- Insights
- Manufacturers
- CONTINENTAL
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CONTINENTAL heat pump efficiency: 31 outdoor models compared
CONTINENTAL has 31 heat pump outdoor models certified with this refrigerant group, in 45 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes CONTINENTAL makes. CONTINENTAL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 31
- AHRI certifications
- 45
- Efficiency index
- 63%
- Typical model vs same-size, same-type peers (32 models)
- Meet CEE 2025
- 77.4%
- 24 models
How CONTINENTAL compares with comparable models
- CONTINENTAL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index32 models scored | 63% | Not ranked | — |
| COP at 5°F33 models scored | 52% | Not ranked | 2.00 |
| Capacity retention at 5°F33 models scored | 67% | Not ranked | 96% |
| HSPF232 models scored | 76% | Not ranked | 10.5 |
| SEER233 models scored | 64% | Not ranked | 23.0 |
| EER233 models scored | 61% | Not ranked | 12.5 |
| Heating capacity at 5°F33 models scored | 70% | Not ranked | 19,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 77.4% | 24 |
| CEE 2026 Tier 1 (Split ASHP) | 77.4% | 24 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 83.9% | 26 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 83.9% | 26 |
Sizes and duct types offered
- CONTINENTAL (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 29% | 37% | 29% | 51% |
| Ducted, 2 tons | 2 | 51% | 36% | 71% | 46% |
| Ducted, 2.5–3 tons | 4 | 58% | 51% | 70% | 60% |
| Ducted, 3.5–4.5 tons | 3 | 44% | 26% | 64% | 43% |
| Non-ducted, up to 1.5 tons | 12 | 73% | 59% | 87% | 80% |
| Non-ducted, 2 tons | 3 | 75% | 85% | 79% | 76% |
| Non-ducted, 2.5–3 tons | 8 | 61% | 43% | 75% | 51% |
Every CONTINENTAL model in the market
- CONTINENTAL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top CONTINENTAL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CDHAS26BA-24-OCONTINENTAL · CDH Serieswith ductless indoor unit CDHAS26BA-24-I | 2 tons24,000 Btu/h · Non-ducted | 83% | 2.34 | 13.5 | 24,200 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 215931368 | Non-ducted, 2 tons | 88.4 |
| 2NDHAMB-36-OCONTINENTAL · CDH Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26XcelES CC | 2 | 215213729 | Ducted, 2.5–3 tons | 82.5 |
| 3NDHAMB-36-OCONTINENTAL · CDH Series | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.6 | 37,000 | 21.2 | CEE 25CEE 26XcelES CC | 2 | 215213730 | Non-ducted, 2.5–3 tons | 78.0 |
| 4WSEHV2436BA1-CCONTINENTAL · F Serieswith ducted air handler WPFX24A-C | 2 tons24,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 24,000 | 18.0 | CEE 25CEE 26XcelES CC | 4 | 218696907 | Ducted, 2 tons | 76.2 |
| 5CDHAMB-36-OCONTINENTAL · CDH SeriesAlso listed as CDHAMBB-36-O | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.00 | 10.7 | 36,000 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 215213728 | Non-ducted, 2.5–3 tons | 76.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1NDHAMB-36-OCONTINENTAL · CDH Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26XcelES CC | 2 | 215213729 | Ducted, 2.5–3 tons | 83.6 | 82.5 | 84.8 | 82.5 |
| 2CDHAMBB-18-OCONTINENTAL · CDH Series | 1.5 tons19,000 Btu/h · Non-ducted | 95% | 2.00 | 10.4 | 25.0 | 15.0 | CEE 25CEE 26XcelES CC | 1 | 215931370 | Non-ducted, up to 1.5 tons | 81.9 | 73.1 | 90.8 | 73.1 |
| 3CDHAS26B-09-OCONTINENTAL · CDH Serieswith ductless indoor unit CDHAS26B-09-IAlso listed as CDHAS26BA-09-O | 1 ton9,000 Btu/h · Non-ducted | 96% | 1.80 | 12.5 | 27.4 | 15.4 | CEE 25CEE 26XcelES CC | 1 | 215213714 | Non-ducted, up to 1.5 tons | 80.6 | 65.1 | 96.1 | 65.1 |
| 4CDHAMB-36-OCONTINENTAL · CDH SeriesAlso listed as CDHAMBB-36-O | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.00 | 10.7 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 215213728 | Non-ducted, 2.5–3 tons | 78.3 | 76.0 | 80.6 | 76.0 |
