Skip to content

Hisense vs Mitsubishi Electric heat pumps

Measured against models of the same size and duct type, Mitsubishi Electric scores higher on 4 of the 6 ratings. Hisense has 168 outdoor models, Mitsubishi Electric has 156 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Hisense and Mitsubishi Electric on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsubishi Electric scores higher on 4 of the 6 ratings.
  • Hisense
  • Mitsubishi Electric
  • Other ranked manufacturers
HisenseMitsubis…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHisenseMitsubishi Electric
Efficiency index54%median — · 11th ranked61%median — · 6th ranked
COP at 5°F59% (higher)median 2.00 · 10th ranked56% (higher)median 2.01 · 16th ranked
Capacity retention at 5°F61% (higher)median 76% · 7th ranked55% (higher)median 71% · 13th ranked
HSPF251%median 9.0 · 16th ranked67%median 10.0 · 5th ranked
SEER257%median 20.0 · 13th ranked63%median 20.0 · 3rd ranked
EER247%median 11.7 · 20th ranked61%median 12.5 · 7th ranked
Heating capacity at 5°F57%median 18,000 Btu/h · 11th ranked64%median 20,500 Btu/h · 6th ranked
Outdoor models168156
AHRI certifications1,203538

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHisenseMitsubishi Electric
CEE 2025 Tier 1 (Split ASHP)79.8%134 models80.8%126 models
CEE 2026 Tier 1 (Split ASHP)75%126 models80.8%126 models
CEE Advanced Tier (Split ASHP)7.1%12 models10.3%16 models
Xcel Energy Colorado cold-climate ASHP (2025)67.3%113 models66.7%104 models
DOE Cold Climate Heat Pump Challenge7.1%12 models10.3%16 models
ENERGY STAR Cold Climate53.6%90 models66%103 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Hisense
  • Mitsubishi Electric
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHisenseMitsubishi Electric
Ducted, up to 1.5 tons11 · index 56%24 · index 63%
Ducted, 2 tons14 · index 46%11 · index 59%
Ducted, 2.5 to 3 tons24 · index 57%29 · index 62%
Ducted, 3.5 to 4.5 tons28 · index 54%29 · index 56%
Ducted, 5 tons and up5 · index 70%10 · index 54%
Non-ducted, up to 1.5 tons75 · index 57%60 · index 65%
Non-ducted, 2 tons16 · index 49%13 · index 63%
Non-ducted, 2.5 to 3 tons15 · index 46%21 · index 61%
Non-ducted, 3.5 to 4.5 tons5 · index 49%18 · index 54%
Non-ducted, 5 tons and up1 · index 84%6 · index 66%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHisenseCold-climate score, best modelMitsubishi ElectricCold-climate score, best model
Ducted, up to 1.5 tons73.8(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 21746540485.9(50 is the typical model of its size class) (higher)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL11 of 24 models qualify · AHRI 215734918
Ducted, 2 tons82.1(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 21480209680.9(50 is the typical model of its size class)PUZ-AK24NLHZ2***with ducted air handler PAA-AA24NL8 of 10 models qualify · AHRI 218697033
Ducted, 2.5 to 3 tons88.1(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P18 of 24 models qualify · AHRI 21480209788.5(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL20 of 30 models qualify · AHRI 218697041
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class) (higher)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U20 of 27 models qualify · AHRI 21746923580.1(50 is the typical model of its size class)MXZ-SM48NLHZ-**18 of 29 models qualify · AHRI 217135880
Ducted, 5 tons and up88.6(50 is the typical model of its size class) (higher)AVW-60F3DAH26 of 6 models qualify · AHRI 21661825378.8(50 is the typical model of its size class)MXZ-SM60NLHZ-**6 of 10 models qualify · AHRI 217643004
Non-ducted, up to 1.5 tons91.8(50 is the typical model of its size class)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P250 of 75 models qualify · AHRI 21772740497.7(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ243 of 60 models qualify · AHRI 215611124
Non-ducted, 2 tons76.9(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U16 of 16 models qualify · AHRI 21601925390.5(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL10 of 13 models qualify · AHRI 218697024
Non-ducted, 2.5 to 3 tons93.3(50 is the typical model of its size class)AVW-36F3DAH212 of 15 models qualify · AHRI 21661824894.0(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL12 of 21 models qualify · AHRI 218697037
Non-ducted, 3.5 to 4.5 tons94.7(50 is the typical model of its size class) (higher)AVW-48F3DAH24 of 5 models qualify · AHRI 21661825178.4(50 is the typical model of its size class)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-13 of 18 models qualify · AHRI 215685467
Non-ducted, 5 tons and up98.3(50 is the typical model of its size class) (higher)AVW-60F3DAH21 of 1 models qualify · AHRI 21661825469.7(50 is the typical model of its size class)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models qualify · AHRI 217643000

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHisenseAll-around score, best modelMitsubishi ElectricAll-around score, best model
Ducted, up to 1.5 tons68.5(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 21746540479.2(50 is the typical model of its size class) (higher)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL23 of 23 models have all five ratings · AHRI 215734918
Ducted, 2 tons79.8(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 21480209684.6(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NL11 of 11 models have all five ratings · AHRI 218697028
Ducted, 2.5 to 3 tons83.0(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P24 of 24 models have all five ratings · AHRI 21480209793.8(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL30 of 30 models have all five ratings · AHRI 218697041
Ducted, 3.5 to 4.5 tons82.9(50 is the typical model of its size class) (higher)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 21726919770.7(50 is the typical model of its size class)MXZ-SM48NLHZ-**29 of 29 models have all five ratings · AHRI 217135880
Ducted, 5 tons and up80.9(50 is the typical model of its size class) (higher)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 21485537965.7(50 is the typical model of its size class)MXZ-SM60NLHZ-**10 of 10 models have all five ratings · AHRI 217643004
Non-ducted, up to 1.5 tons95.0(50 is the typical model of its size class)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P275 of 75 models have all five ratings · AHRI 21673975298.8(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ256 of 60 models have all five ratings · AHRI 215611124
Non-ducted, 2 tons63.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0016 of 16 models have all five ratings · AHRI 21408139989.4(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL12 of 13 models have all five ratings · AHRI 218697024
Non-ducted, 2.5 to 3 tons87.2(50 is the typical model of its size class)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 21661824892.9(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL21 of 21 models have all five ratings · AHRI 218697037
Non-ducted, 3.5 to 4.5 tons82.5(50 is the typical model of its size class)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 21661825185.7(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-18 of 18 models have all five ratings · AHRI 215685467
Non-ducted, 5 tons and up83.7(50 is the typical model of its size class) (higher)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 21661825468.7(50 is the typical model of its size class)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models have all five ratings · AHRI 217643000

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHisenseMitsubishi Electric
COP at 5°Fbeats 100% · 2.53AST-18UW3RXW00Also listed as AO-18U3R25ENon-ducted, up to 1.5 tonsbeats 100% · 2.74PUZ-AK42NL2***Non-ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 100%AVW-60F3DAH2Ducted, 5 tons and upbeats 99% · 140%MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
HSPF2beats 99% · 10.1AVW-60F3DAH2Ducted, 5 tons and upbeats 100% · 12.0MXZ-SM36NLHZ***Also listed as PUMY-HL36NKMU, MXZ-SM36NLHZ-Non-ducted, 2.5 to 3 tons
SEER2beats 99% · 32.0AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tonsbeats 100% · 35.0MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
EER2beats 100% · 18.4AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tonsbeats 100% · 21.5MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hAVW-60F3DAH2Ducted, 5 tons and upbeats 100% · 26,600 Btu/hMUZ-FX24NLHZ***Also listed as MUZ-FX24NLHZ2Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Hisense vs Mitsubishi Electric: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Hisense (median, middle 50%)
  • Mitsubishi Electric (median, middle 50%)
Heating capacity, % of its 47°F maximum71%69%COP at maximum capacity2.002.05

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Hisense: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F99100%100%100%100%100%
Hisense, 17°F9958%67%76%92%97%
Hisense, 5°F9958%69%71%77%90%
Hisense: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Hisense, 47°F992.822.933.173.43.72
Hisense, 17°F991.992.112.32.422.51
Hisense, 5°F991.821.922.152.4
Mitsubishi Electric: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsubishi Electric, 47°F134100%100%100%100%100%
Mitsubishi Electric, 17°F13458%64%73%87%94%
Mitsubishi Electric, 5°F13451%55%69%85%95%
Mitsubishi Electric: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsubishi Electric, 47°F1342.232.723.23.784.1
Mitsubishi Electric, 17°F1341.7922.242.612.87
Mitsubishi Electric, 5°F1341.81.82.052.22.53

Source: NEEP ccASHP list · as of