Both views use the same certified data. This device remembers your choice.
AUX heat pump efficiency: 189 outdoor models compared
AUX has 189 heat pump outdoor models certified with this refrigerant group, in 223 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AUX makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 189
- AHRI certifications
- 223
- Efficiency index
- 49%
- Typical model vs same-size, same-type peers (176 models)
- Meet CEE 2025
- 68.3%
- 129 models
How AUX compares with comparable models
- AUX
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index176 models scored | 49% | 21st of 29 | — |
| COP at 5°F201 models scored | 60% | 7th of 29 | 2.00 |
| Capacity retention at 5°F176 models scored | 52% | 15th of 29 | 75% |
| HSPF2201 models scored | 40% | 25th of 29 | 9.0 |
| SEER2201 models scored | 48% | 18th of 29 | 20.0 |
| EER2201 models scored | 39% | 27th of 29 | 11.0 |
| Heating capacity at 5°F181 models scored | 49% | 18th of 29 | 9,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.3% | 129 |
| CEE 2026 Tier 1 (Split ASHP) | 66.1% | 125 |
| CEE Advanced Tier (Split ASHP) | 1.1% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 65.6% | 124 |
| DOE Cold Climate Heat Pump Challenge | 1.1% | 2 |
| ENERGY STAR Cold Climate | 46.6% | 88 |
Sizes and duct types offered
- AUX (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 60% | 50% | 43% | 72% |
| Ducted, 2 tons | 4 | 59% | 37% | 68% | 76% |
| Ducted, 2.5 to 3 tons | 9 | 63% | 50% | 73% | 83% |
| Ducted, 3.5 to 4.5 tons | 5 | 61% | 60% | 78% | 67% |
| Non-ducted, up to 1.5 tons | 120 | 46% | 64% | 34% | 44% |
| Non-ducted, 2 tons | 33 | 52% | 57% | 44% | 48% |
| Non-ducted, 2.5 to 3 tons | 22 | 46% | 61% | 35% | 40% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 73% | 52% | 64% | 93% |
Every AUX model in the market
- AUX models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
AUX in the cold
- All listed models (median, middle 50% and 80%)
- AUX (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 100% | 100% | 100% | 100% | 100% |
| AUX, 17°F | 65 | 67% | 70% | 73% | 79% | 85% |
| AUX, 5°F | 65 | 62% | 65% | 70% | 73% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 2.93 | 3.18 | 3.3 | 3.52 | 3.72 |
| AUX, 17°F | 65 | 2.1 | 2.17 | 2.28 | 2.34 | 2.45 |
| AUX, 5°F | 65 | 1.89 | 2 | 2 | 2.1 | 2.18 |
Source: NEEP ccASHP list · as of
Top AUX models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASUM24HPMULOAUX · C-Series | 2 tons24,000 Btu/h · Non-ducted | 108% | 2.10 | 10.5 | 26,000 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214291431 | Non-ducted, 2 tons | 84.9 |
| 2AM3-H24/2DR3BAUX · C-Series | 2 tons24,000 Btu/h · Non-ducted | 100% | 2.10 | 10.5 | 26,000 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214097943 | Non-ducted, 2 tons | 83.7 |
| 3ASUM18HPMULOAUX · C-Series | 1.5 tons18,000 Btu/h · Non-ducted | 121% | 2.00 | 11.0 | 21,800 | 23.3 | CEE 25CEE 26XcelES CC | 3 | 214291428 | Non-ducted, up to 1.5 tons | 83.5 |
| 4AM2-H18/2DR3BAUX · C-Series | 1.5 tons18,000 Btu/h · Non-ducted | 104% | 2.00 | 11.0 | 21,800 | 23.3 | CEE 25CEE 26XcelES CC | 1 | 214097940 | Non-ducted, up to 1.5 tons | 81.6 |
| 5ASW-H18E3B2/*R3DI-D2AUX · M-Serieswith ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2 | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 15,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 215218928 | Non-ducted, up to 1.5 tons | 80.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASUM42HPMULOAUX · C-Series | 3.5 tons42,000 Btu/h · Ducted | 83% | 2.10 | 10.0 | 22.0 | 12.3 | CEE 25CEE 26XcelES CC | 3 | 216032440 | Ducted, 3.5 to 4.5 tons | 87.2 | 77.1 | 97.4 | 77.1 |
| 2ASW-H24F6A2/ *R3DI-D7AUX · C-Serieswith ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D7 | 2 tons22,400 Btu/h · Non-ducted | 85% | 2.10 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 217115274 | Non-ducted, 2 tons | 87.2 | 78.3 | 96.0 | 78.3 |
| 3AMAR24HP230V1COAUX · C-Serieswith ductless indoor unit AMAR24HP230V1CH | 2 tons22,400 Btu/h · Non-ducted | 89% | 2.09 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 214290024 | Non-ducted, 2 tons | 87.0 | 77.9 | 96.0 | 77.9 |
| 4ASUM24HPMULOAUX · C-Series | 2 tons24,000 Btu/h · Non-ducted | 108% | 2.10 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214291431 | Non-ducted, 2 tons | 86.2 | 84.9 | 87.5 | 84.9 |
| 5AM3-H24/2DR3BAUX · C-Series | 2 tons24,000 Btu/h · Non-ducted | 100% | 2.10 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214097943 | Non-ducted, 2 tons | 85.6 | 83.7 | 87.5 | 83.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AFEB09HP115V1CO | 2.52 | Non-ducted, up to 1.5 tons | 100% | 214290017 |
| Capacity retention at 5°F | ASUM24HPMULO | 108% | Non-ducted, 2 tons | 99% | 214291431 |
| HSPF2 | AM4-H36/2DR3BAlso listed as ASUM36HPMULO | 11.0 | Non-ducted, 2.5 to 3 tons | 96% | 214097941 |
| SEER2 | ASUM42HPMULO | 22.0 | Ducted, 3.5 to 4.5 tons | 100% | 216032440 |
| EER2 | AMAR24HP230V1CO | 14.0 | Non-ducted, 2 tons | 97% | 214290024 |
| Heating capacity at 5°F | AM2-H18/2DR3B | 21,800 Btu/h | Non-ducted, up to 1.5 tons | 99% | 214097940 |
AUX size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.4(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models qualify · AHRI 216032437 | 79.8(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 216032437 |
| Ducted, 2 tons | 62.8(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 216032438 | 78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 216032438 |
| Ducted, 2.5 to 3 tons | 73.7(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 216032400 | 81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 216032439 |
| Ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 216032440 | 87.2(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 216032440 |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class)ASUM18HPMULO80 of 120 models qualify · AHRI 214291428 | 84.3(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 215218928 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class)ASUM24HPMULO16 of 33 models qualify · AHRI 214291431 | 87.2(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 217115274 |
| Non-ducted, 2.5 to 3 tons | 73.6(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 214097941 | 78.7(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 214097941 |
| Non-ducted, 3.5 to 4.5 tons | 60.3(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 216050942 | 74.5(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 216050942 |
Newest AUX certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ASPR27HPMULOAUX · A-Series | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 66% | 9.5 | 22.0 | CEE 25CEE 26Xcel | 3 | 218799887 |
| ASW-H30H8A8/**R3DI-B9AUX · M serieswith ductless indoor unit ASW-H30H8A8/**R3DI-B9 | 2.5 tons30,000 Btu/h · Non-ducted | 1.85 | 73% | 9.0 | 20.0 | CEE 25CEE 26Xcel | 1 | 218746698 |
| ASW-H12C5C3/P*R3DI-C5AUX · P serieswith ductless indoor unit ASW-H12C5C3/P*R3DI-C5 | 1 ton12,000 Btu/h · Non-ducted | 1.85 | 75% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 218743571 |
| ASW-H12C5C2/P*R3DI-C5AUX · P serieswith ductless indoor unit ASW-H12C5C2/P*R3DI-C5 | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 75% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 218743570 |
| AS-H24F8A2/**R3DI-C1AUXwith ductless indoor unit AW-H24F8A2/**R3DI-C1 | 2 tons23,000 Btu/h · Non-ducted | 1.98 | — | 8.3 | 18.5 | None | 1 | 218647765 |
Compare AUX