| 5CDHAMB-27-OCONTINENTAL · CDH Series | 2.5 tons28,000 Btu/h · Ducted | 96% | 2.00 | 9.5 | 19.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 215213723 | Ducted, 2.5–3 tons | 77.4 | 72.7 | 82.1 | 72.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CDHAS22B-12-OAlso listed as CDHAS22BA-12-O | 2.36 | Non-ducted, up to 1.5 tons | 95% | 215213711 |
| Capacity retention at 5°F | CDHAS26B-24-O | 113% | Non-ducted, up to 1.5 tons | 96% | 215213717 |
| HSPF2 | CDHAS26BA-24-O | 13.5 | Non-ducted, 2 tons | 98% | 215931368 |
| SEER2 | CDHAS26B-09-OAlso listed as CDHAS26BA-09-O | 27.4 | Non-ducted, up to 1.5 tons | 95% | 215213714 |
| EER2 | CDHAS26B-09-OAlso listed as CDHAS26BA-09-O | 15.4 | Non-ducted, up to 1.5 tons | 95% | 215213714 |
| Heating capacity at 5°F | CDHAS26B-24-O | 22,600 Btu/h | Non-ducted, up to 1.5 tons | 99% | 215213717 |
CONTINENTAL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 28.8(50 is the typical model of its size class)WSCHV0018BA1-Cwith ducted air handler WECC24ABA11 of 1 models have all five ratings · AHRI 218461323 |
| Ducted, 2 tons | 76.2(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models qualify · AHRI 218696907 | 68.3(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models have all five ratings · AHRI 218696907 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)NDHAMB-36-O3 of 4 models qualify · AHRI 215213729 | 83.6(50 is the typical model of its size class)NDHAMB-36-O4 of 4 models have all five ratings · AHRI 215213729 |
| Ducted, 3.5–4.5 tons | 63.3(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPCC48ABA13 of 3 models qualify · AHRI 218696915 | 67.1(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPFX48A-C3 of 3 models have all five ratings · AHRI 218696913 |
| Non-ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class)CDHAS26B-18-Owith ductless indoor unit CDHAS26B-18-IAlso listed as CDHAS26BA-18-O11 of 12 models qualify · AHRI 215213716 | 81.9(50 is the typical model of its size class)CDHAMBB-18-O11 of 12 models have all five ratings · AHRI 215931370 |
| Non-ducted, 2 tons | 88.4(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models qualify · AHRI 215931368 | 76.4(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models have all five ratings · AHRI 215931368 |
| Non-ducted, 2.5–3 tons | 78.0(50 is the typical model of its size class)NDHAMB-36-O7 of 8 models qualify · AHRI 215213730 | 78.3(50 is the typical model of its size class)CDHAMB-36-OAlso listed as CDHAMBB-36-O8 of 8 models have all five ratings · AHRI 215213728 |
Newest CONTINENTAL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WSEHV4860BA1-CCONTINENTAL · F Serieswith ducted air handler WPCC60ABA1 | 4.5 tons52,000 Btu/h · Ducted | 1.80 | 89% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 218696916 |
| WSEHV2436BA1-CCONTINENTAL · F Serieswith ducted air handler WPCC36ABA1 | 2.5 tons32,000 Btu/h · Ducted | 1.80 | 82% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 218696910 |
| WSCHV0048BA1-CContinental · WSC Serieswith ducted air handler WECC60ABC1 | 4 tons45,000 Btu/h · Ducted | 1.85 | 85% | 9.0 | 15.2 | XcelES CC | 1 | 218461334 |
| WSCHV0036BA1-CContinental · WSC Serieswith ducted air handler WECC36ABB1 | 3 tons36,000 Btu/h · Ducted | 2.00 | 76% | 8.5 | 14.7 | None | 1 | 218461333 |
| WSCHV0024BA1-CContinental · WSC Serieswith ducted air handler WECC24ABB1 | 2 tons24,000 Btu/h · Ducted | 1.80 | 76% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 2 | 218461332 |
Compare CONTINENTAL
CONTINENTAL includes these brand names as listed in AHRI: CONTINENTAL. Standards are checked against published thresholds; program rules beyond ratings are not checked.