Both views use the same certified data. This device remembers your choice.
AUX vs Hisense heat pumps
Measured against models of the same size and duct type, Hisense scores higher on 5 of the 6 ratings. AUX has 189 outdoor models, Hisense has 168 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AUX
- Hisense
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AUX | Hisense |
|---|---|---|
| Efficiency index | 49%median — · 21st ranked | 54%median — · 11th ranked |
| COP at 5°F | 60% (higher)median 2.00 · 7th ranked | 59% (higher)median 2.00 · 10th ranked |
| Capacity retention at 5°F | 52%median 75% · 15th ranked | 61%median 76% · 7th ranked |
| HSPF2 | 40%median 9.0 · 25th ranked | 51%median 9.0 · 16th ranked |
| SEER2 | 48%median 20.0 · 18th ranked | 57%median 20.0 · 13th ranked |
| EER2 | 39%median 11.0 · 27th ranked | 47%median 11.7 · 20th ranked |
| Heating capacity at 5°F | 49%median 9,600 Btu/h · 18th ranked | 57%median 18,000 Btu/h · 11th ranked |
| Outdoor models | 189 | 168 |
| AHRI certifications | 223 | 1,203 |
Share of models meeting each standard
| Standard | AUX | Hisense |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.3%129 models | 79.8%134 models |
| CEE 2026 Tier 1 (Split ASHP) | 66.1%125 models | 75%126 models |
| CEE Advanced Tier (Split ASHP) | 1.1%2 models | 7.1%12 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 65.6%124 models | 67.3%113 models |
| DOE Cold Climate Heat Pump Challenge | 1.1%2 models | 7.1%12 models |
| ENERGY STAR Cold Climate | 46.6%88 models | 53.6%90 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AUX
- Hisense
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AUX | Hisense |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 60% | 11 · index 56% |
| Ducted, 2 tons | 4 · index 59% | 14 · index 46% |
| Ducted, 2.5 to 3 tons | 9 · index 63% | 24 · index 57% |
| Ducted, 3.5 to 4.5 tons | 5 · index 61% | 28 · index 54% |
| Ducted, 5 tons and up | None | 5 · index 70% |
| Non-ducted, up to 1.5 tons | 120 · index 46% | 75 · index 57% |
| Non-ducted, 2 tons | 33 · index 52% | 16 · index 49% |
| Non-ducted, 2.5 to 3 tons | 22 · index 46% | 15 · index 46% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 73% | 5 · index 49% |
| Non-ducted, 5 tons and up | None | 1 · index 84% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AUXCold-climate score, best model | HisenseCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.4(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models qualify · AHRI 216032437 | 73.8(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 217465404 |
| Ducted, 2 tons | 62.8(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 216032438 | 82.1(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 214802096 |
| Ducted, 2.5 to 3 tons | 73.7(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 216032400 | 88.1(50 is the typical model of its size class) (higher)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P18 of 24 models qualify · AHRI 214802097 |
| Ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 216032440 | 83.9(50 is the typical model of its size class) (higher)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U20 of 27 models qualify · AHRI 217469235 |
| Ducted, 5 tons and up | No models in this size class | 88.6(50 is the typical model of its size class)AVW-60F3DAH26 of 6 models qualify · AHRI 216618253 |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class)ASUM18HPMULO80 of 120 models qualify · AHRI 214291428 | 91.8(50 is the typical model of its size class) (higher)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P250 of 75 models qualify · AHRI 217727404 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class) (higher)ASUM24HPMULO16 of 33 models qualify · AHRI 214291431 | 76.9(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U16 of 16 models qualify · AHRI 216019253 |
| Non-ducted, 2.5 to 3 tons | 73.6(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 214097941 | 93.3(50 is the typical model of its size class) (higher)AVW-36F3DAH212 of 15 models qualify · AHRI 216618248 |
| Non-ducted, 3.5 to 4.5 tons | 60.3(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 216050942 | 94.7(50 is the typical model of its size class) (higher)AVW-48F3DAH24 of 5 models qualify · AHRI 216618251 |
| Non-ducted, 5 tons and up | No models in this size class | 98.3(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models qualify · AHRI 216618254 |
All-around best
| Size and duct type | AUXAll-around score, best model | HisenseAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.8(50 is the typical model of its size class) (higher)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 216032437 | 68.5(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 217465404 |
| Ducted, 2 tons | 78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 216032438 | 79.8(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 214802096 |
| Ducted, 2.5 to 3 tons | 81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 216032439 | 83.0(50 is the typical model of its size class) (higher)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P24 of 24 models have all five ratings · AHRI 214802097 |
| Ducted, 3.5 to 4.5 tons | 87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 216032440 | 82.9(50 is the typical model of its size class)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 217269197 |
| Ducted, 5 tons and up | No models in this size class | 80.9(50 is the typical model of its size class)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 214855379 |
| Non-ducted, up to 1.5 tons | 84.3(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 215218928 | 95.0(50 is the typical model of its size class) (higher)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P275 of 75 models have all five ratings · AHRI 216739752 |
| Non-ducted, 2 tons | 87.2(50 is the typical model of its size class) (higher)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 217115274 | 63.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0016 of 16 models have all five ratings · AHRI 214081399 |
| Non-ducted, 2.5 to 3 tons | 78.7(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 214097941 | 87.2(50 is the typical model of its size class) (higher)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 216618248 |
| Non-ducted, 3.5 to 4.5 tons | 74.5(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 216050942 | 82.5(50 is the typical model of its size class) (higher)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 216618251 |
| Non-ducted, 5 tons and up | No models in this size class | 83.7(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 216618254 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AUX | Hisense |
|---|---|---|
| COP at 5°F | beats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tons | beats 100% · 2.53AST-18UW3RXW00Also listed as AO-18U3R25ENon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 99% · 108%ASUM24HPMULONon-ducted, 2 tons | beats 100% · 100%AVW-60F3DAH2Ducted, 5 tons and up |
| HSPF2 | beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5 to 3 tons | beats 99% · 10.1AVW-60F3DAH2Ducted, 5 tons and up |
| SEER2 | beats 100% · 22.0ASUM42HPMULODucted, 3.5 to 4.5 tons | beats 99% · 32.0AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons |
| EER2 | beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tons | beats 100% · 18.4AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 21,800 Btu/hAM2-H18/2DR3BNon-ducted, up to 1.5 tons | beats 100% · 63,000 Btu/hAVW-60F3DAH2Ducted, 5 tons and up |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- AUX (median, middle 50%)
- Hisense (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 100% | 100% | 100% | 100% | 100% |
| AUX, 17°F | 65 | 67% | 70% | 73% | 79% | 85% |
| AUX, 5°F | 65 | 62% | 65% | 70% | 73% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 2.93 | 3.18 | 3.3 | 3.52 | 3.72 |
| AUX, 17°F | 65 | 2.1 | 2.17 | 2.28 | 2.34 | 2.45 |
| AUX, 5°F | 65 | 1.89 | 2 | 2 | 2.1 | 2.18 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Hisense, 47°F | 99 | 100% | 100% | 100% | 100% | 100% |
| Hisense, 17°F | 99 | 58% | 67% | 76% | 92% | 97% |
| Hisense, 5°F | 99 | 58% | 69% | 71% | 77% | 90% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Hisense, 47°F | 99 | 2.82 | 2.93 | 3.17 | 3.4 | 3.72 |
| Hisense, 17°F | 99 | 1.99 | 2.11 | 2.3 | 2.42 | 2.51 |
| Hisense, 5°F | 99 | 1.82 | 1.9 | 2 | 2.15 | 2.4 |
Source: NEEP ccASHP list · as of