Skip to content

NG Trade heat pump efficiency: 36 outdoor models compared

NG Trade has 36 heat pump outdoor models certified with this refrigerant group, in 49 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes NG Trade makes. NG Trade has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
36
AHRI certifications
49
Efficiency index
55%
Typical model vs same-size, same-type peers (39 models)
Meet CEE 2025
75%
27 models

How NG Trade compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
NG Trade against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of NG Trade’s own modelsNG Trade is strongest on COP at 5°F (its typical model beats 63% of comparable models) and weakest on capacity retention at 5°F (39%).
  • NG Trade
  • Middle half of its models
  • Other ranked manufacturers
NG Trade

Source: AHRI Directory, NEEP · as of

Average peer percentile of NG Trade’s models
RatingBeats comparable modelsRankRaw median
Efficiency index39 models scored55%Not ranked—
COP at 5°F40 models scored63%Not ranked2.01
Capacity retention at 5°F39 models scored39%Not ranked70%
HSPF244 models scored52%Not ranked9.2
SEER244 models scored58%Not ranked20.6
EER244 models scored46%Not ranked11.6
Heating capacity at 5°F40 models scored47%Not ranked14,950 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
NG Trade’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • NG Trade (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons361%67%60%74%
Ducted, 2 tons258%42%67%78%
Ducted, 2.5 to 3 tons563%65%71%77%
Ducted, 3.5 to 4.5 tons355%41%70%64%
Ducted, 5 tons and up163%67%82%89%
Non-ducted, up to 1.5 tons1754%70%47%51%
Non-ducted, 2 tons554%64%44%50%
Non-ducted, 2.5 to 3 tons652%59%39%54%
Non-ducted, 3.5 to 4.5 tons151%82%40%62%
Non-ducted, 5 tons and up127%41%18%16%

Every NG Trade model in the market

NG Trade’s 44 models with a known size and duct type, over the shape of the whole catalog.
NG Trade models by size and ratingColoured: NG Trade · grey shapes: all 15,936 models · lines: catalog medians by size
  • NG Trade models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 44 ng trade models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

NG Trade in the cold

From NEEP’s cold-climate listings: 27 NG Trade models against all 6,343 listed models.
NG Trade capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical NG Trade model keeps 63% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • NG Trade (median, middle 50%)
Heating capacity, % of its 47°F maximum63%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
NG Trade: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
NG Trade, 47°F27100%100%100%100%100%
NG Trade, 17°F2766%67%71%73%78%
NG Trade, 5°F2756%59%63%66%68%
NG Trade: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
NG Trade, 47°F272.893.083.283.543.72
NG Trade, 17°F272.162.222.32.52.62
NG Trade, 5°F271.851.9722.112.31

Source: NEEP ccASHP list · as of

Top NG Trade models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 NG Trade cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1OMSTAR091ENG Trade · OMS Serieswith ductless indoor unit IMSTAR091E1 ton9,000 Btu/h · Non-ducted82%2.3313.08,20024.6CEE 25CEE 26XcelES CC1216732475Non-ducted, up to 1.5 tons86.8
2MOBMH480DNG Trade · MOB Series4 tons45,000 Btu/h · Ducted81%2.1010.638,00020.4CEE 25CEE 26XcelES CC3216598398Ducted, 3.5 to 4.5 tons78.1
3OMSTAR121ENG Trade · OMS Serieswith ductless indoor unit IMSTAR121E1 ton12,000 Btu/h · Non-ducted72%2.3611.58,60023.1CEE 25CEE 26XcelES CC1216732476Non-ducted, up to 1.5 tons74.3
4OMSTAR181ENG Trade · OMS Serieswith ductless indoor unit IMSTAR181E1.5 tons18,000 Btu/h · Non-ducted72%2.3511.113,00024.0CEE 25CEE 26XcelES CC1216732477Non-ducted, up to 1.5 tons74.3
5MOSA32301NG TRADE · Multi-spilt series2.5 tons30,000 Btu/h · Ducted77%2.109.523,00020.0CEE 25CEE 26XcelES CC2217501893Ducted, 2.5 to 3 tons73.7

