Hisense heat pump efficiency: 168 outdoor models compared
Hisense has 168 heat pump outdoor models certified with this refrigerant group, in 1,203 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Hisense makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 168
- AHRI certifications
- 1,203
- Efficiency index
- 54%
- Typical model vs same-size, same-type peers (194 models)
- Meet CEE 2025
- 79.8%
- 134 models
How Hisense compares with comparable models
- Hisense
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index194 models scored | 54% | 11th of 29 | — |
| COP at 5°F194 models scored | 59% | 10th of 29 | 2.00 |
| Capacity retention at 5°F194 models scored | 61% | 7th of 29 | 76% |
| HSPF2194 models scored | 51% | 16th of 29 | 9.0 |
| SEER2194 models scored | 57% | 13th of 29 | 20.0 |
| EER2194 models scored | 47% | 20th of 29 | 11.7 |
| Heating capacity at 5°F194 models scored | 57% | 11th of 29 | 18,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 79.8% | 134 |
| CEE 2026 Tier 1 (Split ASHP) | 75% | 126 |
| CEE Advanced Tier (Split ASHP) | 7.1% | 12 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 67.3% | 113 |
| DOE Cold Climate Heat Pump Challenge | 7.1% | 12 |
| ENERGY STAR Cold Climate | 53.6% | 90 |
Sizes and duct types offered
- Hisense (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 56% | 56% | 46% | 60% |
| Ducted, 2 tons | 14 | 46% | 68% | 44% | 49% |
| Ducted, 2.5 to 3 tons | 24 | 57% | 63% | 59% | 62% |
| Ducted, 3.5 to 4.5 tons | 28 | 54% | 58% | 57% | 65% |
| Ducted, 5 tons and up | 5 | 70% | 63% | 75% | 85% |
| Non-ducted, up to 1.5 tons | 75 | 57% | 64% | 53% | 56% |
| Non-ducted, 2 tons | 16 | 49% | 42% | 39% | 47% |
| Non-ducted, 2.5 to 3 tons | 15 | 46% | 42% | 34% | 42% |
| Non-ducted, 3.5 to 4.5 tons | 5 | 49% | 49% | 26% | 49% |
| Non-ducted, 5 tons and up | 1 | 84% | 97% | 98% | 60% |
Every Hisense model in the market
- Hisense models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Hisense in the cold
- All listed models (median, middle 50% and 80%)
- Hisense (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Hisense, 47°F | 99 | 100% | 100% | 100% | 100% | 100% |
| Hisense, 17°F | 99 | 58% | 67% | 76% | 92% | 97% |
| Hisense, 5°F | 99 | 58% | 69% | 71% | 77% | 90% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Hisense, 47°F | 99 | 2.82 | 2.93 | 3.17 | 3.4 | 3.72 |
| Hisense, 17°F | 99 | 1.99 | 2.11 | 2.3 | 2.42 | 2.51 |
| Hisense, 5°F | 99 | 1.82 | 1.9 | 2 | 2.15 | 2.4 |
Source: NEEP ccASHP list · as of
Top Hisense models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AVW-60F3DAH2Hisense · Hi-Comfort | 5 tons60,000 Btu/h · Non-ducted | 100% | 2.30 | 11.0 | 63,000 | 21.5 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618254 | Non-ducted, 5 tons and up | 98.3 |
| 2AVW-48F3DAH2Hisense · Hi-Comfort | 4 tons48,000 Btu/h · Non-ducted | 100% | 2.40 | 10.8 | 54,000 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618251 | Non-ducted, 3.5 to 4.5 tons | 94.7 |
| 3AVW-36F3DAH2Hisense · Hi-Comfort | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.45 | 10.8 | 42,000 | 23.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618248 | Non-ducted, 2.5 to 3 tons | 93.3 |
| 4AO-12U3T25PHISENSE · Hi-PROwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P2 | 1 ton12,000 Btu/h · Non-ducted | 102% | 2.25 | 11.8 | 12,200 | 30.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217727404 | Non-ducted, up to 1.5 tons | 91.8 |
| 5AS-09UW3TBW00HISENSE · Hi-Prowith ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P2 | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.25 | 11.8 | 12,200 | 32.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216739752 | Non-ducted, up to 1.5 tons | 90.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AS-09UW3TBW00HISENSE · Hi-Prowith ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P2 | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.25 | 11.8 | 32.0 | 18.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216739752 | Non-ducted, up to 1.5 tons | 95.0 | 90.7 | 99.4 | 90.7 |
| 2AO-12U3T25PHISENSE · Hi-PROwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P2 | 1 ton12,000 Btu/h · Non-ducted | 102% | 2.25 | 11.8 | 30.0 | 15.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217727404 | Non-ducted, up to 1.5 tons | 94.6 | 91.8 | 97.4 | 91.8 |
| 3AS-12UW3TBW00HISENSE · Hi-Prowith ductless indoor unit AS-12UW3TBW**00 | 1 ton12,000 Btu/h · Non-ducted | 100% | 2.25 | 11.8 | 30.0 | 15.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216739753 | Non-ducted, up to 1.5 tons | 94.1 | 90.7 | 97.4 | 90.7 |
| 4AVW-36F3DAH2Hisense · Hi-Comfort | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.45 | 10.8 | 23.0 | 13.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618248 | Non-ducted, 2.5 to 3 tons | 87.2 | 93.3 | 81.1 | 93.3 |
| 5AO-09U3T26U2HISENSE · Hi-ULTRAwith ductless indoor unit ASU-09U3THB25U | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.10 | 11.0 | 25.0 | 13.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218270893 | Non-ducted, up to 1.5 tons | 85.6 | 84.6 | 86.7 | 84.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AST-18UW3RXW00Also listed as AO-18U3R25E | 2.53 | Non-ducted, up to 1.5 tons | 100% | 217080957 |
| Capacity retention at 5°F | AVW-60F3DAH2 | 100% | Ducted, 5 tons and up | 100% | 216618253 |
| HSPF2 | AVW-60F3DAH2 | 10.1 | Ducted, 5 tons and up | 99% | 216618253 |
| SEER2 | AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2 | 32.0 | Non-ducted, up to 1.5 tons | 99% | 216739752 |
| EER2 | AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2 | 18.4 | Non-ducted, up to 1.5 tons | 100% | 216739752 |
| Heating capacity at 5°F | AVW-60F3DAH2 | 63,000 Btu/h | Ducted, 5 tons and up | 100% | 216618253 |
Hisense size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 217465404 | 68.5(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 217465404 |
| Ducted, 2 tons | 82.1(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 214802096 | 79.8(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 214802096 |
| Ducted, 2.5 to 3 tons | 88.1(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P18 of 24 models qualify · AHRI 214802097 | 83.0(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P24 of 24 models have all five ratings · AHRI 214802097 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U20 of 27 models qualify · AHRI 217469235 | 82.9(50 is the typical model of its size class)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 217269197 |
| Ducted, 5 tons and up | 88.6(50 is the typical model of its size class)AVW-60F3DAH26 of 6 models qualify · AHRI 216618253 | 80.9(50 is the typical model of its size class)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 214855379 |
| Non-ducted, up to 1.5 tons | 91.8(50 is the typical model of its size class)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P250 of 75 models qualify · AHRI 217727404 | 95.0(50 is the typical model of its size class)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P275 of 75 models have all five ratings · AHRI 216739752 |
| Non-ducted, 2 tons | 76.9(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U16 of 16 models qualify · AHRI 216019253 | 63.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0016 of 16 models have all five ratings · AHRI 214081399 |
| Non-ducted, 2.5 to 3 tons | 93.3(50 is the typical model of its size class)AVW-36F3DAH212 of 15 models qualify · AHRI 216618248 | 87.2(50 is the typical model of its size class)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 216618248 |
| Non-ducted, 3.5 to 4.5 tons | 94.7(50 is the typical model of its size class)AVW-48F3DAH24 of 5 models qualify · AHRI 216618251 | 82.5(50 is the typical model of its size class)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 216618251 |
| Non-ducted, 5 tons and up | 98.3(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models qualify · AHRI 216618254 | 83.7(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 216618254 |
Newest Hisense certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AOH-30U3R26SSHISENSEwith ducted air handler D(A,C,E)36D3D+TDR | 2.5 tons28,600 Btu/h · Ducted | 2.30 | 64% | 7.8 | 14.8 | None | 16 | 218857162 |
| AOH-30U3R25EHISENSEwith ducted air handler HG80*36+TXV+TD | 2.5 tons31,000 Btu/h · Ducted | 2.00 | 64% | 8.0 | 15.0 | None | 17 | 218829856 |
| AOH-48U3T25UHISENSEwith ducted air handler FE*TT4*48+TXV | 4 tons47,000 Btu/h · Ducted | 1.94 | 75% | 8.7 | 18.0 | CEE 25CEE 26XcelES CC | 63 | 218827224 |
| AOH-24U3T24PHISENSEwith ducted air handler SM7*25+TXV+TD | 1.5 tons18,000 Btu/h · Ducted | 1.94 | 114% | 8.2 | 16.0 | CEE 25CEE 26XcelES CC | 59 | 218821872 |
| AOH-24U3T25UHISENSEwith ducted air handler SM7*24+TXV | 1.5 tons18,000 Btu/h · Ducted | 1.50 | 61% | 7.5 | 14.3 | CEE 25CEE 26XcelES CC | 64 | 218821871 |
Compare Hisense