Skip to content

TRUENORTH heat pump efficiency: 24 outdoor models compared

TRUENORTH has 24 heat pump outdoor models certified with this refrigerant group, in 80 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUENORTH makes. TRUENORTH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
24
AHRI certifications
80
Efficiency index
58%
Typical model vs same-size, same-type peers (30 models)
Meet CEE 2025
95.8%
23 models

How TRUENORTH compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TRUENORTH against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of TRUENORTH’s own modelsTRUENORTH is strongest on heating capacity at 5°F (its typical model beats 71% of comparable models) and weakest on COP at 5°F (50%).
  • TRUENORTH
  • Middle half of its models
  • Other ranked manufacturers
TRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile of TRUENORTH’s models
RatingBeats comparable modelsRankRaw median
Efficiency index30 models scored58%Not ranked—
COP at 5°F30 models scored50%Not ranked2.00
Capacity retention at 5°F30 models scored70%Not ranked90%
HSPF230 models scored55%Not ranked10.0
SEER230 models scored59%Not ranked18.9
EER230 models scored58%Not ranked11.8
Heating capacity at 5°F30 models scored71%Not ranked26,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TRUENORTH’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • TRUENORTH (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons357%57%31%58%
Ducted, 2 tons554%38%58%47%
Ducted, 2.5 to 3 tons559%42%61%69%
Ducted, 3.5 to 4.5 tons773%62%81%84%
Non-ducted, up to 1.5 tons440%42%29%36%
Non-ducted, 2 tons252%39%43%40%
Non-ducted, 2.5 to 3 tons268%86%60%50%
Non-ducted, 3.5 to 4.5 tons249%45%40%43%

Every TRUENORTH model in the market

TRUENORTH’s 30 models with a known size and duct type, over the shape of the whole catalog.
TRUENORTH models by size and ratingColoured: TRUENORTH · grey shapes: all 15,936 models · lines: catalog medians by size
  • TRUENORTH models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 30 truenorth models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

TRUENORTH in the cold

From NEEP’s cold-climate listings: 23 TRUENORTH models against all 6,343 listed models.
TRUENORTH capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical TRUENORTH model keeps 84% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • TRUENORTH (median, middle 50%)
Heating capacity, % of its 47°F maximum84%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
TRUENORTH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F23100%100%100%100%100%
TRUENORTH, 17°F2374%82%86%91%97%
TRUENORTH, 5°F2370%73%84%98%99%
TRUENORTH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F233.033.193.333.513.58
TRUENORTH, 17°F232.082.322.42.562.67
TRUENORTH, 5°F231.851.9722.092.1

Source: NEEP ccASHP list · as of

Top TRUENORTH models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 TRUENORTH cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1GUD60W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD60AH2/E-D(U)Also listed as WLUD60W2/NHE-D(U)4.5 tons53,000 Btu/h · Ducted100%2.1010.554,00018.2CEE 25CEE 26CEE AdvXcelDOEES CC7218853784Ducted, 3.5 to 4.5 tons85.1
2GUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD48AH2/E-D(U)Also listed as WLUD48W2/NHE-D(U)4 tons48,000 Btu/h · Ducted100%2.0010.048,00019.0CEE 25CEE 26XcelES CC2218853785Ducted, 3.5 to 4.5 tons78.9
3WLWHD(36)ND6MOTRUENORTH · M-Series3 tons36,000 Btu/h · Non-ducted100%2.1010.036,00021.0CEE 25CEE 26CEE AdvXcelDOEES CC3218593166Non-ducted, 2.5 to 3 tons77.8
4GUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)2 tons24,000 Btu/h · Ducted100%2.0010.025,00018.0CEE 25CEE 26XcelES CC2218853786Ducted, 2 tons76.3
5GUD36W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD36W2/NHE-D(U)2 tons24,000 Btu/h · Ducted96%2.0010.024,00018.0CEE 25CEE 26XcelES CC11218853789Ducted, 2.5 to 3 tons74.9

All-around best

Top 5 TRUENORTH models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1GUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD48AH2/E-D(U)Also listed as GUD60W2/NHE-D(U), WLUD48W2/NHE-D(U), WLUD60W2/NHE-D(U)4 tons48,000 Btu/h · Ducted100%2.0010.019.011.7CEE 25CEE 26XcelES CC2218853785Ducted, 3.5 to 4.5 tons80.078.981.278.9
2GUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler GUD48AH2/G-D(U)Also listed as WLUD60W2/NHG-D(U)4 tons48,000 Btu/h · Ducted75%2.189.520.011.7CEE 25CEE 26Xcel4218853788Ducted, 3.5 to 4.5 tons78.473.183.873.7
3WLWHD(30)ND6MOTRUENORTH · M-Series2.5 tons28,400 Btu/h · Non-ducted90%2.0710.021.013.6CEE 25CEE 26XcelES CC3218593165Non-ducted, 2.5 to 3 tons71.270.572.070.5
4WLWHD(24)ND6MOTRUENORTH · M-Series2 tons24,000 Btu/h · Non-ducted90%2.0010.021.013.3CEE 25CEE 26XcelES CC3218593164Non-ducted, 2 tons69.368.570.168.5
5GUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)2 tons24,000 Btu/h · Ducted100%2.0010.018.012.0CEE 25CEE 26XcelES CC2218853786Ducted, 2 tons68.676.361.076.3

Best model on each rating

TRUENORTH’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FWLWHD(36)ND6MO2.10Non-ducted, 2.5 to 3 tons87%218593166
Capacity retention at 5°FGUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)100%Ducted, 3.5 to 4.5 tons94%218853784
HSPF2GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)10.5Ducted, 3.5 to 4.5 tons91%218853784
SEER2GUD60W2/NHG-D(U)Also listed as WLUD60W2/NHG-D(U)20.0Ducted, 3.5 to 4.5 tons91%218853788
EER2WLWHD(42)ND6MO13.0Non-ducted, 3.5 to 4.5 tons95%218593167
Heating capacity at 5°FGUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U)54,000 Btu/hDucted, 3.5 to 4.5 tons98%218853784

All 24 TRUENORTH models in Explore

TRUENORTH size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TRUENORTH: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons63.5(50 is the typical model of its size class)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models qualify · AHRI 21885380864.6(50 is the typical model of its size class)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models have all five ratings · AHRI 218853808
Ducted, 2 tons76.3(50 is the typical model of its size class)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models qualify · AHRI 21885378668.6(50 is the typical model of its size class)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853786
Ducted, 2.5 to 3 tons52.0(50 is the typical model of its size class)WLWHD(36)ND6MO3 of 3 models qualify · AHRI 21859317261.6(50 is the typical model of its size class)WLWHD(30)ND6MO3 of 3 models have all five ratings · AHRI 218593171
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler GUD60AH2/E-D(U)Also listed as WLUD60W2/NHE-D(U)6 of 7 models qualify · AHRI 21885378480.0(50 is the typical model of its size class)GUD48W2/NHE-D(U)with ducted air handler GUD48AH2/E-D(U)Also listed as GUD60W2/NHE-D(U), WLUD48W2/NHE-D(U), WLUD60W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853785
Non-ducted, up to 1.5 tons63.2(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models qualify · AHRI 21859316355.2(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models have all five ratings · AHRI 218593163
Non-ducted, 2 tons68.5(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models qualify · AHRI 21859316469.3(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models have all five ratings · AHRI 218593164
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 21859316671.2(50 is the typical model of its size class)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593165
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 21859316767.8(50 is the typical model of its size class)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593167

All-around board, every manufacturer

Newest TRUENORTH certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TRUENORTH outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
WLUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD48AH2/G-D(U)4 tons48,000 Btu/h · Ducted2.00100%10.019.0CEE 25CEE 26XcelES CC2218853840
WLUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD24AH2/G-D(U)2 tons24,000 Btu/h · Ducted2.0096%10.018.0CEE 25CEE 26XcelES CC2218853839
WLUD60W2/NHE-D(U)TRUENORTHwith indoor coil WLCAC48H/NHA and furnace C105-M-V4 tons48,000 Btu/h · Ducted1.8083%8.515.2CEE 25CEE 26CEE AdvXcelDOEES CC7218853838
WLUD18W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD12AH2/E-D(U)1.5 tons17,000 Btu/h · Ducted2.00100%9.018.0CEE 25CEE 26XcelES CC1218853837
WLUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler WLCAC60H/NHA4.5 tons51,000 Btu/h · Ducted1.8067%8.516.0CEE 25CEE 26Xcel4218853836

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for TRUENORTH in this group.

Compare TRUENORTH

Manufacturers of a similar size, side by side.

TRUENORTH includes these brand names as listed in AHRI: TRUENORTH. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter