Both views use the same certified data. This device remembers your choice.
Maestrale vs ORTECH heat pumps
Measured against models of the same size and duct type, Maestrale scores higher on 4 of the 6 ratings. Maestrale has 24 outdoor models, ORTECH has 24 outdoor models. Maestrale and ORTECH have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Maestrale
- ORTECH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Maestrale | ORTECH |
|---|---|---|
| Efficiency index | 65% (higher)median — | 59% (higher)median — |
| COP at 5°F | 30%median 1.80 | 52%median 2.00 |
| Capacity retention at 5°F | 73% (higher)median 96% | 70% (higher)median 86% |
| HSPF2 | 73% (higher)median 10.3 | 65% (higher)median 9.5 |
| SEER2 | 81% (higher)median 23.8 | 68% (higher)median 20.6 |
| EER2 | 64% (higher)median 12.5 | 44% (higher)median 11.6 |
| Heating capacity at 5°F | 63%median 17,800 Btu/h | 73%median 24,500 Btu/h |
| Outdoor models | 24 | 24 |
| AHRI certifications | 24 | 24 |
Share of models meeting each standard
| Standard | Maestrale | ORTECH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%24 models | 83.3%20 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%24 models | 83.3%20 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 4.2%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%24 models | 79.2%19 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 4.2%1 models |
| ENERGY STAR Cold Climate | 33.3%8 models | 75%18 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Maestrale
- ORTECH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Maestrale | ORTECH |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 53% |
| Ducted, 2 tons | None | 2 · index 46% |
| Ducted, 2.5 to 3 tons | None | 4 · index 50% |
| Ducted, 3.5 to 4.5 tons | None | 4 · index 54% |
| Non-ducted, up to 1.5 tons | 14 · index 72% | 5 · index 60% |
| Non-ducted, 2 tons | 4 · index 59% | 3 · index 75% |
| Non-ducted, 2.5 to 3 tons | 4 · index 59% | 3 · index 67% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 42% | 1 · index 72% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | MaestraleCold-climate score, best model | ORTECHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 54.9(50 is the typical model of its size class)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models qualify · AHRI 218471060 |
| Ducted, 2 tons | No models in this size class | 59.5(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models qualify · AHRI 218471061 |
| Ducted, 2.5 to 3 tons | No models in this size class | 69.4(50 is the typical model of its size class)OAH-AHU36K-CH-Owith ducted air handler OAH-AHU36K-CH-D2 of 4 models qualify · AHRI 218471063 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 74.7(50 is the typical model of its size class)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models qualify · AHRI 218471064 |
| Non-ducted, up to 1.5 tons | 70.1(50 is the typical model of its size class)TSB20MBOR2J0X24Also listed as TSB20MBOR2J0X2414 of 14 models qualify · AHRI 218331913 | 81.6(50 is the typical model of its size class) (higher)OAH-MZ18K-208-CH-O4 of 5 models qualify · AHRI 218451243 |
| Non-ducted, 2 tons | 59.1(50 is the typical model of its size class)TSA24MAQU1J0X24-Owith ductless indoor unit TSA24MAQU1J0X24-IAlso listed as TSA24MAQU1JOX24-0, TSA24MAQU1J0X24-0, TSA24MAQU1J0X24-O4 of 4 models qualify · AHRI 218331912 | 83.7(50 is the typical model of its size class) (higher)OAH-MZ24K-208-CH-O3 of 3 models qualify · AHRI 218451244 |
| Non-ducted, 2.5 to 3 tons | 58.2(50 is the typical model of its size class)TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X244 of 4 models qualify · AHRI 218331928 | 73.6(50 is the typical model of its size class) (higher)OAH-MZ36K-208-CH-O3 of 3 models qualify · AHRI 218451245 |
| Non-ducted, 3.5 to 4.5 tons | 31.5(50 is the typical model of its size class)TSB45MBOR4J0X24Also listed as TSB45MBOR4J0X242 of 2 models qualify · AHRI 218331914 | 50.9(50 is the typical model of its size class) (higher)OAH-MZ42K-208-CH-O1 of 1 models qualify · AHRI 218451246 |
All-around best
| Size and duct type | MaestraleAll-around score, best model | ORTECHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 57.4(50 is the typical model of its size class)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models have all five ratings · AHRI 218471060 |
