Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
OLMO heat pump efficiency: 11 outdoor models compared
OLMO has 11 heat pump outdoor models certified with this refrigerant group, in 17 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes OLMO makes. OLMO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 11
- AHRI certifications
- 17
- Efficiency index
- 43%
- Typical model vs same-size, same-type peers (11 models)
- Meet CEE 2025
- 90.9%
- 10 models
How OLMO compares with comparable models
- OLMO
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index11 models scored | 43% | Not ranked | — |
| COP at 5°F11 models scored | 45% | Not ranked | 1.98 |
| Capacity retention at 5°F11 models scored | 40% | Not ranked | 74% |
| HSPF211 models scored | 33% | Not ranked | 9.0 |
| SEER211 models scored | 45% | Not ranked | 20.0 |
| EER211 models scored | 50% | Not ranked | 12.0 |
| Heating capacity at 5°F11 models scored | 41% | Not ranked | 18,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 90.9% | 10 |
| CEE 2026 Tier 1 (Split ASHP) | 81.8% | 9 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 54.5% | 6 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 36.4% | 4 |
Sizes and duct types offered
- OLMO (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 6 | 43% | 67% | 33% | 38% |
| Non-ducted, 2 tons | 1 | 34% | 38% | 24% | 31% |
| Non-ducted, 2.5–3 tons | 3 | 47% | 17% | 41% | 55% |
| Non-ducted, 3.5–4.5 tons | 1 | 44% | 7% | 14% | 73% |
Every OLMO model in the market
- OLMO models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top OLMO models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OS-RMS18-230VOOLMO · SIERRA | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 18,000 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 217739001 | Non-ducted, up to 1.5 tons | 69.5 |
| 2OS-SR18-230VOOLMO · SIERRAwith ductless indoor unit OS-18SRW-230VI | 1.5 tons18,000 Btu/h · Non-ducted | 76% | 2.49 | 9.8 | 13,700 | 21.0 | CEE 25CEE 26Xcel | 2 | 215887337 | Non-ducted, up to 1.5 tons | 69.0 |
| 3OS-RMS36-230VOOLMO · SIERRA | 3 tons36,000 Btu/h · Non-ducted | 100% | 1.90 | 10.0 | 36,000 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 217739004 | Non-ducted, 2.5–3 tons | 53.7 |
| 4OS-RMS27-230VOOLMO · SIERRA | 2.5 tons27,000 Btu/h · Non-ducted | 100% | 1.80 | 10.0 | 27,000 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217739002 | Non-ducted, 2.5–3 tons | 50.2 |
| 5OS-SR24-230VOOLMOwith ductless indoor unit OS-A24SRW-230VI | 2 tons24,000 Btu/h · Non-ducted | 76% | 1.98 | 9.0 | 18,200 | 19.5 | CEE 25CEE 26Xcel | 2 | 218752476 | Non-ducted, 2 tons | 38.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OS-RMS18-230VOOLMO · SIERRA | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 22.0 | 13.3 | CEE 25CEE 26XcelES CC | 1 | 217739001 | Non-ducted, up to 1.5 tons | 69.2 | 69.5 | 68.9 | 69.5 |
| 2OS-RMS27-230VOOLMO · SIERRA | 2.5 tons27,000 Btu/h · Non-ducted | 100% | 1.80 | 10.0 | 23.0 | 12.9 | CEE 25CEE 26XcelES CC | 1 | 217739002 | Non-ducted, 2.5–3 tons | 64.2 | 50.2 | 78.2 | 50.2 |
| 3OS-RMS36-230VOOLMO · SIERRA | 3 tons36,000 Btu/h · Non-ducted | 100% | 1.90 | 10.0 | 22.0 | 12.9 | CEE 25CEE 26XcelES CC | 1 | 217739004 | Non-ducted, 2.5–3 tons | 61.7 | 53.7 | 69.7 | 53.7 |
| 4OS-SR09-230VOOLMO · SIERRAwith ductless indoor unit OS-09SRW-230VI | 1 ton9,000 Btu/h · Non-ducted | 63% | 2.10 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26 | 2 | 215887335 | Non-ducted, up to 1.5 tons | 56.7 | 45.4 | 68.1 | Not a pick |
| 5OS-SR18-230VOOLMO · SIERRAwith ductless indoor unit OS-18SRW-230VI | 1.5 tons18,000 Btu/h · Non-ducted | 76% | 2.49 | 9.8 | 21.0 | 12.0 | CEE 25CEE 26Xcel | 2 | 215887337 | Non-ducted, up to 1.5 tons | 55.3 | 69.0 | 41.6 | 69.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | OS-SR18-230VO | 2.53 | Non-ducted, up to 1.5 tons | 100% | 218752475 |
| Capacity retention at 5°F | OS-RMS18-230VO | 100% | Non-ducted, up to 1.5 tons | 87% | 217739001 |
| HSPF2 | OS-RMS18-230VO | 10.0 | Non-ducted, up to 1.5 tons | 64% | 217739001 |
| SEER2 | OS-RMS27-230VO | 23.0 | Non-ducted, 2.5–3 tons | 75% | 217739002 |
| EER2 | OS-RMS27-230VO | 12.9 | Non-ducted, 2.5–3 tons | 80% | 217739002 |
| Heating capacity at 5°F | OS-RMS18-230VO | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 93% | 217739001 |
OLMO size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 69.5(50 is the typical model of its size class)OS-RMS18-230VO2 of 6 models qualify · AHRI 217739001 | 69.2(50 is the typical model of its size class)OS-RMS18-230VO6 of 6 models have all five ratings · AHRI 217739001 |
| Non-ducted, 2 tons | 38.8(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models qualify · AHRI 218752476 | 34.1(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models have all five ratings · AHRI 218752476 |
| Non-ducted, 2.5–3 tons | 53.7(50 is the typical model of its size class)OS-RMS36-230VO2 of 3 models qualify · AHRI 217739004 | 64.2(50 is the typical model of its size class)OS-RMS27-230VO3 of 3 models have all five ratings · AHRI 217739002 |
| Non-ducted, 3.5–4.5 tons | 16.4(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models qualify · AHRI 217739003 | 43.7(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models have all five ratings · AHRI 217739003 |
Newest OLMO certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| OS-SR24-230VOOLMOwith ductless indoor unit OS-A24SRW-230VI | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 76% | 9.0 | 19.5 | CEE 25CEE 26Xcel | 2 | 218752476 |
| OS-SR18-230VOOLMO · SIERRAwith ductless indoor unit OS-A18SRW-230VI | 1.5 tons18,000 Btu/h · Non-ducted | 2.53 | 74% | 9.8 | 20.0 | CEE 25CEE 26Xcel | 2 | 218752475 |
| OS-SR12-230VOOLMOwith ductless indoor unit OS-A12SRW-230VI | 1 ton12,000 Btu/h · Non-ducted | 1.83 | 63% | 9.0 | 20.0 | CEE 25CEE 26 | 2 | 218752474 |
| OS-SR09-230VOOLMO · SIERRAwith ductless indoor unit OS-A09SRW-230VI | 1 ton9,000 Btu/h · Non-ducted | 2.11 | 60% | 9.0 | 22.5 | CEE 25CEE 26 | 2 | 218752473 |
| OS-SR12-115VOOLMOwith ductless indoor unit OS-A12SRW-115VI | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 51% | 8.0 | 20.0 | CEE 25 | 2 | 218752472 |
Compare OLMO
OLMO includes these brand names as listed in AHRI: OLMO. Standards are checked against published thresholds; program rules beyond ratings are not checked.