Skip to content

BlueRidge vs Friedrich heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 6 of the 6 ratings. BlueRidge has 194 outdoor models, Friedrich has 192 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Friedrich on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 6 of the 6 ratings.
  • BlueRidge
  • Friedrich
  • Other ranked manufacturers
BlueRidgeFriedrich

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeFriedrich
Efficiency index57% (higher)median — · 10th ranked40% (higher)median — · 28th ranked
COP at 5°F57% (higher)median 2.00 · 13th ranked46% (higher)median 1.99 · 22nd ranked
Capacity retention at 5°F55% (higher)median 74% · 12th ranked36% (higher)median 51% · 27th ranked
HSPF260% (higher)median 9.5 · 9th ranked32% (higher)median 7.5 · 28th ranked
SEER258% (higher)median 19.0 · 9th ranked35% (higher)median 15.2 · 28th ranked
EER254% (higher)median 11.9 · 15th ranked38% (higher)median 10.6 · 29th ranked
Heating capacity at 5°F57% (higher)median 19,000 Btu/h · 11th ranked34% (higher)median 17,400 Btu/h · 28th ranked
Outdoor models194192
AHRI certifications1,7006,800

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeFriedrich
CEE 2025 Tier 1 (Split ASHP)75.3%146 models28.1%54 models
CEE 2026 Tier 1 (Split ASHP)73.2%142 models25%48 models
CEE Advanced Tier (Split ASHP)3.6%7 models0.5%1 models
Xcel Energy Colorado cold-climate ASHP (2025)68%132 models22.4%43 models
DOE Cold Climate Heat Pump Challenge3.6%7 models0.5%1 models
ENERGY STAR Cold Climate64.4%125 models21.9%42 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • BlueRidge
  • Friedrich
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeFriedrich
Ducted, up to 1.5 tons29 · index 70%20 · index 31%
Ducted, 2 tons21 · index 59%23 · index 32%
Ducted, 2.5 to 3 tons38 · index 56%47 · index 36%
Ducted, 3.5 to 4.5 tons36 · index 60%59 · index 41%
Ducted, 5 tons and up5 · index 64%22 · index 36%
Non-ducted, up to 1.5 tons74 · index 55%20 · index 57%
Non-ducted, 2 tons17 · index 51%5 · index 52%
Non-ducted, 2.5 to 3 tons26 · index 51%4 · index 48%
Non-ducted, 3.5 to 4.5 tons20 · index 47%2 · index 47%
Non-ducted, 5 tons and up2 · index 59%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelFriedrichCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 21585393873.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 217505657
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC018 of 22 models qualify · AHRI 21585394570.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 219125948
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 21585396178.4(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 216891246
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 21799260783.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 217508872
Ducted, 5 tons and upNone on this board (0 of 5 models qualify)78.1(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 21585390183.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 21585393376.9(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 21585396459.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 21585399049.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelFriedrichAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 21585393868.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657
Ducted, 2 tons78.9(50 is the typical model of its size class) (higher)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 21585392475.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 215739593
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC037 of 37 models have all five ratings · AHRI 21585398684.9(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 215584440
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 21585397784.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 215584441
Ducted, 5 tons and up67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637190970.6(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 21585390185.1(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 21585390063.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 21585398564.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 21585398849.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeFriedrich
COP at 5°Fbeats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tonsbeats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons
HSPF2beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and up
SEER2beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tons
EER2beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tonsbeats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tonsbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs Friedrich: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • Friedrich (median, middle 50%)
Heating capacity, % of its 47°F maximum66%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F175100%100%100%100%100%
BlueRidge, 17°F17564%68%74%82%88%
BlueRidge, 5°F17557%60%66%78%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F1752.883.073.233.473.59
BlueRidge, 17°F1752.032.192.332.412.61
BlueRidge, 5°F1751.831.9622.142.31
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter