Both views use the same certified data. This device remembers your choice.
Senville vs VKIN heat pumps
Measured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings. Senville has 34 outdoor models, VKIN has 33 outdoor models. VKIN has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Senville
- VKIN
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Senville | VKIN |
|---|---|---|
| Efficiency index | 65% (higher)median — · 2nd ranked | 60% (higher)median — |
| COP at 5°F | 57% (higher)median 2.00 · 13th ranked | 53% (higher)median 2.00 |
| Capacity retention at 5°F | 69% (higher)median 91% · 1st ranked | 57% (higher)median 76% |
| HSPF2 | 73% (higher)median 10.0 · 2nd ranked | 62% (higher)median 9.8 |
| SEER2 | 69%median 21.1 · 1st ranked | 72%median 22.5 |
| EER2 | 62% (higher)median 12.0 · 6th ranked | 51% (higher)median 12.0 |
| Heating capacity at 5°F | 66% (higher)median 21,200 Btu/h · 3rd ranked | 57% (higher)median 18,500 Btu/h |
| Outdoor models | 34 | 33 |
| AHRI certifications | 64 | 51 |
Share of models meeting each standard
| Standard | Senville | VKIN |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 82.4%28 models | 93.9%31 models |
| CEE 2026 Tier 1 (Split ASHP) | 79.4%27 models | 93.9%31 models |
| CEE Advanced Tier (Split ASHP) | 2.9%1 models | 3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 73.5%25 models | 90.9%30 models |
| DOE Cold Climate Heat Pump Challenge | 2.9%1 models | 3%1 models |
| ENERGY STAR Cold Climate | 70.6%24 models | 69.7%23 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Senville
- VKIN
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Senville | VKIN |
|---|---|---|
| Ducted, up to 1.5 tons | 4 · index 78% | 1 · index 54% |
| Ducted, 2 tons | 4 · index 77% | 2 · index 77% |
| Ducted, 2.5 to 3 tons | 5 · index 69% | 5 · index 67% |
| Ducted, 3.5 to 4.5 tons | 6 · index 62% | 6 · index 60% |
| Non-ducted, up to 1.5 tons | 15 · index 64% | 15 · index 62% |
| Non-ducted, 2 tons | 2 · index 56% | 4 · index 51% |
| Non-ducted, 2.5 to 3 tons | 5 · index 48% | 2 · index 59% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 67% | 3 · index 40% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | SenvilleCold-climate score, best model | VKINCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 80.6(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models qualify · AHRI 215735300 | 49.4(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ducted air handler SENA-24HF-IDG4 of 4 models qualify · AHRI 215735303 | 80.8(50 is the typical model of its size class)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class) (higher)SENA-36HF-MOA4 of 5 models qualify · AHRI 215735318 | 81.2(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models qualify · AHRI 219136484 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class) (higher)SENA-48HF-MOA4 of 6 models qualify · AHRI 215735321 | 76.8(50 is the typical model of its size class)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG9 of 15 models qualify · AHRI 215735294 | 83.4(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-ICG2 of 2 models qualify · AHRI 215735307 | 59.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class) (higher)SENA-36HF-MOA3 of 5 models qualify · AHRI 215735319 | 58.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models qualify · AHRI 215735322 | 31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552 |
All-around best
| Size and duct type | SenvilleAll-around score, best model | VKINAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.1(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models have all five ratings · AHRI 215735300 | 53.5(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554 |
| Ducted, 2 tons | 90.0(50 is the typical model of its size class) (higher)SENE-24EL-OHwith ducted air handler SENE-24EL-IHH4 of 4 models have all five ratings · AHRI 218069801 | 79.2(50 is the typical model of its size class)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735318 | 83.1(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models have all five ratings · AHRI 219136484 |
| Ducted, 3.5 to 4.5 tons | 84.3(50 is the typical model of its size class) (higher)SENA-48HF-MOA6 of 6 models have all five ratings · AHRI 215735321 | 68.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG13 of 15 models have all five ratings · AHRI 215735294 | 85.1(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652 |
| Non-ducted, 2 tons | 78.3(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-IGG2 of 2 models have all five ratings · AHRI 215735298 | 60.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735317 | 65.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models have all five ratings · AHRI 215735320 | 42.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Senville | VKIN |
|---|---|---|
| COP at 5°F | beats 97% · 2.40SENA-06HF-OGNon-ducted, up to 1.5 tons | beats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 113%SENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tons | beats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons |
| HSPF2 | beats 99% · 14.8SENA-06HF-OGNon-ducted, up to 1.5 tons | beats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons |
| SEER2 | beats 100% · 25.0SENE-24EL-OHDucted, 2 tons | beats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons |
| EER2 | beats 99% · 18.0SENA-06HF-OGNon-ducted, up to 1.5 tons | beats 98% · 14.0UCHA-24HDCTDucted, 2 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/hSENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tons | beats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Senville (median, middle 50%)
- VKIN (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Senville, 47°F | 30 | 100% | 100% | 100% | 100% | 100% |
| Senville, 17°F | 30 | 69% | 74% | 78% | 84% | 86% |
| Senville, 5°F | 30 | 60% | 65% | 76% | 81% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Senville, 47°F | 30 | 2.91 | 3.09 | 3.21 | 3.43 | 3.57 |
| Senville, 17°F | 30 | 2.08 | 2.14 | 2.31 | 2.5 | 2.62 |
| Senville, 5°F | 30 | 1.84 | 1.9 | 2 | 2.09 | 2.34 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 100% | 100% | 100% | 100% | 100% |
| VKIN, 17°F | 19 | 72% | 73% | 80% | 90% | 93% |
| VKIN, 5°F | 19 | 60% | 65% | 71% | 75% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| VKIN, 47°F | 19 | 2.43 | 2.83 | 3.08 | 3.5 | 3.55 |
| VKIN, 17°F | 19 | 1.93 | 2.06 | 2.2 | 2.35 | 2.53 |
| VKIN, 5°F | 19 | 1.8 | 1.82 | 2 | 2.05 | 2.1 |
Source: NEEP ccASHP list · as of