XTRON heat pump efficiency: 11 outdoor models compared
XTRON has 11 heat pump outdoor models certified with this refrigerant group, in 27 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes XTRON makes. XTRON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 11
- AHRI certifications
- 27
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (16 models)
- Meet CEE 2025
- 72.7%
- 8 models
How XTRON compares with comparable models
- XTRON
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index16 models scored | 58% | Not ranked | — |
| COP at 5°F16 models scored | 60% | Not ranked | 2.00 |
| Capacity retention at 5°F16 models scored | 60% | Not ranked | 78% |
| HSPF216 models scored | 63% | Not ranked | 9.0 |
| SEER216 models scored | 68% | Not ranked | 18.0 |
| EER216 models scored | 42% | Not ranked | 11.3 |
| Heating capacity at 5°F16 models scored | 61% | Not ranked | 23,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 72.7% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 72.7% | 8 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 72.7% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 45.5% | 5 |
Sizes and duct types offered
- XTRON (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 54% | 56% | 46% | 64% |
| Ducted, 2 tons | 2 | 52% | 45% | 58% | 67% |
| Ducted, 2.5–3 tons | 5 | 62% | 60% | 71% | 82% |
| Ducted, 3.5–4.5 tons | 2 | 51% | 62% | 73% | 54% |
| Non-ducted, up to 1.5 tons | 1 | 60% | 63% | 66% | 58% |
| Non-ducted, 2 tons | 1 | 72% | 51% | 70% | 82% |
| Non-ducted, 2.5–3 tons | 3 | 58% | 73% | 54% | 55% |
Every XTRON model in the market
- XTRON models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top XTRON models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1XM4-H30/2DR3AXTRON · multi-Series | 2.5 tons30,000 Btu/h · Ducted | 77% | 2.10 | 9.5 | 23,000 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217606760 | Ducted, 2.5–3 tons | 73.8 |
| 2XHU48HPV1AOXTRONwith ducted air handler XHU48HPV1AI | 4 tons48,000 Btu/h · Ducted | 84% | 2.10 | 9.0 | 40,500 | 16.0 | None | 2 | 217606778 | Ducted, 3.5–4.5 tons | 72.3 |
| 3XM4-H36/2DR3AXTRON · multi-Series | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 10.0 | 25,200 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217606761 | Ducted, 2.5–3 tons | 70.3 |
| 4XM3-H24/2DR3AXTRON · multi-Series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 21,600 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 217606754 | Non-ducted, 2 tons | 67.5 |
| 5XM2-H18/2DR3AXTRON · multi-Series | 1.5 tons17,700 Btu/h · Non-ducted | 81% | 2.00 | 10.0 | 14,500 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 217606753 | Non-ducted, up to 1.5 tons | 64.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1XM4-H30/2DR3AXTRON · multi-Series | 2.5 tons30,000 Btu/h · Ducted | 77% | 2.10 | 9.5 | 20.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217606760 | Ducted, 2.5–3 tons | 80.7 | 73.8 | 87.7 | 73.8 |
| 2XM4-H36/2DR3AXTRON · multi-Series | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 10.0 | 20.0 | 11.6 | CEE 25CEE 26XcelES CC | 3 | 217606761 | Ducted, 2.5–3 tons | 72.2 | 70.3 | 74.0 | 70.3 |
| 3XM3-H24/2DR3AXTRON · multi-Series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 217606754 | Non-ducted, 2 tons | 71.8 | 67.5 | 76.1 | 67.5 |
| 4XM4-H30/2DR3AXTRON · multi-Series | 2.5 tons30,000 Btu/h · Non-ducted | 82% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 217606755 | Non-ducted, 2.5–3 tons | 66.6 | 57.4 | 75.8 | 62.1 |
| 5XM5-H42/2DR3AXTRON · multi-Series | 3 tons37,000 Btu/h · Ducted | 76% | 2.00 | 9.2 | 20.0 | 11.2 | CEE 25CEE 26XcelES CC | 3 | 217606762 | Ducted, 2.5–3 tons | 66.3 | 64.3 | 68.4 | 64.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | XM4-H30/2DR3A | 2.05 | Non-ducted, 2.5–3 tons | 83% | 217606765 |
| Capacity retention at 5°F | XM3-H24/2DR3A | 90% | Non-ducted, 2 tons | 79% | 217606754 |
| HSPF2 | XM4-H36/2DR3A | 10.0 | Ducted, 2.5–3 tons | 84% | 217606761 |
| SEER2 | XM4-H30/2DR3A | 20.0 | Ducted, 2.5–3 tons | 94% | 217606760 |
| EER2 | XM4-H30/2DR3A | 12.5 | Non-ducted, 2.5–3 tons | 75% | 217606755 |
| Heating capacity at 5°F | XM2-H18/2DR3A | 14,500 Btu/h | Non-ducted, up to 1.5 tons | 85% | 217606753 |
XTRON size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.6(50 is the typical model of its size class)XM2-H18/2DR3A2 of 2 models qualify · AHRI 217606758 | 61.1(50 is the typical model of its size class)XM2-H18/2DR3A2 of 2 models have all five ratings · AHRI 217606758 |
| Ducted, 2 tons | 59.1(50 is the typical model of its size class)XM3-H24/2DR3A2 of 2 models qualify · AHRI 217606759 | 66.1(50 is the typical model of its size class)XM3-H24/2DR3A2 of 2 models have all five ratings · AHRI 217606759 |
| Ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)XM4-H30/2DR3A5 of 5 models qualify · AHRI 217606760 | 80.7(50 is the typical model of its size class)XM4-H30/2DR3A5 of 5 models have all five ratings · AHRI 217606760 |
| Ducted, 3.5–4.5 tons | 72.3(50 is the typical model of its size class)XHU48HPV1AOwith ducted air handler XHU48HPV1AI2 of 2 models qualify · AHRI 217606778 | 53.2(50 is the typical model of its size class)XHU48HPV1AOwith ducted air handler XHU48HPV1AI2 of 2 models have all five ratings · AHRI 217606778 |
| Non-ducted, up to 1.5 tons | 64.5(50 is the typical model of its size class)XM2-H18/2DR3A1 of 1 models qualify · AHRI 217606753 | 59.7(50 is the typical model of its size class)XM2-H18/2DR3A1 of 1 models have all five ratings · AHRI 217606753 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class)XM3-H24/2DR3A1 of 1 models qualify · AHRI 217606754 | 71.8(50 is the typical model of its size class)XM3-H24/2DR3A1 of 1 models have all five ratings · AHRI 217606754 |
| Non-ducted, 2.5–3 tons | 62.1(50 is the typical model of its size class)XM4-H30/2DR3A3 of 3 models qualify · AHRI 217606765 | 66.6(50 is the typical model of its size class)XM4-H30/2DR3A3 of 3 models have all five ratings · AHRI 217606755 |
Newest XTRON certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| XHU60HPV1AOXTRONwith ducted air handler XHU60HPV1AI | 4.5 tons55,000 Btu/h · Ducted | 2.00 | 75% | 9.0 | 16.0 | None | 2 | 217729389 |
| XHU48HPV1AOXTRONwith ducted air handler XHU48HPV1AI | 4 tons48,000 Btu/h · Ducted | 2.10 | 84% | 9.0 | 16.0 | None | 2 | 217729388 |
| XHU36HPV1AOXTRONwith ducted air handler XHU36HPV1AI | 3 tons35,000 Btu/h · Ducted | 2.00 | 66% | 8.6 | 17.0 | None | 2 | 217729387 |
| XHU30HPV1AOXTRONwith ducted air handler XHU30HPV1AI | 2.5 tons30,000 Btu/h · Ducted | 1.89 | 69% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 2 | 217729386 |
| XHU24HPV1AOXTRONwith ducted air handler XHU24HPV1AI | 2 tons23,000 Btu/h · Ducted | 1.89 | 78% | 8.5 | 17.0 | CEE 25CEE 26Xcel | 2 | 217729385 |
Compare XTRON
XTRON includes these brand names as listed in AHRI: XTRON. Standards are checked against published thresholds; program rules beyond ratings are not checked.