Skip to content

Friedrich heat pump efficiency: 192 outdoor models compared

Friedrich has 192 heat pump outdoor models certified with this refrigerant group, in 6,800 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Friedrich makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
192
AHRI certifications
6,800
Efficiency index
40%
Typical model vs same-size, same-type peers (160 models)
Meet CEE 2025
28.1%
54 models

How Friedrich compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Friedrich against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Friedrich’s own modelsFriedrich is strongest on COP at 5°F (its typical model beats 46% of comparable models) and weakest on HSPF2 (32%).
  • Friedrich
  • Middle half of its models
  • Other ranked manufacturers
Friedrich

Source: AHRI Directory, NEEP · as of

Average peer percentile of Friedrich’s models
RatingBeats comparable modelsRankRaw median
Efficiency index160 models scored40%28th of 29—
COP at 5°F160 models scored46%22nd of 291.99
Capacity retention at 5°F160 models scored36%27th of 2951%
HSPF2202 models scored32%28th of 297.5
SEER2202 models scored35%28th of 2915.2
EER2202 models scored38%29th of 2910.6
Heating capacity at 5°F158 models scored34%28th of 2917,400 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Friedrich’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Friedrich (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons2031%41%20%34%
Ducted, 2 tons2332%47%27%31%
Ducted, 2.5 to 3 tons4736%50%28%29%
Ducted, 3.5 to 4.5 tons5941%53%31%34%
Ducted, 5 tons and up2236%19%33%31%
Non-ducted, up to 1.5 tons2057%55%56%51%
Non-ducted, 2 tons552%43%41%50%
Non-ducted, 2.5 to 3 tons448%26%41%47%
Non-ducted, 3.5 to 4.5 tons247%22%14%50%

Every Friedrich model in the market

Friedrich’s 202 models with a known size and duct type, over the shape of the whole catalog.
Friedrich models by size and ratingColoured: Friedrich · grey shapes: all 15,936 models · lines: catalog medians by size
  • Friedrich models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 202 friedrich models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Friedrich in the cold

From NEEP’s cold-climate listings: 44 Friedrich models against all 6,343 listed models.
Friedrich capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical Friedrich model keeps 71% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • Friedrich (median, middle 50%)
Heating capacity, % of its 47°F maximum71%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1

Source: NEEP ccASHP list · as of

Top Friedrich models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Friedrich cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1FPHFR48A3DFriedrich · Floating Air Pro Xwith ducted air handler FPHFA48A3D4 tons48,000 Btu/h · Ducted100%2.1010.048,00019.0CEE 25CEE 26CEE AdvXcelDOEES CC17217508872Ducted, 3.5 to 4.5 tons83.9
2FPHSR09A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D1 ton9,000 Btu/h · Non-ducted100%2.0911.09,00025.0CEE 25CEE 26XcelES CC2214232408Non-ducted, up to 1.5 tons83.4
3RD18AY48AJVCFRIEDRICH · K-SERIESwith indoor coil RCFY4821STANM and furnace FR98MV1005A21UP3.5 tons40,500 Btu/h · Ducted94%2.1010.038,00017.0CEE 25CEE 26XcelES CC252216820137Ducted, 3.5 to 4.5 tons81.5
4FRP19AY48AJVCFRIEDRICH · K-SERIESwith ducted air handler FRHMVY4821SEACA4 tons45,500 Btu/h · Ducted92%2.1010.042,00019.0CEE 25CEE 26Xcel28215584441Ducted, 3.5 to 4.5 tons80.8
5RD18AY36AJVCFRIEDRICH · K-SERIESwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN2.5 tons32,200 Btu/h · Ducted87%2.1010.028,00018.0CEE 25CEE 26XcelES CC386216891246Ducted, 2.5 to 3 tons78.4

All-around best

Top 5 Friedrich models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1FPHSR09A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D1 ton9,000 Btu/h · Non-ducted100%2.0911.025.013.7CEE 25CEE 26XcelES CC2214232408Non-ducted, up to 1.5 tons85.183.486.783.4
2FRP19AY36AJVCFRIEDRICH · K-SERIESwith ducted air handler FRHMVY3621MEACA3 tons34,200 Btu/h · Ducted86%2.109.520.012.5CEE 25CEE 26XcelES CC37215584440Ducted, 2.5 to 3 tons84.975.694.275.6
3FRP19AY48AJVCFRIEDRICH · K-SERIESwith ducted air handler FRHMVY4821SEACA4 tons45,500 Btu/h · Ducted92%2.1010.019.012.0CEE 25CEE 26Xcel28215584441Ducted, 3.5 to 4.5 tons84.380.887.880.8
4RD18AY36AJVCFRIEDRICH · K-SERIESwith ducted air handler RH2VY3621MTACN2.5 tons32,800 Btu/h · Ducted85%2.1010.019.013.0CEE 25CEE 26XcelES CC386216613170Ducted, 2.5 to 3 tons84.077.191.078.4
5RD18AY48AJVCFRIEDRICH · K-SERIESwith ducted air handler FRH2VY4824STACN3.5 tons41,500 Btu/h · Ducted90%2.1010.019.012.0CEE 25CEE 26XcelES CC252217166007Ducted, 3.5 to 4.5 tons83.779.787.881.5

Best model on each rating

Friedrich’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FFSHSR18B3BAlso listed as FSHSR18B3D2.40Non-ducted, up to 1.5 tons97%214604197
Capacity retention at 5°FFPHFR09A3D133%Ducted, up to 1.5 tons100%216626150
HSPF2FRP17AY60AJVC9.5Ducted, 5 tons and up91%218159990
SEER2FRP19AY36AJVC21.0Ducted, 2.5 to 3 tons98%216051079
EER2RD18AY36AJVC13.0Ducted, 2.5 to 3 tons96%216613170
Heating capacity at 5°FRD18AY24AJVC18,600 Btu/hDucted, up to 1.5 tons96%217175996

All 192 Friedrich models in Explore

Friedrich size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Friedrich: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons73.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 21750565768.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657
Ducted, 2 tons70.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 21912594875.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 215739593
Ducted, 2.5 to 3 tons78.4(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 21689124684.9(50 is the typical model of its size class)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 215584440
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 21750887284.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 215584441
Ducted, 5 tons and up78.1(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 21832811070.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 21423240885.1(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408
Non-ducted, 2 tons76.9(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 21662615563.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820
Non-ducted, 2.5 to 3 tons59.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 21669960864.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839
Non-ducted, 3.5 to 4.5 tons49.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 21669960949.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609

All-around board, every manufacturer

Newest Friedrich certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Friedrich outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
RD17AY60AJVCFRIEDRICH · F-Serieswith ducted air handler FRH2VY6024STACN4.5 tons56,000 Btu/h · Ducted2.2082%9.517.0CEE 25CEE 26Xcel1219125954
RD17AY48AJVCFRIEDRICH · F-Serieswith ducted air handler FRH2VY4821STACN3.5 tons44,000 Btu/h · Ducted2.1083%9.516.2None1219125952
RD17AY36AJVCFRIEDRICH · F-Serieswith ducted air handler FRH2VY3617STACN3 tons33,000 Btu/h · Ducted2.0075%9.016.5CEE 25CEE 26Xcel1219125950
RD17AY24AJVCFRIEDRICH · F-Serieswith ducted air handler FRH2VY2417STACN2 tons22,600 Btu/h · Ducted2.2081%9.517.0CEE 25CEE 26Xcel1219125948
WFPU17Y363DFRIEDRICHwith ducted air handler A(E,F)W36J+TDR2.5 tons31,000 Btu/h · Ducted2.0063%8.116.0CEE 25CEE 2675218859857

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Friedrich

Manufacturers of a similar size, side by side.

Friedrich includes these brand names as listed in AHRI: FRIEDRICH. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter