Skip to content

ORTECH vs OUTES heat pumps

Measured against models of the same size and duct type, ORTECH scores higher on 4 of the 6 ratings. ORTECH has 24 outdoor models, OUTES has 24 outdoor models. ORTECH and OUTES have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ORTECH and OUTES on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ORTECH scores higher on 4 of the 6 ratings.
  • ORTECH
  • OUTES
  • Other ranked manufacturers
ORTECHOUTES

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingORTECHOUTES
Efficiency index59% (higher)median —56% (higher)median —
COP at 5°F52%median 2.0060%median 2.00
Capacity retention at 5°F70% (higher)median 86%50% (higher)median 73%
HSPF265% (higher)median 9.536% (higher)median 7.5
SEER268% (higher)median 20.634% (higher)median 14.3
EER244%median 11.652%median 11.4
Heating capacity at 5°F73% (higher)median 24,500 Btu/h53% (higher)median 26,300 Btu/h
Outdoor models2424
AHRI certifications2463

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardORTECHOUTES
CEE 2025 Tier 1 (Split ASHP)83.3%20 models25%6 models
CEE 2026 Tier 1 (Split ASHP)83.3%20 models25%6 models
CEE Advanced Tier (Split ASHP)4.2%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)79.2%19 models25%6 models
DOE Cold Climate Heat Pump Challenge4.2%1 models0%0 models
ENERGY STAR Cold Climate75%18 models25%6 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • ORTECH
  • OUTES
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeORTECHOUTES
Ducted, up to 1.5 tons2 · index 53%3 · index 26%
Ducted, 2 tons2 · index 46%5 · index 59%
Ducted, 2.5 to 3 tons4 · index 50%7 · index 58%
Ducted, 3.5 to 4.5 tons4 · index 54%9 · index 63%
Non-ducted, up to 1.5 tons5 · index 60%None
Non-ducted, 2 tons3 · index 75%None
Non-ducted, 2.5 to 3 tons3 · index 67%None
Non-ducted, 3.5 to 4.5 tons1 · index 72%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeORTECHCold-climate score, best modelOUTESCold-climate score, best model
Ducted, up to 1.5 tons54.5(50 is the typical model of its size class)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models qualify · AHRI 218471060None on this board (0 of 3 models qualify)
Ducted, 2 tons59.4(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models qualify · AHRI 21847106168.2(50 is the typical model of its size class) (higher)ORT-H24DEMR3-M01/SE1802 of 5 models qualify · AHRI 218389013
Ducted, 2.5 to 3 tons69.4(50 is the typical model of its size class) (higher)OAH-AHU36K-CH-Owith ducted air handler OAH-AHU36K-CH-D2 of 4 models qualify · AHRI 21847106364.6(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 7 models qualify · AHRI 218361292
Ducted, 3.5 to 4.5 tons74.7(50 is the typical model of its size class) (higher)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models qualify · AHRI 21847106472.3(50 is the typical model of its size class)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models qualify · AHRI 216437867
Non-ducted, up to 1.5 tons81.6(50 is the typical model of its size class)OAH-MZ18K-208-CH-O4 of 5 models qualify · AHRI 218451243No models in this size class
Non-ducted, 2 tons83.7(50 is the typical model of its size class)OAH-MZ24K-208-CH-O3 of 3 models qualify · AHRI 218451244No models in this size class
Non-ducted, 2.5 to 3 tons73.6(50 is the typical model of its size class)OAH-MZ36K-208-CH-O3 of 3 models qualify · AHRI 218451245No models in this size class
Non-ducted, 3.5 to 4.5 tons50.9(50 is the typical model of its size class)OAH-MZ42K-208-CH-O1 of 1 models qualify · AHRI 218451246No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeORTECHAll-around score, best modelOUTESAll-around score, best model
Ducted, up to 1.5 tons57.0(50 is the typical model of its size class) (higher)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models have all five ratings · AHRI 21847106025.5(50 is the typical model of its size class)OTD-H18SMR6-A01/SE150with ducted air handler 26UCS(*,E,Q,R,W)*X1 of 3 models have all five ratings · AHRI 218147983
Ducted, 2 tons55.4(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models have all five ratings · AHRI 21847106176.5(50 is the typical model of its size class) (higher)OTD-H36DMR3-B01/SE180with ducted air handler OAH-C24DMR3-A01/SE1803 of 5 models have all five ratings · AHRI 216437864
Ducted, 2.5 to 3 tons60.7(50 is the typical model of its size class) (higher)OAH-AHU30K-CH-Owith ducted air handler OAH-AHU30K-CH-D4 of 4 models have all five ratings · AHRI 21847106258.2(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 7 models have all five ratings · AHRI 218361292
Ducted, 3.5 to 4.5 tons59.4(50 is the typical model of its size class)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models have all five ratings · AHRI 21847106473.3(50 is the typical model of its size class) (higher)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models have all five ratings · AHRI 216437867
Non-ducted, up to 1.5 tons75.0(50 is the typical model of its size class)OAH-MZ18K-208-CH-O4 of 5 models have all five ratings · AHRI 218451243No models in this size class
Non-ducted, 2 tons85.6(50 is the typical model of its size class)OAH-MZ24K-208-CH-O3 of 3 models have all five ratings · AHRI 218451244No models in this size class
Non-ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class)OAH-MZ36K-208-CH-O3 of 3 models have all five ratings · AHRI 218451245No models in this size class
Non-ducted, 3.5 to 4.5 tons72.3(50 is the typical model of its size class)OAH-MZ42K-208-CH-O1 of 1 models have all five ratings · AHRI 218451246No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingORTECHOUTES
COP at 5°Fbeats 81% · 2.12OAH-SZ12K-115-PR-ONon-ducted, up to 1.5 tonsbeats 86% · 2.30OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 96% · 100%OAH-MZ24K-208-CH-ONon-ducted, 2 tonsbeats 96% · 103%ORT-H24DEMR3-M01/SE180Ducted, 2 tons
HSPF2beats 96% · 11.0OAH-MZ36K-208-CH-ONon-ducted, 2.5 to 3 tonsbeats 74% · 9.2OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons
SEER2beats 94% · 24.0OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tonsbeats 81% · 18.5OTD-H60DMR3-C01/SE180Ducted, 3.5 to 4.5 tons
EER2beats 87% · 12.5OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tonsbeats 91% · 13.2OTD-H36DMR3-B01/SE180Ducted, 2 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hOAH-MZ18K-208-CH-ONon-ducted, up to 1.5 tonsbeats 94% · 24,600 Btu/hORT-H24DEMR3-M01/SE180Ducted, 2 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy