Skip to content

AUFIT heat pump efficiency: 45 outdoor models compared

AUFIT has 45 heat pump outdoor models certified with this refrigerant group, in 61 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AUFIT makes. AUFIT has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
45
AHRI certifications
61
Efficiency index
53%
Typical model vs same-size, same-type peers (50 models)
Meet CEE 2025
84.4%
38 models

How AUFIT compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
AUFIT against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of AUFIT’s own modelsAUFIT is strongest on COP at 5°F (its typical model beats 64% of comparable models) and weakest on EER2 (38%).
  • AUFIT
  • Middle half of its models
  • Other ranked manufacturers
AUFIT

Source: AHRI Directory, NEEP · as of

Average peer percentile of AUFIT’s models
RatingBeats comparable modelsRankRaw median
Efficiency index50 models scored53%Not ranked—
COP at 5°F50 models scored64%Not ranked2.00
Capacity retention at 5°F50 models scored51%Not ranked75%
HSPF250 models scored52%Not ranked9.0
SEER250 models scored61%Not ranked22.0
EER250 models scored38%Not ranked11.3
Heating capacity at 5°F50 models scored54%Not ranked15,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
AUFIT’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • AUFIT (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons352%58%40%61%
Ducted, 2 tons348%43%54%59%
Ducted, 2.5–3 tons757%56%67%76%
Ducted, 3.5–4.5 tons451%62%73%54%
Non-ducted, up to 1.5 tons2052%71%47%61%
Non-ducted, 2 tons667%69%65%71%
Non-ducted, 2.5–3 tons741%62%34%42%

Every AUFIT model in the market

AUFIT’s 50 models with a known size and duct type, over the shape of the whole catalog.
AUFIT models by size and ratingColoured: AUFIT · grey shapes: all 14,508 models · lines: catalog medians by size
  • AUFIT models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 50 aufit models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top AUFIT models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 AUFIT cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ASW-H18E3B2/*R3DI-D2AUFIT · M-Serieswith ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D21.5 tons18,000 Btu/h · Non-ducted82%2.2510.515,00025.0CEE 25CEE 26XcelES CC1217902887Non-ducted, up to 1.5 tons79.2
2ASW-H24F6A2/ *R3DI-D7AUFIT · C-Serieswith ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D72 tons22,400 Btu/h · Non-ducted85%2.1010.520,40025.0CEE 25CEE 26XcelES CC1217902888Non-ducted, 2 tons77.4
3ASW-H24F8A2/*R3DI-C7AUFIT · M-Serieswith ductless indoor unit ASW-H24F8A2/*R3DI-C7Also listed as ASW-H24F8A2/**R3DI-C72 tons23,000 Btu/h · Non-ducted87%2.2010.020,80022.0CEE 25CEE 26XcelES CC1217902884Non-ducted, 2 tons77.2
4FM4-H30/2DR3AAUFIT · multi-Series2.5 tons30,000 Btu/h · Ducted77%2.109.523,00020.0CEE 25CEE 26XcelES CC3217606745Ducted, 2.5–3 tons73.8
5XHU36HPV1AOAUFITwith ducted air handler XHU36HPV1AIAlso listed as FHU48HPV1AO4 tons48,000 Btu/h · Ducted84%2.109.040,50016.0None1217606771Ducted, 3.5–4.5 tons72.3

All-around best

Top 5 AUFIT models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ASW-H24F6A2/ *R3DI-D7AUFIT · C-Serieswith ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D72 tons22,400 Btu/h · Non-ducted85%2.1010.525.014.0CEE 25CEE 26XcelES CC1217902888Non-ducted, 2 tons86.577.495.677.4
2ASW-H18E3B2/*R3DI-D2AUFIT · M-Serieswith ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D21.5 tons18,000 Btu/h · Non-ducted82%2.2510.525.014.0CEE 25CEE 26XcelES CC1217902887Non-ducted, up to 1.5 tons82.979.286.779.2
3FM4-H30/2DR3AAUFIT · multi-Series2.5 tons30,000 Btu/h · Ducted77%2.109.520.012.0CEE 25CEE 26XcelES CC3217606745Ducted, 2.5–3 tons80.773.887.773.8
4FM4-H36/2DR3AAUFIT · multi-Series3 tons36,000 Btu/h · Ducted70%2.1010.020.011.6CEE 25CEE 26XcelES CC3217606746Ducted, 2.5–3 tons72.270.374.070.3
5FM3-H24/2DR3AAUFIT · multi-Series2 tons24,000 Btu/h · Non-ducted90%2.0010.023.012.5CEE 25CEE 26XcelES CC3217606739Non-ducted, 2 tons71.867.576.167.5

Best model on each rating

AUFIT’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D22.25Non-ducted, up to 1.5 tons89%217902887
Capacity retention at 5°FFM3-H24/2DR3A90%Non-ducted, 2 tons79%217606739
HSPF2FM4-H36/2DR3A10.0Ducted, 2.5–3 tons84%217606746
SEER2ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D725.0Non-ducted, 2 tons95%217902888
EER2ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D714.0Non-ducted, 2 tons96%217902888
Heating capacity at 5°FASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D215,000 Btu/hNon-ducted, up to 1.5 tons86%217902887

All 45 AUFIT models in Explore

AUFIT size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
AUFIT: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons55.6(50 is the typical model of its size class)FM2-H18/2DR3A3 of 3 models qualify · AHRI 21760674361.1(50 is the typical model of its size class)FM2-H18/2DR3A3 of 3 models have all five ratings · AHRI 217606743
Ducted, 2 tons59.1(50 is the typical model of its size class)FM3-H24/2DR3A3 of 3 models qualify · AHRI 21760674466.1(50 is the typical model of its size class)FM3-H24/2DR3A3 of 3 models have all five ratings · AHRI 217606744
Ducted, 2.5–3 tons73.8(50 is the typical model of its size class)FM4-H30/2DR3A7 of 7 models qualify · AHRI 21760674580.7(50 is the typical model of its size class)FM4-H30/2DR3A7 of 7 models have all five ratings · AHRI 217606745
Ducted, 3.5–4.5 tons72.3(50 is the typical model of its size class)XHU36HPV1AOwith ducted air handler XHU36HPV1AIAlso listed as FHU48HPV1AO4 of 4 models qualify · AHRI 21760677153.2(50 is the typical model of its size class)XHU36HPV1AOwith ducted air handler XHU36HPV1AIAlso listed as FHU48HPV1AO4 of 4 models have all five ratings · AHRI 217606771
Non-ducted, up to 1.5 tons79.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D217 of 20 models qualify · AHRI 21790288782.9(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D220 of 20 models have all five ratings · AHRI 217902887
Non-ducted, 2 tons77.4(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D75 of 6 models qualify · AHRI 21790288886.5(50 is the typical model of its size class)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D76 of 6 models have all five ratings · AHRI 217902888
Non-ducted, 2.5–3 tons62.1(50 is the typical model of its size class)FM4-H30/2DR3A7 of 7 models qualify · AHRI 21760675066.6(50 is the typical model of its size class)FM4-H30/2DR3A7 of 7 models have all five ratings · AHRI 217606740

All-around board, every manufacturer

Newest AUFIT certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified AUFIT outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
ASW-H36I9A2/**R3DI-B8AUFIT · C-Serieswith ductless indoor unit ASW-H36I9A2/**R3DI-B83 tons33,600 Btu/h · Non-ducted2.0070%8.620.0CEE 25CEE 26XcelES CC1218647766
ASW-H12C5C3/**R3DI-C5AUFIT · M-Serieswith ductless indoor unit ASW-H12C5C3/**R3DI-C51 ton12,000 Btu/h · Non-ducted2.1075%9.522.0CEE 25CEE 26Xcel1218644953
ASW-H24F6A2/**R3DI-D7AUFIT · C-Serieswith ductless indoor unit ASW-H24F6A2/**R3DI-D72 tons22,400 Btu/h · Non-ducted2.1085%10.525.0CEE 25CEE 26XcelES CC1218644952
ASW-H18E3B2/**R3DI-D2AUFIT · M-Serieswith ductless indoor unit ASW-H18E3B2/**R3DI-D21.5 tons18,000 Btu/h · Non-ducted2.2582%10.525.0CEE 25CEE 26XcelES CC1218644951
ASW-H12C5B2/**R3DI-C9AUFIT · M-Serieswith ductless indoor unit ASW-H12C5B2/**R3DI-C91 ton12,000 Btu/h · Non-ducted2.1072%10.024.0CEE 25CEE 26Xcel1218644950

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare AUFIT

Manufacturers of a similar size, side by side.

AUFIT includes these brand names as listed in AHRI: AUFIT. Standards are checked against published thresholds; program rules beyond ratings are not checked.