Both views use the same certified data. This device remembers your choice.
VKIN heat pump efficiency: 33 outdoor models compared
VKIN has 33 heat pump outdoor models certified with this refrigerant group, in 51 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes VKIN makes. VKIN has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 33
- AHRI certifications
- 51
- Efficiency index
- 60%
- Typical model vs same-size, same-type peers (38 models)
- Meet CEE 2025
- 93.9%
- 31 models
How VKIN compares with comparable models
- VKIN
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index38 models scored | 60% | Not ranked | — |
| COP at 5°F38 models scored | 53% | Not ranked | 2.00 |
| Capacity retention at 5°F38 models scored | 57% | Not ranked | 76% |
| HSPF238 models scored | 62% | Not ranked | 9.8 |
| SEER238 models scored | 72% | Not ranked | 22.5 |
| EER238 models scored | 51% | Not ranked | 12.0 |
| Heating capacity at 5°F38 models scored | 57% | Not ranked | 18,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 93.9% | 31 |
| CEE 2026 Tier 1 (Split ASHP) | 93.9% | 31 |
| CEE Advanced Tier (Split ASHP) | 3% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 90.9% | 30 |
| DOE Cold Climate Heat Pump Challenge | 3% | 1 |
| ENERGY STAR Cold Climate | 69.7% | 23 |
Sizes and duct types offered
- VKIN (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 54% | 50% | 35% | 83% |
| Ducted, 2 tons | 2 | 77% | 77% | 72% | 77% |
| Ducted, 2.5 to 3 tons | 5 | 67% | 63% | 77% | 83% |
| Ducted, 3.5 to 4.5 tons | 6 | 60% | 63% | 76% | 76% |
| Non-ducted, up to 1.5 tons | 15 | 62% | 55% | 64% | 65% |
| Non-ducted, 2 tons | 4 | 51% | 24% | 45% | 65% |
| Non-ducted, 2.5 to 3 tons | 2 | 59% | 53% | 70% | 79% |
| Non-ducted, 3.5 to 4.5 tons | 3 | 40% | 32% | 23% | 79% |
Every VKIN model in the market
- VKIN models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
VKIN in the cold
- All listed models (median, middle 50% and 80%)
- VKIN (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 100% | 100% | 100% | 100% | 100% |
| VKIN, 17°F | 19 | 72% | 73% | 80% | 90% | 93% |
| VKIN, 5°F | 19 | 60% | 65% | 71% | 75% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 2.43 | 2.83 | 3.08 | 3.5 | 3.55 |
| VKIN, 17°F | 19 | 1.93 | 2.06 | 2.2 | 2.35 | 2.53 |
| VKIN, 5°F | 19 | 1.8 | 1.82 | 2 | 2.05 | 2.1 |
Source: NEEP ccASHP list · as of
Top VKIN models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1URHA-09WDCN4(O)VKIN · HiULTRAwith ductless indoor unit URHA-09WDCN4(I) | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.09 | 11.0 | 9,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 216498652 | Non-ducted, up to 1.5 tons | 83.4 |
| 2UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN4 | 3 tons34,200 Btu/h · Ducted | 82% | 2.35 | 10.0 | 28,200 | 18.5 | CEE 25CEE 26Xcel | 1 | 219136484 | Ducted, 2.5 to 3 tons | 81.2 |
| 3UCHA-24HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN4 | 2 tons24,000 Btu/h · Ducted | 100% | 2.20 | 9.5 | 24,000 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218385960 | Ducted, 2 tons | 80.8 |
| 4UCHA-48HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCN4 | 4 tons48,000 Btu/h · Ducted | 75% | 2.25 | 9.8 | 36,000 | 17.5 | CEE 25CEE 26XcelES CC | 3 | 218385962 | Ducted, 3.5 to 4.5 tons | 76.8 |
| 5UCHA-48HDCTVKIN · AHUwith ducted air handler UCHA-48HDC | 4 tons48,000 Btu/h · Ducted | 73% | 2.20 | 9.8 | 35,000 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218385957 | Ducted, 3.5 to 4.5 tons | 73.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1URHA-09WDCN4(O)VKIN · HiULTRAwith ductless indoor unit URHA-09WDCN4(I) | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.09 | 11.0 | 25.0 | 13.7 | CEE 25CEE 26XcelES CC | 1 | 216498652 | Non-ducted, up to 1.5 tons | 85.1 | 83.4 | 86.7 | 83.4 |
| 2UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN4 | 3 tons34,200 Btu/h · Ducted | 82% | 2.35 | 10.0 | 18.5 | 12.5 | CEE 25CEE 26Xcel | 1 | 219136484 | Ducted, 2.5 to 3 tons | 83.1 | 81.2 | 85.0 | 81.2 |
| 3UCHA-24HDCTVKIN · AHUwith ducted air handler UCHA-24HDC | 2 tons24,000 Btu/h · Ducted | 74% | 2.20 | 9.5 | 20.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218385956 | Ducted, 2 tons | 79.2 | 65.0 | 93.4 | 65.0 |
| 4URHT-12WDCN4-SE25(O)VKIN · T-prowith ductless indoor unit URHT-12WDCN4-SE25(I) | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26Xcel | 1 | 218858155 | Non-ducted, up to 1.5 tons | 75.6 | 63.4 | 87.9 | 63.4 |
| 5URHT-18FM2N4VKIN · T-pro | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26XcelES CC | 3 | 218258549 | Non-ducted, up to 1.5 tons | 73.9 | 70.1 | 77.8 | 70.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | URHA-18WDCNX-O | 2.49 | Non-ducted, up to 1.5 tons | 98% | 216012254 |
| Capacity retention at 5°F | UCHA-24HDCSN4 | 100% | Ducted, 2 tons | 92% | 218385960 |
| HSPF2 | URHT-36FM4N4 | 10.5 | Ducted, 2.5 to 3 tons | 96% | 218258556 |
| SEER2 | URHT-27FM3N4 | 21.0 | Ducted, 2.5 to 3 tons | 98% | 218258555 |
| EER2 | UCHA-24HDCT | 14.0 | Ducted, 2 tons | 98% | 218385956 |
| Heating capacity at 5°F | URHA-18WDCN4(O) | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 94% | 216498654 |
VKIN size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 49.4(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554 | 53.5(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554 |
| Ducted, 2 tons | 80.8(50 is the typical model of its size class)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960 | 79.2(50 is the typical model of its size class)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956 |
| Ducted, 2.5 to 3 tons | 81.2(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models qualify · AHRI 219136484 | 83.1(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models have all five ratings · AHRI 219136484 |
| Ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962 | 68.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957 |
| Non-ducted, up to 1.5 tons | 83.4(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652 | 85.1(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652 |
| Non-ducted, 2 tons | 59.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157 | 60.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655 |
| Non-ducted, 2.5 to 3 tons | 58.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550 | 65.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550 |
| Non-ducted, 3.5 to 4.5 tons | 31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552 | 42.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552 |
Newest VKIN certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| UCHA-60HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-60HDCALN4 | 4.5 tons54,000 Btu/h · Ducted | 2.20 | 74% | 9.0 | 16.7 | CEE 25CEE 26XcelES CC | 3 | 219136488 |
| UCHA-48HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCALN4 | 4 tons48,000 Btu/h · Ducted | 2.25 | 75% | 9.8 | 17.5 | CEE 25CEE 26XcelES CC | 3 | 219136486 |
| UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN4 | 3 tons34,200 Btu/h · Ducted | 2.35 | 82% | 10.0 | 18.5 | CEE 25CEE 26Xcel | 1 | 219136484 |
| UCHA-36HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN4 | 3 tons34,200 Btu/h · Ducted | 2.10 | 76% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 3 | 219136482 |
| UCHA-24HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCALN4 | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 219136480 |
Compare VKIN
VKIN includes these brand names as listed in AHRI: VKIN. Standards are checked against published thresholds; program rules beyond ratings are not checked.