CONTINENTAL vs UTL heat pumps

Measured against models of the same size and duct type, CONTINENTAL scores higher on 4 of the 6 ratings. CONTINENTAL has 31 outdoor models, UTL has 30 outdoor models. CONTINENTAL and UTL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CONTINENTAL and UTL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CONTINENTAL scores higher on 4 of the 6 ratings.
  • CONTINENTAL
  • UTL
  • Other ranked manufacturers
CONTINEN…UTL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCONTINENTALUTL
Efficiency index64%median —64%median —
COP at 5°F52%median 2.0080%median 2.20
Capacity retention at 5°F69% (higher)median 96%58% (higher)median 74%
HSPF277% (higher)median 10.575% (higher)median 9.4
SEER265%median 23.070%median 18.3
EER262% (higher)median 12.544% (higher)median 11.0
Heating capacity at 5°F71% (higher)median 19,000 Btu/h59% (higher)median 25,800 Btu/h
Outdoor models3130
AHRI certifications4938

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCONTINENTALUTL
CEE 2025 Tier 1 (Split ASHP)77.4%24 models86.7%26 models
CEE 2026 Tier 1 (Split ASHP)77.4%24 models86.7%26 models
CEE Advanced Tier (Split ASHP)0%0 models10%3 models
Xcel Energy Colorado cold-climate ASHP (2025)83.9%26 models83.3%25 models
DOE Cold Climate Heat Pump Challenge0%0 models10%3 models
ENERGY STAR Cold Climate83.9%26 models100%30 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • CONTINENTAL
  • UTL
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCONTINENTALUTL
Ducted, up to 1.5 tons1 · index 30%1 · index 52%
Ducted, 2 tons2 · index 51%7 · index 74%
Ducted, 2.5 to 3 tons4 · index 58%9 · index 62%
Ducted, 3.5 to 4.5 tons3 · index 45%13 · index 61%
Non-ducted, up to 1.5 tons12 · index 75%None
Non-ducted, 2 tons3 · index 77%None
Non-ducted, 2.5 to 3 tons8 · index 61%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCONTINENTALCold-climate score, best modelUTLCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)52.2(50 is the typical model of its size class)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models qualify · AHRI 218721137
Ducted, 2 tons76.2(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models qualify · AHRI 21869690789.4(50 is the typical model of its size class) (higher)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN27 of 7 models qualify · AHRI 218472797
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class) (higher)NDHAMB-36-O3 of 4 models qualify · AHRI 21521372977.9(50 is the typical model of its size class)UCHA-36HDCTRN2with ducted air handler UCHA-36HDCALN29 of 9 models qualify · AHRI 218472798
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPCC48ABA13 of 3 models qualify · AHRI 21869691579.8(50 is the typical model of its size class) (higher)UCHA-48HDCTRN2with ducted air handler UCHA-48HDCALN213 of 13 models qualify · AHRI 218472800
Non-ducted, up to 1.5 tons75.2(50 is the typical model of its size class)CDHAS26B-18-Owith ductless indoor unit CDHAS26B-18-IAlso listed as CDHAS26BA-18-O11 of 12 models qualify · AHRI 215213716No models in this size class
Non-ducted, 2 tons89.6(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models qualify · AHRI 215931368No models in this size class
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class)NDHAMB-36-O7 of 8 models qualify · AHRI 215213730No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCONTINENTALAll-around score, best modelUTLAll-around score, best model
Ducted, up to 1.5 tons29.5(50 is the typical model of its size class)WSCHV0018BA1-Cwith ducted air handler WECC24ABA11 of 1 models have all five ratings · AHRI 21846132352.3(50 is the typical model of its size class) (higher)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models have all five ratings · AHRI 218721137
Ducted, 2 tons68.6(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models have all five ratings · AHRI 21869690785.0(50 is the typical model of its size class) (higher)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN27 of 7 models have all five ratings · AHRI 218472797
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)NDHAMB-36-O4 of 4 models have all five ratings · AHRI 21521372966.2(50 is the typical model of its size class)UCHA-36HDCT(O)with ducted air handler UCHA-36HDCT(I)Also listed as UCHA-36HDCT, UCHA-36HDCTN29 of 9 models have all five ratings · AHRI 214771549
Ducted, 3.5 to 4.5 tons67.9(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPFX48A-C3 of 3 models have all five ratings · AHRI 21869691368.7(50 is the typical model of its size class) (higher)UCHA-48HDCTwith ducted air handler UCHA-48HDCAlso listed as UCHA-48HDCT, UCHA-48HDCTN213 of 13 models have all five ratings · AHRI 217014849
Non-ducted, up to 1.5 tons83.1(50 is the typical model of its size class)CDHAMBB-18-O11 of 12 models have all five ratings · AHRI 215931370No models in this size class
Non-ducted, 2 tons78.3(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models have all five ratings · AHRI 215931368No models in this size class
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)CDHAMB-36-OAlso listed as CDHAMBB-36-O8 of 8 models have all five ratings · AHRI 215213728No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCONTINENTALUTL
COP at 5°Fbeats 95% · 2.36CDHAS22B-12-OAlso listed as CDHAS22BA-12-ONon-ducted, up to 1.5 tonsbeats 89% · 2.30UCHA-36HDCTRN2Ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 97% · 113%CDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 92% · 100%UCHA-24HDCSN4Also listed as UCHA-24HDCSN2Ducted, 2 tons
HSPF2beats 98% · 13.5CDHAS26BA-24-ONon-ducted, 2 tonsbeats 91% · 10.5UCHA-48HDCTRN2Ducted, 3.5 to 4.5 tons
SEER2beats 96% · 27.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 86% · 20.0UCHA-24HDCTAlso listed as UCHA-24HDCT, UCHA-24HDCTN2Ducted, 2 tons
EER2beats 95% · 15.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 98% · 14.0UCHA-24HDCTAlso listed as UCHA-24HDCT, UCHA-24HDCTN2Ducted, 2 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hCDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 89% · 24,000 Btu/hUCHA-24HDCSN4Also listed as UCHA-24HDCSN2Ducted, 2 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
CONTINENTAL vs UTL: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • CONTINENTAL (median, middle 50%)
  • UTL (median, middle 50%)
Heating capacity, % of its 47°F maximum72%75%COP at maximum capacity2.002.20

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
CONTINENTAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
CONTINENTAL, 47°F31100%100%100%100%100%
CONTINENTAL, 17°F3168%72%80%85%86%
CONTINENTAL, 5°F3154%62%72%82%93%
CONTINENTAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
CONTINENTAL, 47°F312.792.893.273.443.58
CONTINENTAL, 17°F311.752.12.352.552.69
CONTINENTAL, 5°F311.81.8522.082.35
UTL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
UTL, 47°F16100%100%100%100%100%
UTL, 17°F1683%84%95%100%100%
UTL, 5°F1673%74%75%77%100%
UTL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
UTL, 47°F163.53.53.83.83.8
UTL, 17°F162.12.242.42.422.58
UTL, 5°F162.152.22.22.212.28

Source: NEEP ccASHP list · as of