Senville vs VKIN heat pumps

Measured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings. Senville has 34 outdoor models, VKIN has 33 outdoor models. VKIN has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Senville and VKIN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings.
  • Senville
  • VKIN
  • Other ranked manufacturers
SenvilleVKIN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingSenvilleVKIN
Efficiency index65% (higher)median — · 2nd ranked60% (higher)median —
COP at 5°F57% (higher)median 2.00 · 13th ranked53% (higher)median 2.00
Capacity retention at 5°F69% (higher)median 91% · 1st ranked57% (higher)median 76%
HSPF273% (higher)median 10.0 · 2nd ranked62% (higher)median 9.8
SEER269%median 21.1 · 1st ranked72%median 22.5
EER262% (higher)median 12.0 · 6th ranked51% (higher)median 12.0
Heating capacity at 5°F66% (higher)median 21,200 Btu/h · 3rd ranked57% (higher)median 18,500 Btu/h
Outdoor models3433
AHRI certifications6451

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardSenvilleVKIN
CEE 2025 Tier 1 (Split ASHP)82.4%28 models93.9%31 models
CEE 2026 Tier 1 (Split ASHP)79.4%27 models93.9%31 models
CEE Advanced Tier (Split ASHP)2.9%1 models3%1 models
Xcel Energy Colorado cold-climate ASHP (2025)73.5%25 models90.9%30 models
DOE Cold Climate Heat Pump Challenge2.9%1 models3%1 models
ENERGY STAR Cold Climate70.6%24 models69.7%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Senville
  • VKIN
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeSenvilleVKIN
Ducted, up to 1.5 tons4 · index 78%1 · index 54%
Ducted, 2 tons4 · index 77%2 · index 77%
Ducted, 2.5 to 3 tons5 · index 69%5 · index 67%
Ducted, 3.5 to 4.5 tons6 · index 62%6 · index 60%
Non-ducted, up to 1.5 tons15 · index 64%15 · index 62%
Non-ducted, 2 tons2 · index 56%4 · index 51%
Non-ducted, 2.5 to 3 tons5 · index 48%2 · index 59%
Non-ducted, 3.5 to 4.5 tons2 · index 67%3 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeSenvilleCold-climate score, best modelVKINCold-climate score, best model
Ducted, up to 1.5 tons80.6(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models qualify · AHRI 21573530049.4(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ducted air handler SENA-24HF-IDG4 of 4 models qualify · AHRI 21573530380.8(50 is the typical model of its size class)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class) (higher)SENA-36HF-MOA4 of 5 models qualify · AHRI 21573531881.2(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models qualify · AHRI 219136484
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class) (higher)SENA-48HF-MOA4 of 6 models qualify · AHRI 21573532176.8(50 is the typical model of its size class)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG9 of 15 models qualify · AHRI 21573529483.4(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-ICG2 of 2 models qualify · AHRI 21573530759.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class) (higher)SENA-36HF-MOA3 of 5 models qualify · AHRI 21573531958.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models qualify · AHRI 21573532231.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeSenvilleAll-around score, best modelVKINAll-around score, best model
Ducted, up to 1.5 tons87.1(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models have all five ratings · AHRI 21573530053.5(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554
Ducted, 2 tons90.0(50 is the typical model of its size class) (higher)SENE-24EL-OHwith ducted air handler SENE-24EL-IHH4 of 4 models have all five ratings · AHRI 21806980179.2(50 is the typical model of its size class)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 21573531883.1(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models have all five ratings · AHRI 219136484
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class) (higher)SENA-48HF-MOA6 of 6 models have all five ratings · AHRI 21573532168.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG13 of 15 models have all five ratings · AHRI 21573529485.1(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652
Non-ducted, 2 tons78.3(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-IGG2 of 2 models have all five ratings · AHRI 21573529860.3(50 is the typical model of its size class)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 21573531765.9(50 is the typical model of its size class)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models have all five ratings · AHRI 21573532042.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingSenvilleVKIN
COP at 5°Fbeats 97% · 2.40SENA-06HF-OGNon-ducted, up to 1.5 tonsbeats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 113%SENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tonsbeats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons
HSPF2beats 99% · 14.8SENA-06HF-OGNon-ducted, up to 1.5 tonsbeats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons
SEER2beats 100% · 25.0SENE-24EL-OHDucted, 2 tonsbeats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons
EER2beats 99% · 18.0SENA-06HF-OGNon-ducted, up to 1.5 tonsbeats 98% · 14.0UCHA-24HDCTDucted, 2 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hSENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tonsbeats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Senville vs VKIN: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Senville (median, middle 50%)
  • VKIN (median, middle 50%)
Heating capacity, % of its 47°F maximum76%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Senville: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F30100%100%100%100%100%
Senville, 17°F3069%74%78%84%86%
Senville, 5°F3060%65%76%81%82%
Senville: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F302.913.093.213.433.57
Senville, 17°F302.082.142.312.52.62
Senville, 5°F301.841.922.092.34
VKIN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F19100%100%100%100%100%
VKIN, 17°F1972%73%80%90%93%
VKIN, 5°F1960%65%71%75%86%
VKIN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
VKIN, 47°F192.432.833.083.53.55
VKIN, 17°F191.932.062.22.352.53
VKIN, 5°F191.81.8222.052.1

Source: NEEP ccASHP list · as of