Skip to content

Ozone Spirit vs VKIN heat pumps

Measured against models of the same size and duct type, VKIN scores higher on 5 of the 6 ratings. Ozone Spirit has 34 outdoor models, VKIN has 33 outdoor models. Ozone Spirit and VKIN have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Ozone Spirit and VKIN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, VKIN scores higher on 5 of the 6 ratings.
  • Ozone Spirit
  • VKIN
  • Other ranked manufacturers
Ozone S…VKIN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingOzone SpiritVKIN
Efficiency index31%median —60%median —
COP at 5°F66% (higher)median 2.1653% (higher)median 2.00
Capacity retention at 5°F9%median 57%57%median 76%
HSPF210%median 8.362%median 9.8
SEER217%median 18.572%median 22.5
EER218%median 9.751%median 12.0
Heating capacity at 5°F19%median 8,200 Btu/h57%median 18,500 Btu/h
Outdoor models3433
AHRI certifications3851

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardOzone SpiritVKIN
CEE 2025 Tier 1 (Split ASHP)14.7%5 models93.9%31 models
CEE 2026 Tier 1 (Split ASHP)14.7%5 models93.9%31 models
CEE Advanced Tier (Split ASHP)0%0 models3%1 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models90.9%30 models
DOE Cold Climate Heat Pump Challenge0%0 models3%1 models
ENERGY STAR Cold Climate0%0 models69.7%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • Ozone Spirit
  • VKIN
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeOzone SpiritVKIN
Ducted, up to 1.5 tonsNone1 · index 54%
Ducted, 2 tonsNone2 · index 77%
Ducted, 2.5 to 3 tonsNone5 · index 67%
Ducted, 3.5 to 4.5 tonsNone6 · index 60%
Non-ducted, up to 1.5 tons19 · index 29%15 · index 62%
Non-ducted, 2 tons7 · index 39%4 · index 51%
Non-ducted, 2.5 to 3 tons8 · index 26%2 · index 59%
Non-ducted, 3.5 to 4.5 tonsNone3 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeOzone SpiritCold-climate score, best modelVKINCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class49.4(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554
Ducted, 2 tonsNo models in this size class80.8(50 is the typical model of its size class)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960
Ducted, 2.5 to 3 tonsNo models in this size class81.2(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models qualify · AHRI 219136484
Ducted, 3.5 to 4.5 tonsNo models in this size class76.8(50 is the typical model of its size class)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962
Non-ducted, up to 1.5 tonsNone on this board (0 of 19 models qualify)83.4(50 is the typical model of its size class)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652
Non-ducted, 2 tonsNone on this board (0 of 7 models qualify)59.1(50 is the typical model of its size class)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 8 models qualify)58.2(50 is the typical model of its size class)URHT-27FM3N42 of 2 models qualify · AHRI 218258550
Non-ducted, 3.5 to 4.5 tonsNo models in this size class31.5(50 is the typical model of its size class)URHT-42FM5N43 of 3 models qualify · AHRI 218258552

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeOzone SpiritAll-around score, best modelVKINAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class53.5(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554
Ducted, 2 tonsNo models in this size class79.2(50 is the typical model of its size class)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956
Ducted, 2.5 to 3 tonsNo models in this size class83.1(50 is the typical model of its size class)UCHA-36HDCSALN4-LHwith ducted air handler UCHA-36HDCALN45 of 5 models have all five ratings · AHRI 219136484
Ducted, 3.5 to 4.5 tonsNo models in this size class68.7(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957
Non-ducted, up to 1.5 tons51.7(50 is the typical model of its size class)COPXIH122Awith ductless indoor unit EOPXIH122A5 of 19 models have all five ratings · AHRI 21466027885.1(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652
Non-ducted, 2 tons50.6(50 is the typical model of its size class)COPXIH242Awith ductless indoor unit EOPXIH242A2 of 7 models have all five ratings · AHRI 21466028060.3(50 is the typical model of its size class) (higher)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655
Non-ducted, 2.5 to 3 tons26.0(50 is the typical model of its size class)COPXIH362Bwith ductless indoor unit EOPXIH362B/COPXIH362B1 of 8 models have all five ratings · AHRI 21804543565.9(50 is the typical model of its size class) (higher)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550
Non-ducted, 3.5 to 4.5 tonsNo models in this size class42.3(50 is the typical model of its size class)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingOzone SpiritVKIN
COP at 5°Fbeats 99% · 2.44COPXIH362BNon-ducted, 2.5 to 3 tonsbeats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 19% · 67%COPXIH122ANon-ducted, up to 1.5 tonsbeats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons
HSPF2beats 71% · 10.0COPXIH242ANon-ducted, 2 tonsbeats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons
SEER2beats 50% · 21.0COPXIH242ANon-ducted, 2 tonsbeats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons
EER2beats 56% · 12.0COPXIH242ANon-ducted, 2 tonsbeats 98% · 14.0UCHA-24HDCTDucted, 2 tons
Heating capacity at 5°Fbeats 68% · 11,600 Btu/hCOPXIH182ANon-ducted, up to 1.5 tonsbeats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter