Both views use the same certified data. This device remembers your choice.
Proair vs UTL heat pumps
Measured against models of the same size and duct type, UTL scores higher on 4 of the 6 ratings. Proair has 30 outdoor models, UTL has 30 outdoor models. Proair and UTL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Proair
- UTL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Proair | UTL |
|---|---|---|
| Efficiency index | 53%median — | 64%median — |
| COP at 5°F | 50%median 1.99 | 80%median 2.20 |
| Capacity retention at 5°F | 56%median 75% | 58%median 74% |
| HSPF2 | 60%median 9.2 | 75%median 9.4 |
| SEER2 | 56%median 19.2 | 70%median 18.3 |
| EER2 | 46% (higher)median 10.9 | 44% (higher)median 11.0 |
| Heating capacity at 5°F | 62% (higher)median 22,500 Btu/h | 59% (higher)median 25,800 Btu/h |
| Outdoor models | 30 | 30 |
| AHRI certifications | 70 | 38 |
Share of models meeting each standard
| Standard | Proair | UTL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 70%21 models | 86.7%26 models |
| CEE 2026 Tier 1 (Split ASHP) | 70%21 models | 86.7%26 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 10%3 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66.7%20 models | 83.3%25 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 10%3 models |
| ENERGY STAR Cold Climate | 63.3%19 models | 100%30 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Proair
- UTL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Proair | UTL |
|---|---|---|
| Ducted, up to 1.5 tons | 4 · index 62% | 1 · index 52% |
| Ducted, 2 tons | 3 · index 46% | 7 · index 74% |
| Ducted, 2.5 to 3 tons | 7 · index 58% | 9 · index 62% |
| Ducted, 3.5 to 4.5 tons | 7 · index 59% | 13 · index 61% |
| Ducted, 5 tons and up | 1 · index 63% | None |
| Non-ducted, up to 1.5 tons | 7 · index 46% | None |
| Non-ducted, 2 tons | 2 · index 45% | None |
| Non-ducted, 2.5 to 3 tons | 5 · index 48% | None |
| Non-ducted, 3.5 to 4.5 tons | 3 · index 57% | None |
| Non-ducted, 5 tons and up | 1 · index 27% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ProairCold-climate score, best model | UTLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.4(50 is the typical model of its size class) (higher)P30-18CENHP-R454with ducted air handler PAC-24B18T-INT3 of 4 models qualify · AHRI 217500210 | 52.2(50 is the typical model of its size class)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models qualify · AHRI 218721137 |
| Ducted, 2 tons | 54.9(50 is the typical model of its size class)P30-24CENHP-R454with ducted air handler PAC-24B18T-INT3 of 3 models qualify · AHRI 217500211 | 89.4(50 is the typical model of its size class) (higher)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN27 of 7 models qualify · AHRI 218472797 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class) (higher)PMUL-H5P-36HP-M6 of 7 models qualify · AHRI 217500248 | 77.9(50 is the typical model of its size class)UCHA-36HDCTRN2with ducted air handler UCHA-36HDCALN29 of 9 models qualify · AHRI 218472798 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class) (higher)PMUL-H6P-48HP-M7 of 7 models qualify · AHRI 217500251 | 79.8(50 is the typical model of its size class)UCHA-48HDCTRN2with ducted air handler UCHA-48HDCALN213 of 13 models qualify · AHRI 218472800 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 68.9(50 is the typical model of its size class)PMUL-H3P-18HP-M4 of 7 models qualify · AHRI 217500241 | No models in this size class |
| Non-ducted, 2 tons | 47.2(50 is the typical model of its size class)POX21-24HFN10-Mwith ductless indoor unit PSAG-24HWM-M2 of 2 models qualify · AHRI 217500223 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 72.8(50 is the typical model of its size class)PMUL-H5P-36HP-M3 of 5 models qualify · AHRI 217500249 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 70.3(50 is the typical model of its size class)PMUL-H6P-60HP-M3 of 3 models qualify · AHRI 217500255 | No models in this size class |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | ProairAll-around score, best model | UTLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 77.8(50 is the typical model of its size class) (higher)PMUL-H3P-18HP-M4 of 4 models have all five ratings · AHRI 217500242 | 52.3(50 is the typical model of its size class)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models have all five ratings · AHRI 218721137 |
| Ducted, 2 tons | 64.6(50 is the typical model of its size class)PMUL-A4P-27HP-M3 of 3 models have all five ratings · AHRI 217500230 | 85.0(50 is the typical model of its size class) (higher)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN27 of 7 models have all five ratings · AHRI 218472797 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)PMUL-H5P-36HP-M7 of 7 models have all five ratings · AHRI 217500248 | 66.2(50 is the typical model of its size class)UCHA-36HDCT(O)with ducted air handler UCHA-36HDCT(I)Also listed as UCHA-36HDCT, UCHA-36HDCTN29 of 9 models have all five ratings · AHRI 214771549 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)PMUL-A6P-48HP-M7 of 7 models have all five ratings · AHRI 217500236 | 68.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDCAlso listed as UCHA-48HDCT, UCHA-48HDCTN213 of 13 models have all five ratings · AHRI 217014849 |
| Ducted, 5 tons and up | 63.2(50 is the typical model of its size class)PMUL-A3P-60HP-M1 of 1 models have all five ratings · AHRI 217500239 | No models in this size class |
| Non-ducted, up to 1.5 tons | 64.9(50 is the typical model of its size class)PMUL-H3P-18HP-M7 of 7 models have all five ratings · AHRI 217500241 | No models in this size class |
| Non-ducted, 2 tons | 59.0(50 is the typical model of its size class)PMUL-A4P-27HP-M2 of 2 models have all five ratings · AHRI 217500229 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 67.0(50 is the typical model of its size class)PMUL-H5P-36HP-M5 of 5 models have all five ratings · AHRI 217500247 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 62.6(50 is the typical model of its size class)PMUL-H6P-60HP-M3 of 3 models have all five ratings · AHRI 217500253 | No models in this size class |
| Non-ducted, 5 tons and up | 32.9(50 is the typical model of its size class)PMUL-A3P-60HP-M1 of 1 models have all five ratings · AHRI 217500238 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Proair | UTL |
|---|---|---|
| COP at 5°F | beats 90% · 2.25PMUL-A3P-18HP-MNon-ducted, up to 1.5 tons | beats 89% · 2.30UCHA-36HDCTRN2Ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 97% · 107%P30-30CENHP-R454Ducted, 2.5 to 3 tons | beats 92% · 100%UCHA-24HDCSN4Also listed as UCHA-24HDCSN2Ducted, 2 tons |
| HSPF2 | beats 99% · 11.0PMUL-H6P-48HP-MDucted, 3.5 to 4.5 tons | beats 91% · 10.5UCHA-48HDCTRN2Ducted, 3.5 to 4.5 tons |
| SEER2 | beats 96% · 20.4PMUL-A6P-48HP-MDucted, 3.5 to 4.5 tons | beats 86% · 20.0UCHA-24HDCTAlso listed as UCHA-24HDCT, UCHA-24HDCTN2Ducted, 2 tons |
| EER2 | beats 85% · 13.0PMUL-H3P-18HP-MDucted, up to 1.5 tons | beats 98% · 14.0UCHA-24HDCTAlso listed as UCHA-24HDCT, UCHA-24HDCTN2Ducted, 2 tons |
| Heating capacity at 5°F | beats 95% · 37,400 Btu/hPMUL-H5P-36HP-MNon-ducted, 2.5 to 3 tons | beats 89% · 24,000 Btu/hUCHA-24HDCSN4Also listed as UCHA-24HDCSN2Ducted, 2 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Proair (median, middle 50%)
- UTL (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Proair, 47°F | 30 | 100% | 100% | 100% | 100% | 100% |
| Proair, 17°F | 30 | 66% | 71% | 73% | 81% | 84% |
| Proair, 5°F | 30 | 57% | 63% | 66% | 78% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Proair, 47°F | 30 | 2.8 | 2.97 | 3.1 | 3.28 | 3.54 |
| Proair, 17°F | 30 | 2 | 2.18 | 2.25 | 2.4 | 2.65 |
| Proair, 5°F | 30 | 1.8 | 1.85 | 1.99 | 2 | 2.1 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| UTL, 47°F | 16 | 100% | 100% | 100% | 100% | 100% |
| UTL, 17°F | 16 | 83% | 84% | 95% | 100% | 100% |
| UTL, 5°F | 16 | 73% | 74% | 75% | 77% | 100% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| UTL, 47°F | 16 | 3.5 | 3.5 | 3.8 | 3.8 | 3.8 |
| UTL, 17°F | 16 | 2.1 | 2.24 | 2.4 | 2.42 | 2.58 |
| UTL, 5°F | 16 | 2.15 | 2.2 | 2.2 | 2.21 | 2.28 |
Source: NEEP ccASHP list · as of