Both views use the same certified data. This device remembers your choice.
Fujitsu vs Mitsubishi Electric heat pumps
Measured against models of the same size and duct type, Mitsubishi Electric scores higher on 5 of the 6 ratings. Fujitsu has 180 outdoor models, Mitsubishi Electric has 156 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Fujitsu
- Mitsubishi Electric
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Fujitsu | Mitsubishi Electric |
|---|---|---|
| Efficiency index | 53%median — · 16th ranked | 61%median — · 6th ranked |
| COP at 5°F | 58% (higher)median 2.08 · 12th ranked | 56% (higher)median 2.01 · 16th ranked |
| Capacity retention at 5°F | 48%median 54% · 20th ranked | 55%median 71% · 13th ranked |
| HSPF2 | 45%median 7.5 · 19th ranked | 67%median 10.0 · 5th ranked |
| SEER2 | 44%median 15.2 · 22nd ranked | 63%median 20.0 · 3rd ranked |
| EER2 | 48%median 11.0 · 18th ranked | 61%median 12.5 · 7th ranked |
| Heating capacity at 5°F | 49%median 18,200 Btu/h · 17th ranked | 64%median 20,500 Btu/h · 6th ranked |
| Outdoor models | 180 | 156 |
| AHRI certifications | 2,088 | 538 |
Share of models meeting each standard
| Standard | Fujitsu | Mitsubishi Electric |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%60 models | 80.8%126 models |
| CEE 2026 Tier 1 (Split ASHP) | 32.2%58 models | 80.8%126 models |
| CEE Advanced Tier (Split ASHP) | 7.8%14 models | 10.3%16 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 30%54 models | 66.7%104 models |
| DOE Cold Climate Heat Pump Challenge | 7.8%14 models | 10.3%16 models |
| ENERGY STAR Cold Climate | 28.9%52 models | 66%103 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Fujitsu
- Mitsubishi Electric
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Fujitsu | Mitsubishi Electric |
|---|---|---|
| Ducted, up to 1.5 tons | 12 · index 58% | 24 · index 63% |
| Ducted, 2 tons | 17 · index 38% | 11 · index 59% |
| Ducted, 2.5 to 3 tons | 44 · index 40% | 29 · index 62% |
| Ducted, 3.5 to 4.5 tons | 57 · index 44% | 29 · index 56% |
| Ducted, 5 tons and up | 22 · index 34% | 10 · index 54% |
| Non-ducted, up to 1.5 tons | 27 · index 76% | 60 · index 65% |
| Non-ducted, 2 tons | 8 · index 76% | 13 · index 63% |
| Non-ducted, 2.5 to 3 tons | 11 · index 69% | 21 · index 61% |
| Non-ducted, 3.5 to 4.5 tons | 9 · index 63% | 18 · index 54% |
| Non-ducted, 5 tons and up | 1 · index 79% | 6 · index 66% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FujitsuCold-climate score, best model | Mitsubishi ElectricCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.7(50 is the typical model of its size class) (higher)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795 | 85.9(50 is the typical model of its size class)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL11 of 24 models qualify · AHRI 215734918 |
| Ducted, 2 tons | 83.6(50 is the typical model of its size class) (higher)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602 | 80.9(50 is the typical model of its size class)PUZ-AK24NLHZ2***with ducted air handler PAA-AA24NL8 of 10 models qualify · AHRI 218697033 |
| Ducted, 2.5 to 3 tons | 87.1(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716 | 88.5(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL20 of 30 models qualify · AHRI 218697041 |
| Ducted, 3.5 to 4.5 tons | 80.9(50 is the typical model of its size class) (higher)FOP1948MJAYCAwith indoor coil FCCA4821SYEA and furnace FF80TV407517UH10 of 57 models qualify · AHRI 216687202 | 80.1(50 is the typical model of its size class)MXZ-SM48NLHZ-**18 of 29 models qualify · AHRI 217135880 |
| Ducted, 5 tons and up | 72.3(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 218467769 | 78.8(50 is the typical model of its size class) (higher)MXZ-SM60NLHZ-**6 of 10 models qualify · AHRI 217643004 |
| Non-ducted, up to 1.5 tons | 98.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255 | 97.7(50 is the typical model of its size class)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ243 of 60 models qualify · AHRI 215611124 |
| Non-ducted, 2 tons | 86.5(50 is the typical model of its size class)AOUH24KWAH36 of 8 models qualify · AHRI 215447693 | 90.5(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL10 of 13 models qualify · AHRI 218697024 |
| Non-ducted, 2.5 to 3 tons | 94.5(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708 | 94.0(50 is the typical model of its size class)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL12 of 21 models qualify · AHRI 218697037 |
| Non-ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models qualify · AHRI 217895710 | 78.4(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-13 of 18 models qualify · AHRI 215685467 |
| Non-ducted, 5 tons and up | 72.0(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models qualify · AHRI 218466063 | 69.7(50 is the typical model of its size class)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models qualify · AHRI 217643000 |
All-around best
| Size and duct type | FujitsuAll-around score, best model | Mitsubishi ElectricAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 90.1(50 is the typical model of its size class) (higher)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799 | 79.2(50 is the typical model of its size class)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL23 of 23 models have all five ratings · AHRI 215734918 |
| Ducted, 2 tons | 85.9(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694 | 84.6(50 is the typical model of its size class)PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NL11 of 11 models have all five ratings · AHRI 218697028 |
| Ducted, 2.5 to 3 tons | 86.3(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS31 of 44 models have all five ratings · AHRI 217895716 | 93.8(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL30 of 30 models have all five ratings · AHRI 218697041 |
| Ducted, 3.5 to 4.5 tons | 85.6(50 is the typical model of its size class) (higher)AOUH42KUAH1with ducted air handler ARUH42KUAS32 of 53 models have all five ratings · AHRI 217895714 | 70.7(50 is the typical model of its size class)MXZ-SM48NLHZ-**29 of 29 models have all five ratings · AHRI 217135880 |
| Ducted, 5 tons and up | 57.0(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA16 of 26 models have all five ratings · AHRI 215415496 | 65.7(50 is the typical model of its size class) (higher)MXZ-SM60NLHZ-**10 of 10 models have all five ratings · AHRI 217643004 |
| Non-ducted, up to 1.5 tons | 99.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255 | 98.8(50 is the typical model of its size class)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ256 of 60 models have all five ratings · AHRI 215611124 |
| Non-ducted, 2 tons | 88.5(50 is the typical model of its size class)AOUH24KWAH37 of 8 models have all five ratings · AHRI 215447693 | 89.4(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL12 of 13 models have all five ratings · AHRI 218697024 |
| Non-ducted, 2.5 to 3 tons | 90.1(50 is the typical model of its size class)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708 | 92.9(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL21 of 21 models have all five ratings · AHRI 218697037 |
| Non-ducted, 3.5 to 4.5 tons | 80.2(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models have all five ratings · AHRI 217895710 | 85.7(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-18 of 18 models have all five ratings · AHRI 215685467 |
| Non-ducted, 5 tons and up | 78.9(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063 | 68.7(50 is the typical model of its size class)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models have all five ratings · AHRI 217643000 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Fujitsu | Mitsubishi Electric |
|---|---|---|
| COP at 5°F | beats 100% · 2.62AOUH12KTAP1Non-ducted, up to 1.5 tons | beats 100% · 2.74PUZ-AK42NL2***Non-ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 100% · 102%AOUH42KUAH1Non-ducted, 3.5 to 4.5 tons | beats 99% · 140%MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons |
| HSPF2 | beats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 100% · 12.0MXZ-SM36NLHZ***Also listed as PUMY-HL36NKMU, MXZ-SM36NLHZ-Non-ducted, 2.5 to 3 tons |
| SEER2 | beats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 100% · 35.0MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons |
| EER2 | beats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 100% · 21.5MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons | beats 100% · 26,600 Btu/hMUZ-FX24NLHZ***Also listed as MUZ-FX24NLHZ2Non-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Fujitsu (median, middle 50%)
- Mitsubishi Electric (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Fujitsu, 47°F | 59 | 100% | 100% | 100% | 100% | 100% |
| Fujitsu, 17°F | 59 | 65% | 71% | 82% | 90% | 95% |
| Fujitsu, 5°F | 59 | 59% | 66% | 73% | 86% | 94% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Fujitsu, 47°F | 59 | 2.5 | 2.75 | 3.21 | 3.56 | 4.12 |
| Fujitsu, 17°F | 59 | 2.28 | 2.32 | 2.4 | 2.6 | 2.72 |
| Fujitsu, 5°F | 59 | 2 | 2.1 | 2.18 | 2.3 | 2.41 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsubishi Electric, 47°F | 134 | 100% | 100% | 100% | 100% | 100% |
| Mitsubishi Electric, 17°F | 134 | 58% | 64% | 73% | 87% | 94% |
| Mitsubishi Electric, 5°F | 134 | 51% | 55% | 69% | 85% | 95% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsubishi Electric, 47°F | 134 | 2.23 | 2.72 | 3.2 | 3.78 | 4.1 |
| Mitsubishi Electric, 17°F | 134 | 1.79 | 2 | 2.24 | 2.61 | 2.87 |
| Mitsubishi Electric, 5°F | 134 | 1.8 | 1.8 | 2.05 | 2.2 | 2.53 |
Source: NEEP ccASHP list · as of