Skip to content

TRUENORTH heat pump efficiency: 10 outdoor models compared

TRUENORTH has 10 heat pump outdoor models certified with this refrigerant group, in 22 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUENORTH makes. TRUENORTH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
10
AHRI certifications
22
Efficiency index
53%
Typical model vs same-size, same-type peers (16 models)
Meet CEE 2025
90%
9 models

How TRUENORTH compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TRUENORTH against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of TRUENORTH’s own modelsTRUENORTH is strongest on EER2 (its typical model beats 63% of comparable models) and weakest on HSPF2 (38%).
  • TRUENORTH
  • Middle half of its models
  • Other ranked manufacturers
TRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile of TRUENORTH’s models
RatingBeats comparable modelsRankRaw median
Efficiency index16 models scored53%Not ranked—
COP at 5°F16 models scored54%Not ranked2.00
Capacity retention at 5°F16 models scored59%Not ranked76%
HSPF216 models scored38%Not ranked9.4
SEER216 models scored50%Not ranked20.8
EER216 models scored63%Not ranked12.0
Heating capacity at 5°F16 models scored57%Not ranked19,200 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TRUENORTH’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • TRUENORTH (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons149%43%23%60%
Ducted, 2 tons155%30%36%55%
Ducted, 2.5–3 tons260%31%46%69%
Ducted, 3.5–4.5 tons268%63%48%82%
Non-ducted, up to 1.5 tons437%41%28%34%
Non-ducted, 2 tons250%40%41%37%
Non-ducted, 2.5–3 tons268%86%59%49%
Non-ducted, 3.5–4.5 tons252%89%22%37%

Every TRUENORTH model in the market

TRUENORTH’s 16 models with a known size and duct type, over the shape of the whole catalog.
TRUENORTH models by size and ratingColoured: TRUENORTH · grey shapes: all 14,508 models · lines: catalog medians by size
  • TRUENORTH models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 16 truenorth models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top TRUENORTH models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 TRUENORTH cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1WLWHD(36)ND6MOTRUENORTH3 tons36,000 Btu/h · Non-ducted100%2.1010.036,00021.0CEE 25CEE 26CEE AdvXcelDOE3218593166Non-ducted, 2.5–3 tons77.2
2WLWHD(30)ND6MOTRUENORTH2.5 tons28,400 Btu/h · Non-ducted90%2.0710.027,00021.0CEE 25CEE 26Xcel3218593165Non-ducted, 2.5–3 tons69.8
3WLWHD(24)ND6MOTRUENORTH2 tons24,000 Btu/h · Non-ducted90%2.0010.021,60021.0CEE 25CEE 26Xcel3218593164Non-ducted, 2 tons67.5
4WLWHD(42)ND6MOTRUENORTH3.5 tons42,000 Btu/h · Non-ducted90%2.1010.037,80021.0CEE 25CEE 26Xcel3218593167Non-ducted, 3.5–4.5 tons66.5
5WLWHD(18)ND6MOTRUENORTH1.5 tons18,000 Btu/h · Non-ducted77%2.0010.013,80021.0CEE 25CEE 26Xcel3218593163Non-ducted, up to 1.5 tons61.4

All-around best

Top 5 TRUENORTH models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1WLWHD(30)ND6MOTRUENORTH2.5 tons28,400 Btu/h · Non-ducted90%2.0710.021.013.6CEE 25CEE 26Xcel3218593165Non-ducted, 2.5–3 tons70.569.871.269.8
2WLWHD(42)ND6MOTRUENORTH3.5 tons42,000 Btu/h · Ducted86%1.908.118.012.0CEE 25CEE 26Xcel3218593173Ducted, 3.5–4.5 tons69.155.782.555.7
3WLWHD(42)ND6MOTRUENORTH3.5 tons42,000 Btu/h · Non-ducted90%2.1010.021.013.0CEE 25CEE 26Xcel3218593167Non-ducted, 3.5–4.5 tons67.766.568.866.5
4WLWHD(24)ND6MOTRUENORTH2 tons24,000 Btu/h · Non-ducted90%2.0010.021.013.3CEE 25CEE 26Xcel3218593164Non-ducted, 2 tons67.667.567.867.5
5WLWHD(60)ND6MOTRUENORTH4.5 tons55,000 Btu/h · Ducted56%2.308.019.011.7CEE 25CEE 263218593179Ducted, 3.5–4.5 tons67.655.180.2Not a pick

Best model on each rating

TRUENORTH’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FWLWHD(60)ND6MO2.20Non-ducted, 3.5–4.5 tons96%218593180
Capacity retention at 5°FWLWHD(36)ND6MO100%Non-ducted, 2.5–3 tons81%218593166
HSPF2WLWHD(24)ND6MO10.0Non-ducted, 2 tons69%218593164
SEER2WLWHD(60)ND6MO19.0Ducted, 3.5–4.5 tons85%218593179
EER2WLWHD(42)ND6MO13.0Non-ducted, 3.5–4.5 tons94%218593167
Heating capacity at 5°FWLWHD(36)ND6MO36,000 Btu/hNon-ducted, 2.5–3 tons86%218593166

All 10 TRUENORTH models in Explore

TRUENORTH size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TRUENORTH: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons39.3(50 is the typical model of its size class)WLWHD(18)ND6MO1 of 1 models qualify · AHRI 21859316848.6(50 is the typical model of its size class)WLWHD(18)ND6MO1 of 1 models have all five ratings · AHRI 218593168
Ducted, 2 tons49.0(50 is the typical model of its size class)WLWHD(24)ND6MO1 of 1 models qualify · AHRI 21859317054.7(50 is the typical model of its size class)WLWHD(24)ND6MO1 of 1 models have all five ratings · AHRI 218593170
Ducted, 2.5–3 tons52.2(50 is the typical model of its size class)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 21859317261.6(50 is the typical model of its size class)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593171
Ducted, 3.5–4.5 tons55.7(50 is the typical model of its size class)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 21859317369.1(50 is the typical model of its size class)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593173
Non-ducted, up to 1.5 tons61.4(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models qualify · AHRI 21859316352.7(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models have all five ratings · AHRI 218593163
Non-ducted, 2 tons67.5(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models qualify · AHRI 21859316467.6(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models have all five ratings · AHRI 218593164
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 21859316670.5(50 is the typical model of its size class)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593165
Non-ducted, 3.5–4.5 tons66.5(50 is the typical model of its size class)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 21859316767.7(50 is the typical model of its size class)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593167

All-around board, every manufacturer

Newest TRUENORTH certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TRUENORTH outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
WLWHD(60)ND6MOTRUENORTH4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2058%9.020.0CEE 25CEE 263218593180
WLWHD(42)ND6MOTRUENORTH3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8488%9.019.0CEE 25CEE 26Xcel3218593177
WLWHD(36)ND6MOTRUENORTH3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8494%9.019.0CEE 25CEE 26CEE AdvXcelDOE3218593176
WLWHD(30)ND6MOTRUENORTH2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8188%9.019.0CEE 25CEE 26Xcel3218593175
WLWHD(24)ND6MOTRUENORTH2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8090%9.019.0CEE 25CEE 26Xcel3218593174

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for TRUENORTH in this group.

Compare TRUENORTH

Manufacturers of a similar size, side by side.

TRUENORTH includes these brand names as listed in AHRI: TRUENORTH. Standards are checked against published thresholds; program rules beyond ratings are not checked.