| Ducted, 2 tons | No models in this size class | 55.5(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models have all five ratings · AHRI 218471061 |
| Ducted, 2.5 to 3 tons | No models in this size class | 60.7(50 is the typical model of its size class)OAH-AHU30K-CH-Owith ducted air handler OAH-AHU30K-CH-D4 of 4 models have all five ratings · AHRI 218471062 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 59.4(50 is the typical model of its size class)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models have all five ratings · AHRI 218471064 |
| Non-ducted, up to 1.5 tons | 77.3(50 is the typical model of its size class) (higher)TSA09MAQU1J0X24-Owith ductless indoor unit TSA09MAQU1J0X24-IAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-O14 of 14 models have all five ratings · AHRI 218331911 | 75.0(50 is the typical model of its size class)OAH-MZ18K-208-CH-O4 of 5 models have all five ratings · AHRI 218451243 |
| Non-ducted, 2 tons | 58.5(50 is the typical model of its size class)TSA24MAQU1J0X24-Owith ductless indoor unit TSA24MAQU1J0X24-IAlso listed as TSA24MAQU1JOX24-0, TSA24MAQU1J0X24-0, TSA24MAQU1J0X24-O4 of 4 models have all five ratings · AHRI 218331912 | 85.6(50 is the typical model of its size class) (higher)OAH-MZ24K-208-CH-O3 of 3 models have all five ratings · AHRI 218451244 |
| Non-ducted, 2.5 to 3 tons | 65.9(50 is the typical model of its size class)TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X244 of 4 models have all five ratings · AHRI 218331928 | 78.7(50 is the typical model of its size class) (higher)OAH-MZ36K-208-CH-O3 of 3 models have all five ratings · AHRI 218451245 |
| Non-ducted, 3.5 to 4.5 tons | 42.3(50 is the typical model of its size class)TSB45MBOR4J0X24Also listed as TSB45MBOR4J0X242 of 2 models have all five ratings · AHRI 218331914 | 72.3(50 is the typical model of its size class) (higher)OAH-MZ42K-208-CH-O1 of 1 models have all five ratings · AHRI 218451246 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Maestrale | ORTECH |
|---|---|---|
| COP at 5°F | beats 64% · 2.00TSB20MBOR2J0X24Also listed as TSB20MBOR2J0X24Non-ducted, up to 1.5 tons | beats 81% · 2.12OAH-SZ12K-115-PR-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 93% · 106%TSA09MAQU1J0X24-OAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-ONon-ducted, up to 1.5 tons | beats 96% · 100%OAH-MZ24K-208-CH-ONon-ducted, 2 tons |
| HSPF2 | beats 81% · 10.5TSA09MAQU1J0X24-OAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-ONon-ducted, up to 1.5 tons | beats 96% · 11.0OAH-MZ36K-208-CH-ONon-ducted, 2.5 to 3 tons |
| SEER2 | beats 90% · 24.0TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X24Non-ducted, 2.5 to 3 tons | beats 94% · 24.0OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tons |
| EER2 | beats 88% · 14.5TSA09MAQU1J0X24-OAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-ONon-ducted, up to 1.5 tons | beats 87% · 12.5OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 91% · 17,800 Btu/hTSA18MAQU1J0X24-O*Also listed as TSA18MAQU1JOX24-0, TSA18MAQU1J0X24-0, TSA18MAQU1J0X24-ONon-ducted, up to 1.5 tons | beats 99% · 21,800 Btu/hOAH-MZ18K-208-CH-ONon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Maestrale (median, middle 50%)
- ORTECH (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Maestrale, 47°F | 24 | 100% | 100% | 100% | 100% | 100% |
| Maestrale, 17°F | 24 | 65% | 73% | 74% | 81% | 83% |
| Maestrale, 5°F | 24 | 57% | 65% | 67% | 71% | 72% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Maestrale, 47°F | 24 | 2.67 | 2.84 | 2.89 | 3.5 | 3.51 |
| Maestrale, 17°F | 24 | 1.99 | 2.01 | 2.07 | 2.25 | 2.4 |
| Maestrale, 5°F | 24 | 1.8 | 1.8 | 1.8 | 2 | 2 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ORTECH, 47°F | 24 | 100% | 100% | 100% | 100% | 100% |
| ORTECH, 17°F | 24 | 67% | 71% | 78% | 84% | 91% |
| ORTECH, 5°F | 24 | 63% | 67% | 71% | 81% | 90% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ORTECH, 47°F | 24 | 3.16 | 3.24 | 3.33 | 3.45 | 3.55 |
| ORTECH, 17°F | 24 | 2.03 | 2.1 | 2.19 | 2.3 | 2.35 |
| ORTECH, 5°F | 24 | 1.83 | 1.94 | 2 | 2 | 2.1 |
Source: NEEP ccASHP list · as of