All-around best

Top 5 NG Trade models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1OMSTAR091ENG Trade · OMS Serieswith ductless indoor unit IMSTAR091E1 ton9,000 Btu/h · Non-ducted82%2.3313.024.614.7CEE 25CEE 26XcelES CC1216732475Non-ducted, up to 1.5 tons87.786.888.686.8
2MOBMH480DNG Trade · MOB Series4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26XcelES CC3216598398Ducted, 3.5 to 4.5 tons85.378.192.678.1
3MOSA32301NG TRADE · Multi-spilt series2.5 tons30,000 Btu/h · Ducted77%2.109.520.012.0CEE 25CEE 26XcelES CC2217501893Ducted, 2.5 to 3 tons80.873.788.073.7
4OMSTAR181ENG Trade · OMS Serieswith ductless indoor unit IMSTAR181E1.5 tons18,000 Btu/h · Non-ducted72%2.3511.124.013.5CEE 25CEE 26XcelES CC1216732477Non-ducted, up to 1.5 tons78.074.381.874.3
5OMSTAR241ENG Trade · OMS Serieswith ductless indoor unit IMSTAR241E2 tons24,000 Btu/h · Non-ducted71%2.1510.023.513.0CEE 25CEE 26XcelES CC1216732478Non-ducted, 2 tons75.965.486.565.4

Best model on each rating

NG Trade’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FOMSTAR121E2.36Non-ducted, up to 1.5 tons95%216732476
Capacity retention at 5°FMOBMH600D67%Ducted, 5 tons and up70%216598401
HSPF2OMSTAR091E13.0Non-ducted, up to 1.5 tons96%216732475
SEER2MOBMH480D20.4Ducted, 3.5 to 4.5 tons96%216598398
EER2OMSTAR091E14.7Non-ducted, up to 1.5 tons89%216732475
Heating capacity at 5°FMOSA3218114,500 Btu/hNon-ducted, up to 1.5 tons86%218029189

All 36 NG Trade models in Explore

NG Trade size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
NG Trade: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons73.2(50 is the typical model of its size class)MOBMH180D2 of 3 models qualify · AHRI 21659838974.8(50 is the typical model of its size class)MOBMH180D3 of 3 models have all five ratings · AHRI 216598389
Ducted, 2 tons59.6(50 is the typical model of its size class)EZCENO24Kwith ducted air handler EZCENI24K2 of 2 models qualify · AHRI 21676302264.6(50 is the typical model of its size class)MOBMH270D2 of 2 models have all five ratings · AHRI 216598392
Ducted, 2.5 to 3 tons73.7(50 is the typical model of its size class)MOSA323014 of 5 models qualify · AHRI 21750189380.8(50 is the typical model of its size class)MOSA323015 of 5 models have all five ratings · AHRI 217501893
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)MOBMH480D3 of 3 models qualify · AHRI 21659839885.3(50 is the typical model of its size class)MOBMH480D3 of 3 models have all five ratings · AHRI 216598398
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)63.2(50 is the typical model of its size class)MOBMH600D1 of 1 models have all five ratings · AHRI 216598401
Non-ducted, up to 1.5 tons86.8(50 is the typical model of its size class)OMSTAR091Ewith ductless indoor unit IMSTAR091E7 of 17 models qualify · AHRI 21673247587.7(50 is the typical model of its size class)OMSTAR091Ewith ductless indoor unit IMSTAR091E14 of 17 models have all five ratings · AHRI 216732475
Non-ducted, 2 tons65.4(50 is the typical model of its size class)OMSTAR241Ewith ductless indoor unit IMSTAR241E3 of 5 models qualify · AHRI 21673247875.9(50 is the typical model of its size class)OMSTAR241Ewith ductless indoor unit IMSTAR241E4 of 5 models have all five ratings · AHRI 216732478
Non-ducted, 2.5 to 3 tons58.3(50 is the typical model of its size class)MOSA323013 of 6 models qualify · AHRI 21802919067.4(50 is the typical model of its size class)MOSA323015 of 6 models have all five ratings · AHRI 218029190
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class)MOBMH480D1 of 1 models qualify · AHRI 21659839953.1(50 is the typical model of its size class)MOBMH480D1 of 1 models have all five ratings · AHRI 216598399
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)32.9(50 is the typical model of its size class)MOBMH600D1 of 1 models have all five ratings · AHRI 216598400

All-around board, every manufacturer

Newest NG Trade certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified NG Trade outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
OJST32241NG TRADEwith ductless indoor unit IJST322412 tons24,000 Btu/h · Non-ducted——8.017.0None1218690285
OJST32181NG TRADEwith ductless indoor unit IJST321811.5 tons18,000 Btu/h · Non-ducted——8.017.0None1218690284
OJST32121NG TRADEwith ductless indoor unit IJST321211 ton12,000 Btu/h · Non-ducted——8.017.0None1218690283
OJST32120NG TRADEwith ductless indoor unit IJST321201 ton12,000 Btu/h · Non-ducted——8.017.0None1218690282
MOSA32361NG TRADE · Multi-spilt series3 tons36,000 Btu/h · Ducted and non-ducted2.0071%10.023.0CEE 25CEE 26XcelES CC2218029191

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare NG Trade

Manufacturers of a similar size, side by side.

NG Trade includes these brand names as listed in AHRI: NG Trade. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter