Both views use the same certified data. This device remembers your choice.
CONTINENTAL vs VKIN heat pumps
Measured against models of the same size and duct type, CONTINENTAL scores higher on 4 of the 6 ratings. CONTINENTAL has 31 outdoor models, VKIN has 32 outdoor models. CONTINENTAL and VKIN have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CONTINENTAL
- VKIN
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CONTINENTAL | VKIN |
|---|---|---|
| Efficiency index | 64% (higher)median — | 59% (higher)median — |
| COP at 5°F | 52%median 2.00 | 52%median 2.00 |
| Capacity retention at 5°F | 69% (higher)median 96% | 57% (higher)median 76% |
| HSPF2 | 77% (higher)median 10.5 | 62% (higher)median 9.8 |
| SEER2 | 65%median 23.0 | 72%median 22.5 |
| EER2 | 62% (higher)median 12.5 | 50% (higher)median 12.0 |
| Heating capacity at 5°F | 71% (higher)median 19,000 Btu/h | 57% (higher)median 18,250 Btu/h |
| Outdoor models | 31 | 32 |
| AHRI certifications | 49 | 46 |
Share of models meeting each standard
| Standard | CONTINENTAL | VKIN |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 77.4%24 models | 93.8%30 models |
| CEE 2026 Tier 1 (Split ASHP) | 77.4%24 models | 93.8%30 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 3.1%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 83.9%26 models | 90.6%29 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 3.1%1 models |
| ENERGY STAR Cold Climate | 83.9%26 models | 71.9%23 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CONTINENTAL
- VKIN
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CONTINENTAL | VKIN |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 30% | 1 · index 53% |
| Ducted, 2 tons | 2 · index 51% | 2 · index 76% |
| Ducted, 2.5 to 3 tons | 4 · index 58% | 4 · index 63% |
| Ducted, 3.5 to 4.5 tons | 3 · index 45% | 6 · index 60% |
| Non-ducted, up to 1.5 tons | 12 · index 75% | 15 · index 62% |
| Non-ducted, 2 tons | 3 · index 77% | 4 · index 51% |
| Non-ducted, 2.5 to 3 tons | 8 · index 61% | 2 · index 59% |
| Non-ducted, 3.5 to 4.5 tons | None | 3 · index 40% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CONTINENTALCold-climate score, best model | VKINCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 49.0(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554 |
| Ducted, 2 tons | 76.2(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models qualify · AHRI 218696907 | 80.8(50 is the typical model of its size class) (higher)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class) (higher)NDHAMB-36-O3 of 4 models qualify · AHRI 215213729 | 70.1(50 is the typical model of its size class)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models qualify · AHRI 218385958 |
| Ducted, 3.5 to 4.5 tons | 63.3(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPCC48ABA13 of 3 models qualify · AHRI 218696915 | 76.9(50 is the typical model of its size class) (higher)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962 |
| Non-ducted, up to 1.5 tons | 75.2(50 is the typical model of its size class)CDHAS26B-18-Owith ductless indoor unit CDHAS26B-18-IAlso listed as CDHAS26BA-18-O11 of 12 models qualify · AHRI 215213716 | 83.4(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652 |
| Non-ducted, 2 tons | 89.6(50 is the typical model of its size class) (higher)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models qualify · AHRI 215931368 | 59.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class) (higher)NDHAMB-36-O7 of 8 models qualify · AHRI 215213730 | 58.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552 |
All-around best
| Size and duct type | CONTINENTALAll-around score, best model | VKINAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 29.5(50 is the typical model of its size class)WSCHV0018BA1-Cwith ducted air handler WECC24ABA11 of 1 models have all five ratings · AHRI 218461323 | 53.1(50 is the typical model of its size class) (higher)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554 |
| Ducted, 2 tons | 68.6(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models have all five ratings · AHRI 218696907 | 79.2(50 is the typical model of its size class) (higher)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)NDHAMB-36-O4 of 4 models have all five ratings · AHRI 215213729 | 66.2(50 is the typical model of its size class)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models have all five ratings · AHRI 218385958 |
| Ducted, 3.5 to 4.5 tons | 67.9(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPFX48A-C3 of 3 models have all five ratings · AHRI 218696913 | 68.7(50 is the typical model of its size class) (higher)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957 |
| Non-ducted, up to 1.5 tons | 83.1(50 is the typical model of its size class)CDHAMBB-18-O11 of 12 models have all five ratings · AHRI 215931370 | 85.1(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652 |
| Non-ducted, 2 tons | 78.3(50 is the typical model of its size class) (higher)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models have all five ratings · AHRI 215931368 | 60.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class) (higher)CDHAMB-36-OAlso listed as CDHAMBB-36-O8 of 8 models have all five ratings · AHRI 215213728 | 65.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 42.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CONTINENTAL | VKIN |
|---|---|---|
| COP at 5°F | beats 95% · 2.36CDHAS22B-12-OAlso listed as CDHAS22BA-12-ONon-ducted, up to 1.5 tons | beats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 113%CDHAS26B-24-ONon-ducted, up to 1.5 tons | beats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons |
| HSPF2 | beats 98% · 13.5CDHAS26BA-24-ONon-ducted, 2 tons | beats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons |
| SEER2 | beats 96% · 27.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tons | beats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons |
| EER2 | beats 95% · 15.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tons | beats 98% · 14.0UCHA-24HDCTDucted, 2 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/hCDHAS26B-24-ONon-ducted, up to 1.5 tons | beats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- CONTINENTAL (median, middle 50%)
- VKIN (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| CONTINENTAL, 47°F | 31 | 100% | 100% | 100% | 100% | 100% |
| CONTINENTAL, 17°F | 31 | 68% | 72% | 80% | 85% | 86% |
| CONTINENTAL, 5°F | 31 | 54% | 62% | 72% | 82% | 93% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| CONTINENTAL, 47°F | 31 | 2.79 | 2.89 | 3.27 | 3.44 | 3.58 |
| CONTINENTAL, 17°F | 31 | 1.75 | 2.1 | 2.35 | 2.55 | 2.69 |
| CONTINENTAL, 5°F | 31 | 1.8 | 1.85 | 2 | 2.08 | 2.35 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 100% | 100% | 100% | 100% | 100% |
| VKIN, 17°F | 19 | 72% | 73% | 80% | 90% | 93% |
| VKIN, 5°F | 19 | 60% | 65% | 71% | 75% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 2.43 | 2.83 | 3.08 | 3.5 | 3.55 |
| VKIN, 17°F | 19 | 1.93 | 2.06 | 2.2 | 2.35 | 2.53 |
| VKIN, 5°F | 19 | 1.8 | 1.82 | 2 | 2.05 | 2.1 |
Source: NEEP ccASHP list · as of