Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AUX vs BlueRidge heat pumps
Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. AUX has 189 outdoor models, BlueRidge has 194 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AUX
- BlueRidge
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AUX | BlueRidge |
|---|---|---|
| Efficiency index | 49%median — · 21st ranked | 57%median — · 9th ranked |
| COP at 5°F | 60% (higher)median 2.00 · 7th ranked | 57% (higher)median 2.00 · 13th ranked |
| Capacity retention at 5°F | 51%median 75% · 15th ranked | 55%median 74% · 12th ranked |
| HSPF2 | 40%median 9.0 · 25th ranked | 60%median 9.5 · 9th ranked |
| SEER2 | 48%median 20.0 · 18th ranked | 58%median 19.0 · 9th ranked |
| EER2 | 39%median 11.0 · 27th ranked | 54%median 11.9 · 15th ranked |
| Heating capacity at 5°F | 49%median 9,600 Btu/h · 17th ranked | 57%median 19,000 Btu/h · 11th ranked |
| Outdoor models | 189 | 194 |
| AHRI certifications | 223 | 1,700 |
Share of models meeting each standard
| Standard | AUX | BlueRidge |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.3%129 models | 75.3%146 models |
| CEE 2026 Tier 1 (Split ASHP) | 66.1%125 models | 73.2%142 models |
| CEE Advanced Tier (Split ASHP) | 1.1%2 models | 3.6%7 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 65.6%124 models | 68%132 models |
| DOE Cold Climate Heat Pump Challenge | 1.1%2 models | 3.6%7 models |
| ENERGY STAR Cold Climate | 34.9%66 models | 64.4%125 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AUX
- BlueRidge
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AUX | BlueRidge |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 60% | 29 · index 70% |
| Ducted, 2 tons | 4 · index 59% | 21 · index 59% |
| Ducted, 2.5–3 tons | 9 · index 63% | 38 · index 56% |
| Ducted, 3.5–4.5 tons | 5 · index 61% | 36 · index 60% |
| Ducted, 5 tons and up | None | 5 · index 64% |
| Non-ducted, up to 1.5 tons | 120 · index 46% | 74 · index 55% |
| Non-ducted, 2 tons | 33 · index 52% | 17 · index 51% |
| Non-ducted, 2.5–3 tons | 22 · index 46% | 26 · index 51% |
| Non-ducted, 3.5–4.5 tons | 2 · index 73% | 20 · index 47% |
| Non-ducted, 5 tons and up | None | 2 · index 59% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AUXCold-climate score, best model | BlueRidgeCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.4(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models qualify · AHRI 216032437 | 93.7(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 215853938 |
| Ducted, 2 tons | 62.9(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 216032438 | 85.9(50 is the typical model of its size class) (higher)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC017 of 21 models qualify · AHRI 215853945 |
| Ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 216032400 | 83.7(50 is the typical model of its size class) (higher)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC023 of 38 models qualify · AHRI 215853961 |
| Ducted, 3.5–4.5 tons | 77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 216032440 | 83.9(50 is the typical model of its size class) (higher)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 217992607 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 5 models qualify) |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class)AM2-H18/2DR3BAlso listed as ASUM18HPMULO80 of 120 models qualify · AHRI 214097940 | 97.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 215853901 |
| Non-ducted, 2 tons | 84.6(50 is the typical model of its size class)AM3-H24/2DR3BAlso listed as ASUM24HPMULO16 of 33 models qualify · AHRI 214097943 | 90.0(50 is the typical model of its size class) (higher)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 215853933 |
| Non-ducted, 2.5–3 tons | 73.4(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 214097941 | 89.3(50 is the typical model of its size class) (higher)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 215853964 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 216050942 | 73.6(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 215853990 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | AUXAll-around score, best model | BlueRidgeAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.8(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 216032437 | 95.1(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 215853938 |
| Ducted, 2 tons | 78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 216032438 | 78.8(50 is the typical model of its size class) (higher)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC019 of 19 models have all five ratings · AHRI 215853924 |
| Ducted, 2.5–3 tons | 81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 216032439 | 84.0(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC039 of 39 models have all five ratings · AHRI 215853986 |
| Ducted, 3.5–4.5 tons | 87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 216032440 | 85.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 215853977 |
| Ducted, 5 tons and up | No models in this size class | 67.3(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371909 |
| Non-ducted, up to 1.5 tons | 84.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 215218928 | 96.5(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 215853901 |
| Non-ducted, 2 tons | 87.0(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 217115274 | 87.6(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 215853900 |
| Non-ducted, 2.5–3 tons | 78.5(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 214097941 | 78.6(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 215853985 |
| Non-ducted, 3.5–4.5 tons | 74.4(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 216050942 | 75.5(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 215853988 |
| Non-ducted, 5 tons and up | No models in this size class | 58.7(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AUX | BlueRidge |
|---|---|---|
| COP at 5°F | beats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tons | beats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 99% · 108%AM3-H24/2DR3BAlso listed as ASUM24HPMULONon-ducted, 2 tons | beats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons |
| HSPF2 | beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5–3 tons | beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 22.0ASUM42HPMULODucted, 3.5–4.5 tons | beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons |
| EER2 | beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tons | beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 21,800 Btu/hAM2-H18/2DR3BAlso listed as ASUM18HPMULONon-ducted, up to 1.5 tons | beats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- AUX (median, middle 50%)
- BlueRidge (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,130 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,130 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 2.8 | 3.01 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,130 | 2 | 2.14 | 2.3 | 2.42 | 2.61 |
| All rated models, 5°F | 6,130 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 100% | 100% | 100% | 100% | 100% |
| AUX, 17°F | 65 | 67% | 70% | 73% | 79% | 85% |
| AUX, 5°F | 65 | 62% | 65% | 70% | 73% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 2.93 | 3.18 | 3.3 | 3.52 | 3.72 |
| AUX, 17°F | 65 | 2.1 | 2.17 | 2.28 | 2.34 | 2.45 |
| AUX, 5°F | 65 | 1.89 | 2 | 2 | 2.1 | 2.18 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 100% | 100% | 100% | 100% | 100% |
| BlueRidge, 17°F | 175 | 64% | 68% | 74% | 82% | 88% |
| BlueRidge, 5°F | 175 | 57% | 60% | 66% | 78% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 2.88 | 3.07 | 3.23 | 3.47 | 3.59 |
| BlueRidge, 17°F | 175 | 2.03 | 2.19 | 2.33 | 2.41 | 2.61 |
| BlueRidge, 5°F | 175 | 1.83 | 1.96 | 2 | 2.14 | 2.31 |
Source: NEEP ccASHP list · as of