Skip to content

Fujitsu vs Hisense heat pumps

Measured against models of the same size and duct type, Hisense scores higher on 5 of the 6 ratings. Fujitsu has 180 outdoor models, Hisense has 168 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Fujitsu and Hisense on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Hisense scores higher on 5 of the 6 ratings.
  • Fujitsu
  • Hisense
  • Other ranked manufacturers
FujitsuHisense

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFujitsuHisense
Efficiency index53%median — · 16th ranked54%median — · 11th ranked
COP at 5°F58%median 2.08 · 12th ranked59%median 2.00 · 10th ranked
Capacity retention at 5°F48%median 54% · 20th ranked61%median 76% · 7th ranked
HSPF245%median 7.5 · 19th ranked51%median 9.0 · 16th ranked
SEER244%median 15.2 · 22nd ranked57%median 20.0 · 13th ranked
EER248% (higher)median 11.0 · 18th ranked47% (higher)median 11.7 · 20th ranked
Heating capacity at 5°F49%median 18,200 Btu/h · 17th ranked57%median 18,000 Btu/h · 11th ranked
Outdoor models180168
AHRI certifications2,0881,203

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFujitsuHisense
CEE 2025 Tier 1 (Split ASHP)33.3%60 models79.8%134 models
CEE 2026 Tier 1 (Split ASHP)32.2%58 models75%126 models
CEE Advanced Tier (Split ASHP)7.8%14 models7.1%12 models
Xcel Energy Colorado cold-climate ASHP (2025)30%54 models67.3%113 models
DOE Cold Climate Heat Pump Challenge7.8%14 models7.1%12 models
ENERGY STAR Cold Climate28.9%52 models53.6%90 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Fujitsu
  • Hisense
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFujitsuHisense
Ducted, up to 1.5 tons12 · index 58%11 · index 56%
Ducted, 2 tons17 · index 38%14 · index 46%
Ducted, 2.5 to 3 tons44 · index 40%24 · index 57%
Ducted, 3.5 to 4.5 tons57 · index 44%28 · index 54%
Ducted, 5 tons and up22 · index 34%5 · index 70%
Non-ducted, up to 1.5 tons27 · index 76%75 · index 57%
Non-ducted, 2 tons8 · index 76%16 · index 49%
Non-ducted, 2.5 to 3 tons11 · index 69%15 · index 46%
Non-ducted, 3.5 to 4.5 tons9 · index 63%5 · index 49%
Non-ducted, 5 tons and up1 · index 79%1 · index 84%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFujitsuCold-climate score, best modelHisenseCold-climate score, best model
Ducted, up to 1.5 tons87.7(50 is the typical model of its size class) (higher)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 21881479573.8(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 217465404
Ducted, 2 tons83.6(50 is the typical model of its size class) (higher)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 21880760282.1(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 214802096
Ducted, 2.5 to 3 tons87.1(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 21789571688.1(50 is the typical model of its size class) (higher)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P18 of 24 models qualify · AHRI 214802097
Ducted, 3.5 to 4.5 tons80.9(50 is the typical model of its size class)FOP1948MJAYCAwith indoor coil FCCA4821SYEA and furnace FF80TV407517UH10 of 57 models qualify · AHRI 21668720283.9(50 is the typical model of its size class) (higher)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U20 of 27 models qualify · AHRI 217469235
Ducted, 5 tons and up72.3(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 21846776988.6(50 is the typical model of its size class) (higher)AVW-60F3DAH26 of 6 models qualify · AHRI 216618253
Non-ducted, up to 1.5 tons98.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 21601825591.8(50 is the typical model of its size class)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P250 of 75 models qualify · AHRI 217727404
Non-ducted, 2 tons86.5(50 is the typical model of its size class) (higher)AOUH24KWAH36 of 8 models qualify · AHRI 21544769376.9(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U16 of 16 models qualify · AHRI 216019253
Non-ducted, 2.5 to 3 tons94.5(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 21789570893.3(50 is the typical model of its size class)AVW-36F3DAH212 of 15 models qualify · AHRI 216618248
Non-ducted, 3.5 to 4.5 tons77.1(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models qualify · AHRI 21789571094.7(50 is the typical model of its size class) (higher)AVW-48F3DAH24 of 5 models qualify · AHRI 216618251
Non-ducted, 5 tons and up72.0(50 is the typical model of its size class)AOUK060MSAN71 of 1 models qualify · AHRI 21846606398.3(50 is the typical model of its size class) (higher)AVW-60F3DAH21 of 1 models qualify · AHRI 216618254

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFujitsuAll-around score, best modelHisenseAll-around score, best model
Ducted, up to 1.5 tons90.1(50 is the typical model of its size class) (higher)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 21881479968.5(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 217465404
Ducted, 2 tons85.9(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 21544769479.8(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 214802096
Ducted, 2.5 to 3 tons86.3(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS31 of 44 models have all five ratings · AHRI 21789571683.0(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P24 of 24 models have all five ratings · AHRI 214802097
Ducted, 3.5 to 4.5 tons85.6(50 is the typical model of its size class) (higher)AOUH42KUAH1with ducted air handler ARUH42KUAS32 of 53 models have all five ratings · AHRI 21789571482.9(50 is the typical model of its size class)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 217269197
Ducted, 5 tons and up57.0(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA16 of 26 models have all five ratings · AHRI 21541549680.9(50 is the typical model of its size class) (higher)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 214855379
Non-ducted, up to 1.5 tons99.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 21601825595.0(50 is the typical model of its size class)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P275 of 75 models have all five ratings · AHRI 216739752
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)AOUH24KWAH37 of 8 models have all five ratings · AHRI 21544769363.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0016 of 16 models have all five ratings · AHRI 214081399
Non-ducted, 2.5 to 3 tons90.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 21789570887.2(50 is the typical model of its size class)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 216618248
Non-ducted, 3.5 to 4.5 tons80.2(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models have all five ratings · AHRI 21789571082.5(50 is the typical model of its size class) (higher)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 216618251
Non-ducted, 5 tons and up78.9(50 is the typical model of its size class)AOUK060MSAN71 of 1 models have all five ratings · AHRI 21846606383.7(50 is the typical model of its size class) (higher)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 216618254

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFujitsuHisense
COP at 5°Fbeats 100% · 2.62AOUH12KTAP1Non-ducted, up to 1.5 tonsbeats 100% · 2.53AST-18UW3RXW00Also listed as AO-18U3R25ENon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 102%AOUH42KUAH1Non-ducted, 3.5 to 4.5 tonsbeats 100% · 100%AVW-60F3DAH2Ducted, 5 tons and up
HSPF2beats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tonsbeats 99% · 10.1AVW-60F3DAH2Ducted, 5 tons and up
SEER2beats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tonsbeats 99% · 32.0AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons
EER2beats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tonsbeats 100% · 18.4AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tonsbeats 100% · 63,000 Btu/hAVW-60F3DAH2Ducted, 5 tons and up

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Fujitsu vs Hisense: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Fujitsu (median, middle 50%)
  • Hisense (median, middle 50%)
Heating capacity, % of its 47°F maximum73%71%COP at maximum capacity2.182.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Fujitsu: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F59100%100%100%100%100%
Fujitsu, 17°F5965%71%82%90%95%
Fujitsu, 5°F5959%66%73%86%94%
Fujitsu: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F592.52.753.213.564.12
Fujitsu, 17°F592.282.322.42.62.72
Fujitsu, 5°F5922.12.182.32.41
Hisense: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F99100%100%100%100%100%
Hisense, 17°F9958%67%76%92%97%
Hisense, 5°F9958%69%71%77%90%
Hisense: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F992.822.933.173.43.72
Hisense, 17°F991.992.112.32.422.51
Hisense, 5°F991.821.922.152.4

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report