Skip to content

CONTINENTAL vs VKIN heat pumps

Measured against models of the same size and duct type, CONTINENTAL scores higher on 4 of the 6 ratings. CONTINENTAL has 31 outdoor models, VKIN has 32 outdoor models. CONTINENTAL and VKIN have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CONTINENTAL and VKIN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CONTINENTAL scores higher on 4 of the 6 ratings.
  • CONTINENTAL
  • VKIN
  • Other ranked manufacturers
CONTINEN…VKIN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCONTINENTALVKIN
Efficiency index64% (higher)median —59% (higher)median —
COP at 5°F52%median 2.0052%median 2.00
Capacity retention at 5°F69% (higher)median 96%57% (higher)median 76%
HSPF277% (higher)median 10.562% (higher)median 9.8
SEER265%median 23.072%median 22.5
EER262% (higher)median 12.550% (higher)median 12.0
Heating capacity at 5°F71% (higher)median 19,000 Btu/h57% (higher)median 18,250 Btu/h
Outdoor models3132
AHRI certifications4946

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCONTINENTALVKIN
CEE 2025 Tier 1 (Split ASHP)77.4%24 models93.8%30 models
CEE 2026 Tier 1 (Split ASHP)77.4%24 models93.8%30 models
CEE Advanced Tier (Split ASHP)0%0 models3.1%1 models
Xcel Energy Colorado cold-climate ASHP (2025)83.9%26 models90.6%29 models
DOE Cold Climate Heat Pump Challenge0%0 models3.1%1 models
ENERGY STAR Cold Climate83.9%26 models71.9%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • CONTINENTAL
  • VKIN
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCONTINENTALVKIN
Ducted, up to 1.5 tons1 · index 30%1 · index 53%
Ducted, 2 tons2 · index 51%2 · index 76%
Ducted, 2.5 to 3 tons4 · index 58%4 · index 63%
Ducted, 3.5 to 4.5 tons3 · index 45%6 · index 60%
Non-ducted, up to 1.5 tons12 · index 75%15 · index 62%
Non-ducted, 2 tons3 · index 77%4 · index 51%
Non-ducted, 2.5 to 3 tons8 · index 61%2 · index 59%
Non-ducted, 3.5 to 4.5 tonsNone3 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCONTINENTALCold-climate score, best modelVKINCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)49.0(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554
Ducted, 2 tons76.2(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models qualify · AHRI 21869690780.8(50 is the typical model of its size class) (higher)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class) (higher)NDHAMB-36-O3 of 4 models qualify · AHRI 21521372970.1(50 is the typical model of its size class)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models qualify · AHRI 218385958
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPCC48ABA13 of 3 models qualify · AHRI 21869691576.9(50 is the typical model of its size class) (higher)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962
Non-ducted, up to 1.5 tons75.2(50 is the typical model of its size class)CDHAS26B-18-Owith ductless indoor unit CDHAS26B-18-IAlso listed as CDHAS26BA-18-O11 of 12 models qualify · AHRI 21521371683.4(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652
Non-ducted, 2 tons89.6(50 is the typical model of its size class) (higher)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models qualify · AHRI 21593136859.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class) (higher)NDHAMB-36-O7 of 8 models qualify · AHRI 21521373058.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550
Non-ducted, 3.5 to 4.5 tonsNo models in this size class31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCONTINENTALAll-around score, best modelVKINAll-around score, best model
Ducted, up to 1.5 tons29.5(50 is the typical model of its size class)WSCHV0018BA1-Cwith ducted air handler WECC24ABA11 of 1 models have all five ratings · AHRI 21846132353.1(50 is the typical model of its size class) (higher)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554
Ducted, 2 tons68.6(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models have all five ratings · AHRI 21869690779.2(50 is the typical model of its size class) (higher)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)NDHAMB-36-O4 of 4 models have all five ratings · AHRI 21521372966.2(50 is the typical model of its size class)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models have all five ratings · AHRI 218385958
Ducted, 3.5 to 4.5 tons67.9(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPFX48A-C3 of 3 models have all five ratings · AHRI 21869691368.7(50 is the typical model of its size class) (higher)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957
Non-ducted, up to 1.5 tons83.1(50 is the typical model of its size class)CDHAMBB-18-O11 of 12 models have all five ratings · AHRI 21593137085.1(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652
Non-ducted, 2 tons78.3(50 is the typical model of its size class) (higher)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models have all five ratings · AHRI 21593136860.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)CDHAMB-36-OAlso listed as CDHAMBB-36-O8 of 8 models have all five ratings · AHRI 21521372865.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550
Non-ducted, 3.5 to 4.5 tonsNo models in this size class42.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCONTINENTALVKIN
COP at 5°Fbeats 95% · 2.36CDHAS22B-12-OAlso listed as CDHAS22BA-12-ONon-ducted, up to 1.5 tonsbeats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 113%CDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons
HSPF2beats 98% · 13.5CDHAS26BA-24-ONon-ducted, 2 tonsbeats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons
SEER2beats 96% · 27.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons
EER2beats 95% · 15.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 98% · 14.0UCHA-24HDCTDucted, 2 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hCDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
CONTINENTAL vs VKIN: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • CONTINENTAL (median, middle 50%)
  • VKIN (median, middle 50%)
Heating capacity, % of its 47°F maximum72%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
CONTINENTAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
CONTINENTAL, 47°F31100%100%100%100%100%
CONTINENTAL, 17°F3168%72%80%85%86%
CONTINENTAL, 5°F3154%62%72%82%93%
CONTINENTAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
CONTINENTAL, 47°F312.792.893.273.443.58
CONTINENTAL, 17°F311.752.12.352.552.69
CONTINENTAL, 5°F311.81.8522.082.35
VKIN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F19100%100%100%100%100%
VKIN, 17°F1972%73%80%90%93%
VKIN, 5°F1960%65%71%75%86%
VKIN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F192.432.833.083.53.55
VKIN, 17°F191.932.062.22.352.53
VKIN, 5°F191.81.8222.052.1

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter