Friedrich vs Fujitsu heat pumps
Measured against models of the same size and duct type, Fujitsu scores higher on 6 of the 6 ratings. Friedrich has 188 outdoor models, Fujitsu has 179 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- Fujitsu
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | Fujitsu |
|---|---|---|
| Efficiency index | 39%median — · 28th ranked | 53%median — · 16th ranked |
| COP at 5°F | 46%median 1.99 · 22nd ranked | 60%median 2.10 · 8th ranked |
| Capacity retention at 5°F | 36%median 52% · 26th ranked | 48%median 56% · 19th ranked |
| HSPF2 | 31%median 7.5 · 28th ranked | 44%median 7.5 · 19th ranked |
| SEER2 | 34%median 15.2 · 28th ranked | 43%median 15.2 · 22nd ranked |
| EER2 | 37%median 10.6 · 27th ranked | 47%median 11.0 · 19th ranked |
| Heating capacity at 5°F | 35%median 17,000 Btu/h · 28th ranked | 50%median 18,100 Btu/h · 17th ranked |
| Outdoor models | 188 | 179 |
| AHRI certifications | 6,657 | 2,057 |
Share of models meeting each standard
| Standard | Friedrich | Fujitsu |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 26.6%50 models | 32.4%58 models |
| CEE 2026 Tier 1 (Split ASHP) | 23.9%45 models | 31.3%56 models |
| CEE Advanced Tier (Split ASHP) | 0.5%1 models | 7.8%14 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.3%40 models | 29.6%53 models |
| DOE Cold Climate Heat Pump Challenge | 0.5%1 models | 7.8%14 models |
| ENERGY STAR Cold Climate | 22.3%42 models | 26.8%48 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- Fujitsu
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | Fujitsu |
|---|---|---|
| Ducted, up to 1.5 tons | 21 · index 30% | 12 · index 57% |
| Ducted, 2 tons | 21 · index 31% | 17 · index 37% |
| Ducted, 2.5–3 tons | 46 · index 37% | 44 · index 42% |
| Ducted, 3.5–4.5 tons | 58 · index 41% | 56 · index 44% |
| Ducted, 5 tons and up | 21 · index 31% | 22 · index 32% |
| Non-ducted, up to 1.5 tons | 20 · index 55% | 27 · index 75% |
| Non-ducted, 2 tons | 5 · index 50% | 8 · index 74% |
| Non-ducted, 2.5–3 tons | 4 · index 47% | 11 · index 68% |
| Non-ducted, 3.5–4.5 tons | 2 · index 47% | 8 · index 62% |
| Non-ducted, 5 tons and up | None | 1 · index 78% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | FujitsuCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.0(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D5 of 21 models qualify · AHRI 217505657 | 87.4(50 is the typical model of its size class) (higher)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795 |
| Ducted, 2 tons | 70.3(50 is the typical model of its size class)RD18AY24AJVCwith indoor coil RCFY2417STANM and furnace FR801V0504A17UHU4 of 21 models qualify · AHRI 217176021 | 83.4(50 is the typical model of its size class) (higher)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 216891246 | 87.0(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716 |
| Ducted, 3.5–4.5 tons | 83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D8 of 57 models qualify · AHRI 217508872 | 79.3(50 is the typical model of its size class)AOUH42KUAS1with ducted air handler ARUH42KUAS9 of 56 models qualify · AHRI 215812202 |
| Ducted, 5 tons and up | 77.3(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR802V1255A24UHN1 of 22 models qualify · AHRI 218328124 | 71.9(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 218467769 |
| Non-ducted, up to 1.5 tons | 82.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 | 98.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255 |
| Non-ducted, 2 tons | 76.3(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 | 93.1(50 is the typical model of its size class) (higher)AOUK024SSAN77 of 8 models qualify · AHRI 216372779 |
| Non-ducted, 2.5–3 tons | 58.2(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 | 94.6(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708 |
| Non-ducted, 3.5–4.5 tons | 49.7(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 | 76.7(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS7 of 8 models qualify · AHRI 217895710 |
| Non-ducted, 5 tons and up | No models in this size class | 70.6(50 is the typical model of its size class)AOUK060MSAN71 of 1 models qualify · AHRI 218466063 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | FujitsuAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.4(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D20 of 20 models have all five ratings · AHRI 217505657 | 90.0(50 is the typical model of its size class) (higher)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799 |
| Ducted, 2 tons | 75.1(50 is the typical model of its size class)FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M421 of 21 models have all five ratings · AHRI 216551633 | 85.7(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694 |
| Ducted, 2.5–3 tons | 84.1(50 is the typical model of its size class)RD18AY36AJVCwith ducted air handler RH2VY3621MTACN30 of 46 models have all five ratings · AHRI 216613170 | 86.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS28 of 44 models have all five ratings · AHRI 217895716 |
| Ducted, 3.5–4.5 tons | 84.1(50 is the typical model of its size class)FRP19AY48AJVCwith indoor coil RCFY4821SEAAM and furnace FR802V0754A17UH32 of 54 models have all five ratings · AHRI 216551827 | 85.4(50 is the typical model of its size class) (higher)AOUH42KUAH1with ducted air handler ARUH42KUAS28 of 52 models have all five ratings · AHRI 217895714 |
| Ducted, 5 tons and up | 70.3(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN14 of 26 models have all five ratings · AHRI 218328406 | 56.6(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA14 of 26 models have all five ratings · AHRI 215415496 |
| Non-ducted, up to 1.5 tons | 83.9(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 | 99.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255 |
| Non-ducted, 2 tons | 61.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 | 88.0(50 is the typical model of its size class) (higher)AOUK024SSAN78 of 8 models have all five ratings · AHRI 216372779 |
| Non-ducted, 2.5–3 tons | 64.2(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 | 90.0(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708 |
| Non-ducted, 3.5–4.5 tons | 49.6(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 | 80.2(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS7 of 8 models have all five ratings · AHRI 217895710 |
| Non-ducted, 5 tons and up | No models in this size class | 77.9(50 is the typical model of its size class)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | Fujitsu |
|---|---|---|
| COP at 5°F | beats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tons | beats 100% · 3.03AOUK024SSAN7Non-ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons | beats 100% · 102%AOUH42KUAH1Non-ducted, 3.5–4.5 tons |
| HSPF2 | beats 86% · 10.0FRP19AY60AJVCDucted, 3.5–4.5 tons | beats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons |
| SEER2 | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tons | beats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons |
| EER2 | beats 96% · 13.0RD18AY36AJVCDucted, 2.5–3 tons | beats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons | beats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons |