- Insights
- Manufacturers
- TRUENORTH
Both views use the same certified data. This device remembers your choice.
TRUENORTH heat pump efficiency: 24 outdoor models compared
TRUENORTH has 24 heat pump outdoor models certified with this refrigerant group, in 80 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUENORTH makes. TRUENORTH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 24
- AHRI certifications
- 80
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (30 models)
- Meet CEE 2025
- 95.8%
- 23 models
How TRUENORTH compares with comparable models
- TRUENORTH
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index30 models scored | 58% | Not ranked | — |
| COP at 5°F30 models scored | 50% | Not ranked | 2.00 |
| Capacity retention at 5°F30 models scored | 70% | Not ranked | 90% |
| HSPF230 models scored | 55% | Not ranked | 10.0 |
| SEER230 models scored | 59% | Not ranked | 18.9 |
| EER230 models scored | 58% | Not ranked | 11.8 |
| Heating capacity at 5°F30 models scored | 71% | Not ranked | 26,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 95.8% | 23 |
| CEE 2026 Tier 1 (Split ASHP) | 95.8% | 23 |
| CEE Advanced Tier (Split ASHP) | 12.5% | 3 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 95.8% | 23 |
| DOE Cold Climate Heat Pump Challenge | 12.5% | 3 |
| ENERGY STAR Cold Climate | 79.2% | 19 |
Sizes and duct types offered
- TRUENORTH (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 57% | 57% | 31% | 58% |
| Ducted, 2 tons | 5 | 54% | 38% | 58% | 47% |
| Ducted, 2.5 to 3 tons | 5 | 59% | 42% | 61% | 69% |
| Ducted, 3.5 to 4.5 tons | 7 | 73% | 62% | 81% | 84% |
| Non-ducted, up to 1.5 tons | 4 | 40% | 42% | 29% | 36% |
| Non-ducted, 2 tons | 2 | 52% | 39% | 43% | 40% |
| Non-ducted, 2.5 to 3 tons | 2 | 68% | 86% | 60% | 50% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 49% | 45% | 40% | 43% |
Every TRUENORTH model in the market
- TRUENORTH models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
TRUENORTH in the cold
- All listed models (median, middle 50% and 80%)
- TRUENORTH (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 23 | 100% | 100% | 100% | 100% | 100% |
| TRUENORTH, 17°F | 23 | 74% | 82% | 86% | 91% | 97% |
| TRUENORTH, 5°F | 23 | 70% | 73% | 84% | 98% | 99% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 23 | 3.03 | 3.19 | 3.33 | 3.51 | 3.58 |
| TRUENORTH, 17°F | 23 | 2.08 | 2.32 | 2.4 | 2.56 | 2.67 |
| TRUENORTH, 5°F | 23 | 1.85 | 1.97 | 2 | 2.09 | 2.1 |
Source: NEEP ccASHP list · as of
Top TRUENORTH models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1GUD60W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD60AH2/E-D(U)Also listed as WLUD60W2/NHE-D(U) | 4.5 tons53,000 Btu/h · Ducted | 100% | 2.10 | 10.5 | 54,000 | 18.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218853784 | Ducted, 3.5 to 4.5 tons | 85.1 |
| 2GUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD48AH2/E-D(U)Also listed as WLUD48W2/NHE-D(U) | 4 tons48,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 48,000 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 218853785 | Ducted, 3.5 to 4.5 tons | 78.9 |
| 3WLWHD(36)ND6MOTRUENORTH · M-Series | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.10 | 10.0 | 36,000 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218593166 | Non-ducted, 2.5 to 3 tons | 77.8 |
| 4GUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U) | 2 tons24,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 25,000 | 18.0 | CEE 25CEE 26XcelES CC | 2 | 218853786 | Ducted, 2 tons | 76.3 |
| 5GUD36W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD36W2/NHE-D(U) | 2 tons24,000 Btu/h · Ducted | 96% | 2.00 | 10.0 | 24,000 | 18.0 | CEE 25CEE 26XcelES CC | 11 | 218853789 | Ducted, 2.5 to 3 tons | 74.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1GUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD48AH2/E-D(U)Also listed as GUD60W2/NHE-D(U), WLUD48W2/NHE-D(U), WLUD60W2/NHE-D(U) | 4 tons48,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 19.0 | 11.7 | CEE 25CEE 26XcelES CC | 2 | 218853785 | Ducted, 3.5 to 4.5 tons | 80.0 | 78.9 | 81.2 | 78.9 |
| 2GUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler GUD48AH2/G-D(U)Also listed as WLUD60W2/NHG-D(U) | 4 tons48,000 Btu/h · Ducted | 75% | 2.18 | 9.5 | 20.0 | 11.7 | CEE 25CEE 26Xcel | 4 | 218853788 | Ducted, 3.5 to 4.5 tons | 78.4 | 73.1 | 83.8 | 73.7 |
| 3WLWHD(30)ND6MOTRUENORTH · M-Series | 2.5 tons28,400 Btu/h · Non-ducted | 90% | 2.07 | 10.0 | 21.0 | 13.6 | CEE 25CEE 26XcelES CC | 3 | 218593165 | Non-ducted, 2.5 to 3 tons | 71.2 | 70.5 | 72.0 | 70.5 |
| 4WLWHD(24)ND6MOTRUENORTH · M-Series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 21.0 | 13.3 | CEE 25CEE 26XcelES CC | 3 | 218593164 | Non-ducted, 2 tons | 69.3 | 68.5 | 70.1 | 68.5 |
| 5GUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U) | 2 tons24,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 18.0 | 12.0 | CEE 25CEE 26XcelES CC | 2 | 218853786 | Ducted, 2 tons | 68.6 | 76.3 | 61.0 | 76.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WLWHD(36)ND6MO | 2.10 | Non-ducted, 2.5 to 3 tons | 87% | 218593166 |
| Capacity retention at 5°F | GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U) | 100% | Ducted, 3.5 to 4.5 tons | 94% | 218853784 |
| HSPF2 | GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U) | 10.5 | Ducted, 3.5 to 4.5 tons | 91% | 218853784 |
| SEER2 | GUD60W2/NHG-D(U)Also listed as WLUD60W2/NHG-D(U) | 20.0 | Ducted, 3.5 to 4.5 tons | 91% | 218853788 |
| EER2 | WLWHD(42)ND6MO | 13.0 | Non-ducted, 3.5 to 4.5 tons | 95% | 218593167 |
| Heating capacity at 5°F | GUD60W2/NHE-D(U)Also listed as WLUD60W2/NHE-D(U) | 54,000 Btu/h | Ducted, 3.5 to 4.5 tons | 98% | 218853784 |
TRUENORTH size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.5(50 is the typical model of its size class)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models qualify · AHRI 218853808 | 64.6(50 is the typical model of its size class)GUD18W2/NHE-D(U)with ducted air handler GUD12AH2/E-D(U)Also listed as WLUD18W2/NHE-D(U)3 of 3 models have all five ratings · AHRI 218853808 |
| Ducted, 2 tons | 76.3(50 is the typical model of its size class)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models qualify · AHRI 218853786 | 68.6(50 is the typical model of its size class)GUD24W2/NHE-D(U)with ducted air handler GUD24AH2/E-D(U)Also listed as WLUD24W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853786 |
| Ducted, 2.5 to 3 tons | 52.0(50 is the typical model of its size class)WLWHD(36)ND6MO3 of 3 models qualify · AHRI 218593172 | 61.6(50 is the typical model of its size class)WLWHD(30)ND6MO3 of 3 models have all five ratings · AHRI 218593171 |
| Ducted, 3.5 to 4.5 tons | 85.1(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler GUD60AH2/E-D(U)Also listed as WLUD60W2/NHE-D(U)6 of 7 models qualify · AHRI 218853784 | 80.0(50 is the typical model of its size class)GUD48W2/NHE-D(U)with ducted air handler GUD48AH2/E-D(U)Also listed as GUD60W2/NHE-D(U), WLUD48W2/NHE-D(U), WLUD60W2/NHE-D(U)7 of 7 models have all five ratings · AHRI 218853785 |
| Non-ducted, up to 1.5 tons | 63.2(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models qualify · AHRI 218593163 | 55.2(50 is the typical model of its size class)WLWHD(18)ND6MO4 of 4 models have all five ratings · AHRI 218593163 |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models qualify · AHRI 218593164 | 69.3(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models have all five ratings · AHRI 218593164 |
| Non-ducted, 2.5 to 3 tons | 77.8(50 is the typical model of its size class)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 218593166 | 71.2(50 is the typical model of its size class)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593165 |
| Non-ducted, 3.5 to 4.5 tons | 67.0(50 is the typical model of its size class)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 218593167 | 67.8(50 is the typical model of its size class)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593167 |
Newest TRUENORTH certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WLUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD48AH2/G-D(U) | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 218853840 |
| WLUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD24AH2/G-D(U) | 2 tons24,000 Btu/h · Ducted | 2.00 | 96% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 2 | 218853839 |
| WLUD60W2/NHE-D(U)TRUENORTHwith indoor coil WLCAC48H/NHA and furnace C105-M-V | 4 tons48,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 15.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218853838 |
| WLUD18W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD12AH2/E-D(U) | 1.5 tons17,000 Btu/h · Ducted | 2.00 | 100% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218853837 |
| WLUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler WLCAC60H/NHA | 4.5 tons51,000 Btu/h · Ducted | 1.80 | 67% | 8.5 | 16.0 | CEE 25CEE 26Xcel | 4 | 218853836 |
Compare TRUENORTH
TRUENORTH includes these brand names as listed in AHRI: TRUENORTH. Standards are checked against published thresholds; program rules beyond ratings are not checked.