Skip to content

ORTECH vs TRUENORTH heat pumps

Measured against models of the same size and duct type, ORTECH scores higher on 4 of the 6 ratings. ORTECH has 24 outdoor models, TRUENORTH has 24 outdoor models. ORTECH and TRUENORTH have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ORTECH and TRUENORTH on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ORTECH scores higher on 4 of the 6 ratings.
  • ORTECH
  • TRUENORTH
  • Other ranked manufacturers
ORTECHTRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingORTECHTRUENORTH
Efficiency index59% (higher)median —58% (higher)median —
COP at 5°F52% (higher)median 2.0050% (higher)median 2.00
Capacity retention at 5°F70%median 86%70%median 90%
HSPF265% (higher)median 9.555% (higher)median 10.0
SEER268% (higher)median 20.658% (higher)median 18.9
EER244%median 11.658%median 11.8
Heating capacity at 5°F73% (higher)median 24,500 Btu/h71% (higher)median 26,000 Btu/h
Outdoor models2424
AHRI certifications2480

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardORTECHTRUENORTH
CEE 2025 Tier 1 (Split ASHP)83.3%20 models95.8%23 models
CEE 2026 Tier 1 (Split ASHP)83.3%20 models95.8%23 models
CEE Advanced Tier (Split ASHP)4.2%1 models12.5%3 models
Xcel Energy Colorado cold-climate ASHP (2025)79.2%19 models95.8%23 models
DOE Cold Climate Heat Pump Challenge4.2%1 models12.5%3 models
ENERGY STAR Cold Climate75%18 models79.2%19 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • ORTECH
  • TRUENORTH
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeORTECHTRUENORTH
Ducted, up to 1.5 tons2 · index 53%3 · index 57%
Ducted, 2 tons2 · index 46%5 · index 54%
Ducted, 2.5 to 3 tons4 · index 50%5 · index 59%
Ducted, 3.5 to 4.5 tons4 · index 54%7 · index 73%
Non-ducted, up to 1.5 tons5 · index 60%4 · index 40%
Non-ducted, 2 tons3 · index 75%2 · index 52%
Non-ducted, 2.5 to 3 tons3 · index 67%2 · index 68%
Non-ducted, 3.5 to 4.5 tons1 · index 72%2 · index 49%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeORTECHCold-climate score, best modelTRUENORTHCold-climate score, best model
Ducted, up to 1.5 tons54.5(50 is the typical model of its size class)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models qualify · AHRI 21847106063.2(50 is the typical model of its size class) (higher)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models qualify · AHRI 218853808
Ducted, 2 tons59.4(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models qualify · AHRI 21847106176.2(50 is the typical model of its size class) (higher)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models qualify · AHRI 218853786
Ducted, 2.5 to 3 tons69.4(50 is the typical model of its size class) (higher)OAH-AHU36K-CH-Owith ducted air handler OAH-AHU36K-CH-D2 of 4 models qualify · AHRI 21847106352.0(50 is the typical model of its size class)WLWHD(36)ND6MO3 of 3 models qualify · AHRI 218593172
Ducted, 3.5 to 4.5 tons74.7(50 is the typical model of its size class)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models qualify · AHRI 21847106485.1(50 is the typical model of its size class) (higher)GUD60W2/NHE-D(U)with ducted air handler GUD60AH2/E-D(U)Also listed as WLUD60W2/NHE-D(U)6 of 7 models qualify · AHRI 218853784
Non-ducted, up to 1.5 tons81.6(50 is the typical model of its size class) (higher)OAH-MZ18K-208-CH-O4 of 5 models qualify · AHRI 21845124363.3(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models qualify · AHRI 218593163
Non-ducted, 2 tons83.7(50 is the typical model of its size class) (higher)OAH-MZ24K-208-CH-O3 of 3 models qualify · AHRI 21845124468.5(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models qualify · AHRI 218593164
Non-ducted, 2.5 to 3 tons73.6(50 is the typical model of its size class)OAH-MZ36K-208-CH-O3 of 3 models qualify · AHRI 21845124577.8(50 is the typical model of its size class) (higher)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 218593166
Non-ducted, 3.5 to 4.5 tons50.9(50 is the typical model of its size class)OAH-MZ42K-208-CH-O1 of 1 models qualify · AHRI 21845124667.0(50 is the typical model of its size class) (higher)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 218593167

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeORTECHAll-around score, best modelTRUENORTHAll-around score, best model
Ducted, up to 1.5 tons57.0(50 is the typical model of its size class)OAH-AHU18K-CH-Owith ducted air handler OAH-AHU18K-CH-D2 of 2 models have all five ratings · AHRI 21847106064.4(50 is the typical model of its size class) (higher)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models have all five ratings · AHRI 218853808
Ducted, 2 tons55.4(50 is the typical model of its size class)OAH-AHU24K-CH-Owith ducted air handler OAH-AHU24K-CH-D2 of 2 models have all five ratings · AHRI 21847106168.6(50 is the typical model of its size class) (higher)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853786
Ducted, 2.5 to 3 tons60.7(50 is the typical model of its size class)OAH-AHU30K-CH-Owith ducted air handler OAH-AHU30K-CH-D4 of 4 models have all five ratings · AHRI 21847106261.6(50 is the typical model of its size class) (higher)WLWHD(30)ND6MO3 of 3 models have all five ratings · AHRI 218593171
Ducted, 3.5 to 4.5 tons59.4(50 is the typical model of its size class)OAH-AHU48K-CH-Owith ducted air handler OAH-AHU48K-CH-D4 of 4 models have all five ratings · AHRI 21847106480.0(50 is the typical model of its size class) (higher)GUD48W2/NHE-D(U)with ducted air handler GUD48AH2/E-D(U)Also listed as GUD60W2/NHE-D(U), WLUD48W2/NHE-D(U), WLUD60W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853785
Non-ducted, up to 1.5 tons75.0(50 is the typical model of its size class) (higher)OAH-MZ18K-208-CH-O4 of 5 models have all five ratings · AHRI 21845124355.2(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models have all five ratings · AHRI 218593163
Non-ducted, 2 tons85.6(50 is the typical model of its size class) (higher)OAH-MZ24K-208-CH-O3 of 3 models have all five ratings · AHRI 21845124469.3(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models have all five ratings · AHRI 218593164
Non-ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class) (higher)OAH-MZ36K-208-CH-O3 of 3 models have all five ratings · AHRI 21845124571.2(50 is the typical model of its size class)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593165
Non-ducted, 3.5 to 4.5 tons72.3(50 is the typical model of its size class) (higher)OAH-MZ42K-208-CH-O1 of 1 models have all five ratings · AHRI 21845124667.8(50 is the typical model of its size class)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593167

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingORTECHTRUENORTH
COP at 5°Fbeats 81% · 2.12OAH-SZ12K-115-PR-ONon-ducted, up to 1.5 tonsbeats 87% · 2.10WLWHD(36)ND6MONon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 96% · 100%OAH-MZ24K-208-CH-ONon-ducted, 2 tonsbeats 94% · 100%GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)Ducted, 3.5 to 4.5 tons
HSPF2beats 96% · 11.0OAH-MZ36K-208-CH-ONon-ducted, 2.5 to 3 tonsbeats 91% · 10.5GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)Ducted, 3.5 to 4.5 tons
SEER2beats 94% · 24.0OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tonsbeats 91% · 20.0GUD60W2/NHG-D(U)Also listed as WLUD60W2/NHG-D(U)Ducted, 3.5 to 4.5 tons
EER2beats 87% · 12.5OAH-MZ42K-208-CH-ONon-ducted, 3.5 to 4.5 tonsbeats 95% · 13.0WLWHD(42)ND6MONon-ducted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hOAH-MZ18K-208-CH-ONon-ducted, up to 1.5 tonsbeats 98% · 54,000 Btu/hGUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)Ducted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ORTECH vs TRUENORTH: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ORTECH (median, middle 50%)
  • TRUENORTH (median, middle 50%)
Heating capacity, % of its 47°F maximum71%84%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
ORTECH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ORTECH, 47°F24100%100%100%100%100%
ORTECH, 17°F2467%71%78%84%91%
ORTECH, 5°F2463%67%71%81%90%
ORTECH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ORTECH, 47°F243.163.243.333.453.55
ORTECH, 17°F242.032.12.192.32.35
ORTECH, 5°F241.831.94222.1
TRUENORTH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F23100%100%100%100%100%
TRUENORTH, 17°F2374%82%86%91%97%
TRUENORTH, 5°F2370%73%84%98%99%
TRUENORTH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F233.033.193.333.513.58
TRUENORTH, 17°F232.082.322.42.562.67
TRUENORTH, 5°F231.851.9722.092.1

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter