 is the typical model of its size class) (higher)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 215853933
Non-ducted, 2.5–3 tons73.4(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 21409794189.3(50 is the typical model of its size class) (higher)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 215853964
Non-ducted, 3.5–4.5 tons60.1(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 21605094273.6(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 215853990
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAUXAll-around score, best modelBlueRidgeAll-around score, best model
Ducted, up to 1.5 tons79.8(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 21603243795.1(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 215853938
Ducted, 2 tons78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 21603243878.8(50 is the typical model of its size class) (higher)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC019 of 19 models have all five ratings · AHRI 215853924
Ducted, 2.5–3 tons81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 21603243984.0(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC039 of 39 models have all five ratings · AHRI 215853986
Ducted, 3.5–4.5 tons87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 21603244085.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 215853977
Ducted, 5 tons and upNo models in this size class67.3(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371909
Non-ducted, up to 1.5 tons84.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 21521892896.5(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 215853901
Non-ducted, 2 tons87.0(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 21711527487.6(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 215853900
Non-ducted, 2.5–3 tons78.5(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 21409794178.6(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 215853985
Non-ducted, 3.5–4.5 tons74.4(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 21605094275.5(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 215853988
Non-ducted, 5 tons and upNo models in this size class58.7(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAUXBlueRidge
COP at 5°Fbeats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tonsbeats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 108%AM3-H24/2DR3BAlso listed as ASUM24HPMULONon-ducted, 2 tonsbeats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons
HSPF2beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5–3 tonsbeats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons
SEER2beats 100% · 22.0ASUM42HPMULODucted, 3.5–4.5 tonsbeats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons
EER2beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tonsbeats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hAM2-H18/2DR3BAlso listed as ASUM18HPMULONon-ducted, up to 1.5 tonsbeats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
AUX vs BlueRidge: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,130 models (45.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • AUX (median, middle 50%)
  • BlueRidge (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,130100%100%100%100%100%
All rated models, 17°F6,13064%69%74%83%91%
All rated models, 5°F6,13057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,1302.83.013.243.483.66
All rated models, 17°F6,13022.142.32.422.61
All rated models, 5°F6,1301.81.8722.12.24
AUX: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F65100%100%100%100%100%
AUX, 17°F6567%70%73%79%85%
AUX, 5°F6562%65%70%73%83%
AUX: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F652.933.183.33.523.72
AUX, 17°F652.12.172.282.342.45
AUX, 5°F651.89222.12.18
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F175100%100%100%100%100%
BlueRidge, 17°F17564%68%74%82%88%
BlueRidge, 5°F17557%60%66%78%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F1752.883.073.233.473.59
BlueRidge, 17°F1752.032.192.332.412.61
BlueRidge, 5°F1751.831.9622.142.31

Source: NEEP ccASHP list · as of