- Insights
- Manufacturers
- Proair
Both views use the same certified data. This device remembers your choice.
Proair heat pump efficiency: 30 outdoor models compared
Proair has 30 heat pump outdoor models certified with this refrigerant group, in 70 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Proair makes. Proair has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 30
- AHRI certifications
- 70
- Efficiency index
- 53%
- Typical model vs same-size, same-type peers (40 models)
- Meet CEE 2025
- 70%
- 21 models
How Proair compares with comparable models
- Proair
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index40 models scored | 53% | Not ranked | — |
| COP at 5°F40 models scored | 50% | Not ranked | 1.99 |
| Capacity retention at 5°F40 models scored | 56% | Not ranked | 75% |
| HSPF240 models scored | 60% | Not ranked | 9.2 |
| SEER240 models scored | 56% | Not ranked | 19.2 |
| EER240 models scored | 46% | Not ranked | 10.9 |
| Heating capacity at 5°F40 models scored | 62% | Not ranked | 22,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 70% | 21 |
| CEE 2026 Tier 1 (Split ASHP) | 70% | 21 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66.7% | 20 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 63.3% | 19 |
Sizes and duct types offered
- Proair (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 4 | 62% | 65% | 63% | 68% |
| Ducted, 2 tons | 3 | 46% | 31% | 62% | 56% |
| Ducted, 2.5 to 3 tons | 7 | 58% | 46% | 73% | 59% |
| Ducted, 3.5 to 4.5 tons | 7 | 59% | 44% | 76% | 61% |
| Ducted, 5 tons and up | 1 | 63% | 67% | 82% | 89% |
| Non-ducted, up to 1.5 tons | 7 | 46% | 54% | 43% | 51% |
| Non-ducted, 2 tons | 2 | 45% | 63% | 36% | 50% |
| Non-ducted, 2.5 to 3 tons | 5 | 48% | 41% | 51% | 49% |
| Non-ducted, 3.5 to 4.5 tons | 3 | 57% | 62% | 59% | 51% |
| Non-ducted, 5 tons and up | 1 | 27% | 41% | 18% | 16% |
Every Proair model in the market
- Proair models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Proair in the cold
- All listed models (median, middle 50% and 80%)
- Proair (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Proair, 47°F | 30 | 100% | 100% | 100% | 100% | 100% |
| Proair, 17°F | 30 | 66% | 71% | 73% | 81% | 84% |
| Proair, 5°F | 30 | 57% | 63% | 66% | 78% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Proair, 47°F | 30 | 2.8 | 2.97 | 3.1 | 3.28 | 3.54 |
| Proair, 17°F | 30 | 2 | 2.18 | 2.25 | 2.4 | 2.65 |
| Proair, 5°F | 30 | 1.8 | 1.85 | 1.99 | 2 | 2.1 |
Source: NEEP ccASHP list · as of
Top Proair models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PMUL-H5P-36HP-MProair · PMUL Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26XcelES CC | 3 | 217500248 | Ducted, 2.5 to 3 tons | 82.7 |
| 2PMUL-H6P-48HP-MProair · PMUL Series | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 48,000 | 20.4 | CEE 25CEE 26XcelES CC | 3 | 217500251 | Ducted, 3.5 to 4.5 tons | 82.6 |
| 3PMUL-H6P-60HP-MProair · PMUL Series | 4.5 tons53,000 Btu/h · Ducted | 87% | 2.10 | 10.7 | 48,000 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217500254 | Ducted, 3.5 to 4.5 tons | 81.2 |
| 4PMUL-A6P-48HP-MProair · PMUL Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 38,000 | 20.4 | CEE 25CEE 26Xcel | 3 | 217500236 | Ducted, 3.5 to 4.5 tons | 78.1 |
| 5P30-18CENHP-R454Proair · P30 Serieswith ducted air handler PAC-24B18T-INT | 1.5 tons18,000 Btu/h · Ducted | 95% | 2.06 | 9.5 | 18,000 | 16.1 | CEE 25CEE 26XcelES CC | 1 | 217500210 | Ducted, up to 1.5 tons | 73.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PMUL-A6P-48HP-MProair · PMUL Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 217500236 | Ducted, 3.5 to 4.5 tons | 85.3 | 78.1 | 92.6 | 78.1 |
| 2PMUL-H6P-48HP-MProair · PMUL Series | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 217500251 | Ducted, 3.5 to 4.5 tons | 84.3 | 82.6 | 86.0 | 82.6 |
| 3PMUL-H5P-36HP-MProair · PMUL Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217500248 | Ducted, 2.5 to 3 tons | 83.9 | 82.7 | 85.1 | 82.7 |
| 4PMUL-H6P-60HP-MProair · PMUL Series | 4.5 tons53,000 Btu/h · Ducted | 87% | 2.10 | 10.7 | 20.0 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 217500254 | Ducted, 3.5 to 4.5 tons | 82.5 | 81.2 | 83.8 | 81.2 |
| 5PMUL-H3P-18HP-MProair · PMUL Series | 1.5 tons19,000 Btu/h · Ducted | 90% | 2.00 | 10.0 | 20.0 | 13.0 | CEE 25CEE 26XcelES CC | 3 | 217500242 | Ducted, up to 1.5 tons | 77.9 | 71.3 | 84.6 | 71.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | PMUL-A3P-18HP-M | 2.25 | Non-ducted, up to 1.5 tons | 90% | 217500228 |
| Capacity retention at 5°F | P30-30CENHP-R454 | 107% | Ducted, 2.5 to 3 tons | 97% | 217500212 |
| HSPF2 | PMUL-H6P-48HP-M | 11.0 | Ducted, 3.5 to 4.5 tons | 99% | 217500251 |
| SEER2 | PMUL-A6P-48HP-M | 20.4 | Ducted, 3.5 to 4.5 tons | 96% | 217500236 |
| EER2 | PMUL-H3P-18HP-M | 13.0 | Ducted, up to 1.5 tons | 85% | 217500242 |
| Heating capacity at 5°F | PMUL-H5P-36HP-M | 37,400 Btu/h | Non-ducted, 2.5 to 3 tons | 95% | 217500249 |
Proair size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.6(50 is the typical model of its size class)P30-18CENHP-R454with ducted air handler PAC-24B18T-INT3 of 4 models qualify · AHRI 217500210 | 77.9(50 is the typical model of its size class)PMUL-H3P-18HP-M4 of 4 models have all five ratings · AHRI 217500242 |
| Ducted, 2 tons | 55.0(50 is the typical model of its size class)P30-24CENHP-R454with ducted air handler PAC-24B18T-INT3 of 3 models qualify · AHRI 217500211 | 64.6(50 is the typical model of its size class)PMUL-A4P-27HP-M3 of 3 models have all five ratings · AHRI 217500230 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class)PMUL-H5P-36HP-M6 of 7 models qualify · AHRI 217500248 | 83.9(50 is the typical model of its size class)PMUL-H5P-36HP-M7 of 7 models have all five ratings · AHRI 217500248 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)PMUL-H6P-48HP-M7 of 7 models qualify · AHRI 217500251 | 85.3(50 is the typical model of its size class)PMUL-A6P-48HP-M7 of 7 models have all five ratings · AHRI 217500236 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 63.2(50 is the typical model of its size class)PMUL-A3P-60HP-M1 of 1 models have all five ratings · AHRI 217500239 |
| Non-ducted, up to 1.5 tons | 68.8(50 is the typical model of its size class)PMUL-H3P-18HP-M4 of 7 models qualify · AHRI 217500241 | 64.9(50 is the typical model of its size class)PMUL-H3P-18HP-M7 of 7 models have all five ratings · AHRI 217500241 |
| Non-ducted, 2 tons | 47.2(50 is the typical model of its size class)POX21-24HFN10-Mwith ductless indoor unit PSAG-24HWM-M2 of 2 models qualify · AHRI 217500223 | 59.0(50 is the typical model of its size class)PMUL-A4P-27HP-M2 of 2 models have all five ratings · AHRI 217500229 |
| Non-ducted, 2.5 to 3 tons | 72.8(50 is the typical model of its size class)PMUL-H5P-36HP-M3 of 5 models qualify · AHRI 217500249 | 67.0(50 is the typical model of its size class)PMUL-H5P-36HP-M5 of 5 models have all five ratings · AHRI 217500247 |
| Non-ducted, 3.5 to 4.5 tons | 70.3(50 is the typical model of its size class)PMUL-H6P-60HP-M3 of 3 models qualify · AHRI 217500255 | 62.6(50 is the typical model of its size class)PMUL-H6P-60HP-M3 of 3 models have all five ratings · AHRI 217500253 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 32.9(50 is the typical model of its size class)PMUL-A3P-60HP-M1 of 1 models have all five ratings · AHRI 217500238 |
Newest Proair certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| P25-48CENHP-R454Proairwith indoor coil PAC-60C28T-INT and furnace S9V2B080U4VS | 4 tons45,000 Btu/h · Ducted | 1.80 | 87% | 8.0 | 16.6 | XcelES CC | 2 | 217607744 |
| P25-36CENHP-R454Proairwith indoor coil PAC-36B24T-INT and furnace S9V2B080U4VS | 3 tons36,000 Btu/h · Ducted | 1.80 | 69% | 8.2 | 14.4 | None | 6 | 217607743 |
| P30-48CENHP-R454Proair · P30 Serieswith indoor coil PAC-60D28T-INT and furnace S9V2B080U4VS | 4 tons46,000 Btu/h · Ducted | 1.80 | 87% | 8.5 | 16.6 | CEE 25CEE 26XcelES CC | 2 | 217607739 |
| P30-36CENHP-R454Proair · P30 Serieswith indoor coil PAC-36B24T-INT and furnace S9V2B080U4VS | 3 tons36,000 Btu/h · Ducted | 1.80 | 89% | 9.2 | 15.5 | XcelES CC | 6 | 217607738 |
| P30-24CENHP-R454Proair · P30 Serieswith indoor coil PAC-24B18T-INT and furnace S9V2B060D3VS | 2 tons24,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 17.2 | CEE 25CEE 26XcelES CC | 4 | 217607734 |
Compare Proair
Proair includes these brand names as listed in AHRI: Proair. Standards are checked against published thresholds; program rules beyond ratings are not checked.