Skip to content

AUX vs Fujitsu heat pumps

Measured against models of the same size and duct type, AUX scores higher on 3 of the 6 ratings. AUX has 189 outdoor models, Fujitsu has 180 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AUX and Fujitsu on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AUX scores higher on 3 of the 6 ratings.
  • AUX
  • Fujitsu
  • Other ranked manufacturers
AUXFujitsu

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAUXFujitsu
Efficiency index49%median — · 21st ranked53%median — · 16th ranked
COP at 5°F60% (higher)median 2.00 · 7th ranked58% (higher)median 2.08 · 12th ranked
Capacity retention at 5°F52% (higher)median 75% · 15th ranked48% (higher)median 54% · 20th ranked
HSPF240%median 9.0 · 25th ranked45%median 7.5 · 19th ranked
SEER248% (higher)median 20.0 · 18th ranked44% (higher)median 15.2 · 22nd ranked
EER239%median 11.0 · 27th ranked48%median 11.0 · 18th ranked
Heating capacity at 5°F49%median 9,600 Btu/h · 18th ranked49%median 18,200 Btu/h · 17th ranked
Outdoor models189180
AHRI certifications2232,088

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAUXFujitsu
CEE 2025 Tier 1 (Split ASHP)68.3%129 models33.3%60 models
CEE 2026 Tier 1 (Split ASHP)66.1%125 models32.2%58 models
CEE Advanced Tier (Split ASHP)1.1%2 models7.8%14 models
Xcel Energy Colorado cold-climate ASHP (2025)65.6%124 models30%54 models
DOE Cold Climate Heat Pump Challenge1.1%2 models7.8%14 models
ENERGY STAR Cold Climate46.6%88 models28.9%52 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • AUX
  • Fujitsu
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAUXFujitsu
Ducted, up to 1.5 tons6 · index 60%12 · index 58%
Ducted, 2 tons4 · index 59%17 · index 38%
Ducted, 2.5 to 3 tons9 · index 63%44 · index 40%
Ducted, 3.5 to 4.5 tons5 · index 61%57 · index 44%
Ducted, 5 tons and upNone22 · index 34%
Non-ducted, up to 1.5 tons120 · index 46%27 · index 76%
Non-ducted, 2 tons33 · index 52%8 · index 76%
Non-ducted, 2.5 to 3 tons22 · index 46%11 · index 69%
Non-ducted, 3.5 to 4.5 tons2 · index 73%9 · index 63%
Non-ducted, 5 tons and upNone1 · index 79%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAUXCold-climate score, best modelFujitsuCold-climate score, best model
Ducted, up to 1.5 tons75.4(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models qualify · AHRI 21603243787.7(50 is the typical model of its size class) (higher)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795
Ducted, 2 tons62.8(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 21603243883.6(50 is the typical model of its size class) (higher)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602
Ducted, 2.5 to 3 tons73.7(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 21603240087.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716
Ducted, 3.5 to 4.5 tons77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 21603244080.9(50 is the typical model of its size class) (higher)FOP1948MJAYCAwith indoor coil FCCA4821SYEA and furnace FF80TV407517UH10 of 57 models qualify · AHRI 216687202
Ducted, 5 tons and upNo models in this size class72.3(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 218467769
Non-ducted, up to 1.5 tons83.5(50 is the typical model of its size class)ASUM18HPMULO80 of 120 models qualify · AHRI 21429142898.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255
Non-ducted, 2 tons84.9(50 is the typical model of its size class)ASUM24HPMULO16 of 33 models qualify · AHRI 21429143186.5(50 is the typical model of its size class) (higher)AOUH24KWAH36 of 8 models qualify · AHRI 215447693
Non-ducted, 2.5 to 3 tons73.6(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 21409794194.5(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708
Non-ducted, 3.5 to 4.5 tons60.3(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 21605094277.1(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models qualify · AHRI 217895710
Non-ducted, 5 tons and upNo models in this size class72.0(50 is the typical model of its size class)AOUK060MSAN71 of 1 models qualify · AHRI 218466063

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAUXAll-around score, best modelFujitsuAll-around score, best model
Ducted, up to 1.5 tons79.8(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 21603243790.1(50 is the typical model of its size class) (higher)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799
Ducted, 2 tons78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 21603243885.9(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694
Ducted, 2.5 to 3 tons81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 21603243986.3(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS31 of 44 models have all five ratings · AHRI 217895716
Ducted, 3.5 to 4.5 tons87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 21603244085.6(50 is the typical model of its size class)AOUH42KUAH1with ducted air handler ARUH42KUAS32 of 53 models have all five ratings · AHRI 217895714
Ducted, 5 tons and upNo models in this size class57.0(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA16 of 26 models have all five ratings · AHRI 215415496
Non-ducted, up to 1.5 tons84.3(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 21521892899.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255
Non-ducted, 2 tons87.2(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 21711527488.5(50 is the typical model of its size class) (higher)AOUH24KWAH37 of 8 models have all five ratings · AHRI 215447693
Non-ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 21409794190.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708
Non-ducted, 3.5 to 4.5 tons74.5(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 21605094280.2(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models have all five ratings · AHRI 217895710
Non-ducted, 5 tons and upNo models in this size class78.9(50 is the typical model of its size class)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAUXFujitsu
COP at 5°Fbeats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tonsbeats 100% · 2.62AOUH12KTAP1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 108%ASUM24HPMULONon-ducted, 2 tonsbeats 100% · 102%AOUH42KUAH1Non-ducted, 3.5 to 4.5 tons
HSPF2beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5 to 3 tonsbeats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons
SEER2beats 100% · 22.0ASUM42HPMULODucted, 3.5 to 4.5 tonsbeats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons
EER2beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tonsbeats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hAM2-H18/2DR3BNon-ducted, up to 1.5 tonsbeats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
AUX vs Fujitsu: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • AUX (median, middle 50%)
  • Fujitsu (median, middle 50%)
Heating capacity, % of its 47°F maximum70%73%COP at maximum capacity2.002.18

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
AUX: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F65100%100%100%100%100%
AUX, 17°F6567%70%73%79%85%
AUX, 5°F6562%65%70%73%83%
AUX: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
AUX, 47°F652.933.183.33.523.72
AUX, 17°F652.12.172.282.342.45
AUX, 5°F651.89222.12.18
Fujitsu: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F59100%100%100%100%100%
Fujitsu, 17°F5965%71%82%90%95%
Fujitsu, 5°F5959%66%73%86%94%
Fujitsu: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F592.52.753.213.564.12
Fujitsu, 17°F592.282.322.42.62.72
Fujitsu, 5°F5922.12.182.32.41

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter