Skip to content

VKIN heat pump efficiency: 33 outdoor models compared

VKIN has 33 heat pump outdoor models certified with this refrigerant group, in 51 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes VKIN makes. VKIN has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
33
AHRI certifications
51
Efficiency index
60%
Typical model vs same-size, same-type peers (38 models)
Meet CEE 2025
93.9%
31 models

How VKIN compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
VKIN against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of VKIN’s own modelsVKIN is strongest on SEER2 (its typical model beats 72% of comparable models) and weakest on EER2 (51%).
  • VKIN
  • Middle half of its models
  • Other ranked manufacturers
VKIN

Source: AHRI Directory, NEEP · as of

Average peer percentile of VKIN’s models
RatingBeats comparable modelsRankRaw median
Efficiency index38 models scored60%Not ranked—
COP at 5°F38 models scored53%Not ranked2.00
Capacity retention at 5°F38 models scored57%Not ranked76%
HSPF238 models scored62%Not ranked9.8
SEER238 models scored72%Not ranked22.5
EER238 models scored51%Not ranked12.0
Heating capacity at 5°F38 models scored57%Not ranked18,500 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
VKIN’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • VKIN (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons154%50%35%83%
Ducted, 2 tons277%77%72%77%
Ducted, 2.5 to 3 tons567%63%77%83%
Ducted, 3.5 to 4.5 tons660%63%76%76%
Non-ducted, up to 1.5 tons1562%55%64%65%
Non-ducted, 2 tons451%24%45%65%
Non-ducted, 2.5 to 3 tons259%53%70%79%
Non-ducted, 3.5 to 4.5 tons340%32%23%79%

Every VKIN model in the market

VKIN’s 38 models with a known size and duct type, over the shape of the whole catalog.
VKIN models by size and ratingColoured: VKIN · grey shapes: all 15,936 models · lines: catalog medians by size
  • VKIN models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 38 vkin models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

VKIN in the cold

From NEEP’s cold-climate listings: 19 VKIN models against all 6,343 listed models.
VKIN capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical VKIN model keeps 71% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • VKIN (median, middle 50%)
Heating capacity, % of its 47°F maximum71%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
VKIN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F19100%100%100%100%100%
VKIN, 17°F1972%73%80%90%93%
VKIN, 5°F1960%65%71%75%86%
VKIN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F192.432.833.083.53.55
VKIN, 17°F191.932.062.22.352.53
VKIN, 5°F191.81.8222.052.1

Source: NEEP ccASHP list · as of

Top VKIN models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 VKIN cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1URHA-09WDCN4(O)VKIN · HiULTRAwith ductless indoor unit URHA-09WDCN4(I)1 ton9,000 Btu/h · Non-ducted100%2.0911.09,00025.0CEE 25CEE 26XcelES CC1216498652Non-ducted, up to 1.5 tons83.4
2UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN43 tons34,200 Btu/h · Ducted82%2.3510.028,20018.5CEE 25CEE 26Xcel1219136484Ducted, 2.5 to 3 tons81.2
3UCHA-24HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN42 tons24,000 Btu/h · Ducted100%2.209.524,00018.5CEE 25CEE 26CEE AdvXcelDOEES CC3218385960Ducted, 2 tons80.8
4UCHA-48HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCN44 tons48,000 Btu/h · Ducted75%2.259.836,00017.5CEE 25CEE 26XcelES CC3218385962Ducted, 3.5 to 4.5 tons76.8
5UCHA-48HDCTVKIN · AHUwith ducted air handler UCHA-48HDC4 tons48,000 Btu/h · Ducted73%2.209.835,00018.5CEE 25CEE 26XcelES CC1218385957Ducted, 3.5 to 4.5 tons73.5

All-around best

Top 5 VKIN models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1URHA-09WDCN4(O)VKIN · HiULTRAwith ductless indoor unit URHA-09WDCN4(I)1 ton9,000 Btu/h · Non-ducted100%2.0911.025.013.7CEE 25CEE 26XcelES CC1216498652Non-ducted, up to 1.5 tons85.183.486.783.4
2UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN43 tons34,200 Btu/h · Ducted82%2.3510.018.512.5CEE 25CEE 26Xcel1219136484Ducted, 2.5 to 3 tons83.181.285.081.2
3UCHA-24HDCTVKIN · AHUwith ducted air handler UCHA-24HDC2 tons24,000 Btu/h · Ducted74%2.209.520.014.0CEE 25CEE 26XcelES CC1218385956Ducted, 2 tons79.265.093.465.0
4URHT-12WDCN4-SE25(O)VKIN · T-prowith ductless indoor unit URHT-12WDCN4-SE25(I)1 ton12,000 Btu/h · Non-ducted100%1.8010.525.014.0CEE 25CEE 26Xcel1218858155Non-ducted, up to 1.5 tons75.663.487.963.4
5URHT-18FM2N4VKIN · T-pro1.5 tons18,000 Btu/h · Non-ducted80%2.0010.524.013.0CEE 25CEE 26XcelES CC3218258549Non-ducted, up to 1.5 tons73.970.177.870.1

Best model on each rating

VKIN’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FURHA-18WDCNX-O2.49Non-ducted, up to 1.5 tons98%216012254
Capacity retention at 5°FUCHA-24HDCSN4100%Ducted, 2 tons92%218385960
HSPF2URHT-36FM4N410.5Ducted, 2.5 to 3 tons96%218258556
SEER2URHT-27FM3N421.0Ducted, 2.5 to 3 tons98%218258555
EER2UCHA-24HDCT14.0Ducted, 2 tons98%218385956
Heating capacity at 5°FURHA-18WDCN4(O)18,000 Btu/hNon-ducted, up to 1.5 tons94%216498654

All 33 VKIN models in Explore

VKIN size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
VKIN: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons49.4(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 21825855453.5(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554
Ducted, 2 tons80.8(50 is the typical model of its size class)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 21838596079.2(50 is the typical model of its size class)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956
Ducted, 2.5 to 3 tons81.2(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models qualify · AHRI 21913648483.1(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models have all five ratings · AHRI 219136484
Ducted, 3.5 to 4.5 tons76.8(50 is the typical model of its size class)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 21838596268.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 21649865285.1(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652
Non-ducted, 2 tons59.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 21885815760.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655
Non-ducted, 2.5 to 3 tons58.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 21825855065.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550
Non-ducted, 3.5 to 4.5 tons31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 21825855242.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552

All-around board, every manufacturer

Newest VKIN certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified VKIN outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
UCHA-60HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-60HDCALN44.5 tons54,000 Btu/h · Ducted2.2074%9.016.7CEE 25CEE 26XcelES CC3219136488
UCHA-48HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCALN44 tons48,000 Btu/h · Ducted2.2575%9.817.5CEE 25CEE 26XcelES CC3219136486
UCHA-36HDCSALN4-LHVKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN43 tons34,200 Btu/h · Ducted2.3582%10.018.5CEE 25CEE 26Xcel1219136484
UCHA-36HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-36HDCALN43 tons34,200 Btu/h · Ducted2.1076%9.018.0CEE 25CEE 26XcelES CC3219136482
UCHA-24HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCALN42 tons24,000 Btu/h · Ducted2.20100%9.518.5CEE 25CEE 26CEE AdvXcelDOEES CC3219136480

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for VKIN in this group.

Compare VKIN

Manufacturers of a similar size, side by side.

VKIN includes these brand names as listed in AHRI: VKIN. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter