Skip to content

AUX vs Hisense heat pumps

Measured against models of the same size and duct type, Hisense scores higher on 5 of the 6 ratings. AUX has 189 outdoor models, Hisense has 168 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AUX and Hisense on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Hisense scores higher on 5 of the 6 ratings.
  • AUX
  • Hisense
  • Other ranked manufacturers
AUXHisense

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAUXHisense
Efficiency index49%median — · 21st ranked54%median — · 11th ranked
COP at 5°F60% (higher)median 2.00 · 7th ranked59% (higher)median 2.00 · 10th ranked
Capacity retention at 5°F52%median 75% · 15th ranked61%median 76% · 7th ranked
HSPF240%median 9.0 · 25th ranked51%median 9.0 · 16th ranked
SEER248%median 20.0 · 18th ranked57%median 20.0 · 13th ranked
EER239%median 11.0 · 27th ranked47%median 11.7 · 20th ranked
Heating capacity at 5°F49%median 9,600 Btu/h · 18th ranked57%median 18,000 Btu/h · 11th ranked
Outdoor models189168
AHRI certifications2231,203

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAUXHisense
CEE 2025 Tier 1 (Split ASHP)68.3%129 models79.8%134 models
CEE 2026 Tier 1 (Split ASHP)66.1%125 models75%126 models
CEE Advanced Tier (Split ASHP)1.1%2 models7.1%12 models
Xcel Energy Colorado cold-climate ASHP (2025)65.6%124 models67.3%113 models
DOE Cold Climate Heat Pump Challenge1.1%2 models7.1%12 models
ENERGY STAR Cold Climate46.6%88 models53.6%90 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • AUX
  • Hisense
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAUXHisense
Ducted, up to 1.5 tons6 · index 60%11 · index 56%
Ducted, 2 tons4 · index 59%14 · index 46%
Ducted, 2.5 to 3 tons9 · index 63%24 · index 57%
Ducted, 3.5 to 4.5 tons5 · index 61%28 · index 54%
Ducted, 5 tons and upNone5 · index 70%
Non-ducted, up to 1.5 tons120 · index 46%75 · index 57%
Non-ducted, 2 tons33 · index 52%16 · index 49%
Non-ducted, 2.5 to 3 tons22 · index 46%15 · index 46%
Non-ducted, 3.5 to 4.5 tons2 · index 73%5 · index 49%
Non-ducted, 5 tons and upNone1 · index 84%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAUXCold-climate score, best modelHisenseCold-climate score, best model
Ducted, up to 1.5 tons75.4(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models qualify · AHRI 21603243773.8(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 217465404
Ducted, 2 tons62.8(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 21603243882.1(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 214802096
Ducted, 2.5 to 3 tons73.7(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 21603240088.1(50 is the typical model of its size class) (higher)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P18 of 24 models qualify · AHRI 214802097
Ducted, 3.5 to 4.5 tons77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 21603244083.9(50 is the typical model of its size class) (higher)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U20 of 27 models qualify · AHRI 217469235
Ducted, 5 tons and upNo models in this size class88.6(50 is the typical model of its size class)AVW-60F3DAH26 of 6 models qualify · AHRI 216618253
Non-ducted, up to 1.5 tons83.5(50 is the typical model of its size class)ASUM18HPMULO80 of 120 models qualify · AHRI 21429142891.8(50 is the typical model of its size class) (higher)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P250 of 75 models qualify · AHRI 217727404
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)ASUM24HPMULO16 of 33 models qualify · AHRI 21429143176.9(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U16 of 16 models qualify · AHRI 216019253
Non-ducted, 2.5 to 3 tons73.6(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 21409794193.3(50 is the typical model of its size class) (higher)AVW-36F3DAH212 of 15 models qualify · AHRI 216618248
Non-ducted, 3.5 to 4.5 tons60.3(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 21605094294.7(50 is the typical model of its size class) (higher)AVW-48F3DAH24 of 5 models qualify · AHRI 216618251
Non-ducted, 5 tons and upNo models in this size class98.3(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models qualify · AHRI 216618254

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAUXAll-around score, best modelHisenseAll-around score, best model
Ducted, up to 1.5 tons79.8(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 21603243768.5(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 217465404
Ducted, 2 tons78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 21603243879.8(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 214802096
Ducted, 2.5 to 3 tons81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 21603243983.0(50 is the typical model of its size class) (higher)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P24 of 24 models have all five ratings · AHRI 214802097
Ducted, 3.5 to 4.5 tons87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 21603244082.9(50 is the typical model of its size class)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 217269197
Ducted, 5 tons and upNo models in this size class80.9(50 is the typical model of its size class)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 214855379
Non-ducted, up to 1.5 tons84.3(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 21521892895.0(50 is the typical model of its size class) (higher)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P275 of 75 models have all five ratings · AHRI 216739752
Non-ducted, 2 tons87.2(50 is the typical model of its size class) (higher)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 21711527463.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0016 of 16 models have all five ratings · AHRI 214081399
Non-ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 21409794187.2(50 is the typical model of its size class) (higher)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 216618248
Non-ducted, 3.5 to 4.5 tons74.5(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 21605094282.5(50 is the typical model of its size class) (higher)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 216618251
Non-ducted, 5 tons and upNo models in this size class83.7(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 216618254

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAUXHisense
COP at 5°Fbeats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tonsbeats 100% · 2.53AST-18UW3RXW00Also listed as AO-18U3R25ENon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 108%ASUM24HPMULONon-ducted, 2 tonsbeats 100% · 100%AVW-60F3DAH2Ducted, 5 tons and up
HSPF2beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5 to 3 tonsbeats 99% · 10.1AVW-60F3DAH2Ducted, 5 tons and up
SEER2beats 100% · 22.0ASUM42HPMULODucted, 3.5 to 4.5 tonsbeats 99% · 32.0AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons
EER2beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tonsbeats 100% · 18.4AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hAM2-H18/2DR3BNon-ducted, up to 1.5 tonsbeats 100% · 63,000 Btu/hAVW-60F3DAH2Ducted, 5 tons and up

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
AUX vs Hisense: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • AUX (median, middle 50%)
  • Hisense (median, middle 50%)
Heating capacity, % of its 47°F maximum70%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
AUX: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F65100%100%100%100%100%
AUX, 17°F6567%70%73%79%85%
AUX, 5°F6562%65%70%73%83%
AUX: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F652.933.183.33.523.72
AUX, 17°F652.12.172.282.342.45
AUX, 5°F651.89222.12.18
Hisense: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F99100%100%100%100%100%
Hisense, 17°F9958%67%76%92%97%
Hisense, 5°F9958%69%71%77%90%
Hisense: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F992.822.933.173.43.72
Hisense, 17°F991.992.112.32.422.51
Hisense, 5°F991.821.922.152.4

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy