OUTES vs XTRON heat pumps
Measured against models of the same size and duct type, XTRON scores higher on 4 of the 6 ratings. OUTES has 24 outdoor models, XTRON has 24 outdoor models. OUTES and XTRON have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- OUTES
- XTRON
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | OUTES | XTRON |
|---|---|---|
| Efficiency index | 56% (higher)median — | 51% (higher)median — |
| COP at 5°F | 60%median 2.00 | 60%median 2.00 |
| Capacity retention at 5°F | 50%median 73% | 59%median 78% |
| HSPF2 | 36%median 7.5 | 44%median 8.7 |
| SEER2 | 34%median 14.3 | 52%median 20.0 |
| EER2 | 52% (higher)median 11.4 | 36% (higher)median 10.7 |
| Heating capacity at 5°F | 53%median 26,300 Btu/h | 54%median 16,550 Btu/h |
| Outdoor models | 24 | 24 |
| AHRI certifications | 63 | 40 |
Share of models meeting each standard
| Standard | OUTES | XTRON |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 25%6 models | 62.5%15 models |
| CEE 2026 Tier 1 (Split ASHP) | 25%6 models | 62.5%15 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 25%6 models | 70.8%17 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 25%6 models | 37.5%9 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- OUTES
- XTRON
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | OUTES | XTRON |
|---|---|---|
| Ducted, up to 1.5 tons | 3 · index 26% | 2 · index 56% |
| Ducted, 2 tons | 5 · index 59% | 2 · index 52% |
| Ducted, 2.5 to 3 tons | 7 · index 58% | 5 · index 62% |
| Ducted, 3.5 to 4.5 tons | 9 · index 63% | 2 · index 51% |
| Non-ducted, up to 1.5 tons | None | 11 · index 43% |
| Non-ducted, 2 tons | None | 3 · index 49% |
| Non-ducted, 2.5 to 3 tons | None | 4 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | OUTESCold-climate score, best model | XTRONCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 56.9(50 is the typical model of its size class)XM2-H18/2DR3A2 of 2 models qualify · AHRI 217606758 |
| Ducted, 2 tons | 68.3(50 is the typical model of its size class) (higher)ORT-H24DEMR3-M01/SE1802 of 5 models qualify · AHRI 218389013 | 59.1(50 is the typical model of its size class)XM3-H24/2DR3A2 of 2 models qualify · AHRI 217606759 |
| Ducted, 2.5 to 3 tons | 64.6(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 7 models qualify · AHRI 218361292 | 73.7(50 is the typical model of its size class) (higher)XM4-H30/2DR3A5 of 5 models qualify · AHRI 217606760 |
| Ducted, 3.5 to 4.5 tons | 72.3(50 is the typical model of its size class)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models qualify · AHRI 216437867 | 72.4(50 is the typical model of its size class) (higher)XHU48HPV1AOwith ducted air handler XHU48HPV1AI2 of 2 models qualify · AHRI 217606778 |
| Non-ducted, up to 1.5 tons | No models in this size class | 66.1(50 is the typical model of its size class)XM2-H18/2DR3A8 of 11 models qualify · AHRI 217606753 |
| Non-ducted, 2 tons | No models in this size class | 68.5(50 is the typical model of its size class)XM3-H24/2DR3A2 of 3 models qualify · AHRI 217606754 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 63.1(50 is the typical model of its size class)XM4-H30/2DR3A4 of 4 models qualify · AHRI 217606765 |
All-around best
| Size and duct type | OUTESAll-around score, best model | XTRONAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 25.9(50 is the typical model of its size class)OTD-H18SMR6-A01/SE150with ducted air handler 26UCS(*,E,Q,R,W)*X1 of 3 models have all five ratings · AHRI 218147983 | 62.3(50 is the typical model of its size class) (higher)XM2-H18/2DR3A2 of 2 models have all five ratings · AHRI 217606758 |
| Ducted, 2 tons | 76.5(50 is the typical model of its size class) (higher)OTD-H36DMR3-B01/SE180with ducted air handler OAH-C24DMR3-A01/SE1803 of 5 models have all five ratings · AHRI 216437864 | 66.2(50 is the typical model of its size class)XM3-H24/2DR3A2 of 2 models have all five ratings · AHRI 217606759 |
| Ducted, 2.5 to 3 tons | 58.3(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 7 models have all five ratings · AHRI 218361292 | 80.8(50 is the typical model of its size class) (higher)XM4-H30/2DR3A5 of 5 models have all five ratings · AHRI 217606760 |
| Ducted, 3.5 to 4.5 tons | 73.3(50 is the typical model of its size class) (higher)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models have all five ratings · AHRI 216437867 | 53.5(50 is the typical model of its size class)XHU48HPV1AOwith ducted air handler XHU48HPV1AI2 of 2 models have all five ratings · AHRI 217606778 |
| Non-ducted, up to 1.5 tons | No models in this size class | 62.0(50 is the typical model of its size class)XM2-H18/2DR3A8 of 11 models have all five ratings · AHRI 217606753 |
| Non-ducted, 2 tons | No models in this size class | 73.3(50 is the typical model of its size class)XM3-H24/2DR3A3 of 3 models have all five ratings · AHRI 217606754 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 67.4(50 is the typical model of its size class)XM4-H30/2DR3A4 of 4 models have all five ratings · AHRI 217606755 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | OUTES | XTRON |
|---|---|---|
| COP at 5°F | beats 86% · 2.30OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons | beats 86% · 2.20XH18JDA2DI-19USNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 96% · 103%ORT-H24DEMR3-M01/SE180Ducted, 2 tons | beats 81% · 90%XM3-H24/2DR3ANon-ducted, 2 tons |
| HSPF2 | beats 74% · 9.2OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons | beats 84% · 10.0XM4-H36/2DR3ADucted, 2.5 to 3 tons |
| SEER2 | beats 81% · 18.5OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons | beats 94% · 20.0XM4-H30/2DR3ADucted, 2.5 to 3 tons |
| EER2 | beats 91% · 13.2OTD-H36DMR3-B01/SE180Ducted, 2 tons | beats 76% · 12.5XM4-H30/2DR3ANon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 94% · 24,600 Btu/hORT-H24DEMR3-M01/SE180Ducted, 2 tons | beats 86% · 14,500 Btu/hXM2-H18/2DR3ANon-ducted, up to 1.5 tons |