Skip to content

NOVAIR heat pump efficiency: 42 outdoor models compared

NOVAIR has 42 heat pump outdoor models certified with this refrigerant group, in 119 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes NOVAIR makes. NOVAIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
42
AHRI certifications
119
Efficiency index
76%
Typical model vs same-size, same-type peers (55 models)
Meet CEE 2025
97.6%
41 models

How NOVAIR compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
NOVAIR against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of NOVAIR’s own modelsNOVAIR is strongest on SEER2 (its typical model beats 83% of comparable models) and weakest on COP at 5°F (59%).
  • NOVAIR
  • Middle half of its models
  • Other ranked manufacturers
NOVAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile of NOVAIR’s models
RatingBeats comparable modelsRankRaw median
Efficiency index55 models scored76%Not ranked—
COP at 5°F56 models scored59%Not ranked2.00
Capacity retention at 5°F56 models scored75%Not ranked96%
HSPF255 models scored80%Not ranked10.5
SEER256 models scored83%Not ranked24.0
EER256 models scored81%Not ranked13.0
Heating capacity at 5°F56 models scored71%Not ranked20,200 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
NOVAIR’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • NOVAIR (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1077%72%87%79%
Ducted, 2 tons268%60%71%82%
Ducted, 2.5–3 tons475%47%91%73%
Ducted, 3.5–4.5 tons480%54%89%83%
Non-ducted, up to 1.5 tons1978%62%83%84%
Non-ducted, 2 tons373%70%87%67%
Non-ducted, 2.5–3 tons978%53%69%93%
Non-ducted, 3.5–4.5 tons568%40%57%86%

Every NOVAIR model in the market

NOVAIR’s 56 models with a known size and duct type, over the shape of the whole catalog.
NOVAIR models by size and ratingColoured: NOVAIR · grey shapes: all 14,508 models · lines: catalog medians by size
  • NOVAIR models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 56 novair models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top NOVAIR models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 NOVAIR cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1LEA06SZ36-ONOVAIR · LEA Serieswith ductless indoor unit 4LEA06USK-I0.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.5CEE 25CEE 26CEE AdvXcelDOEES CC3217606280Non-ducted, up to 1.5 tons96.7
2LEA06SZ36-ONOVAIR · LEA Serieswith ducted air handler LEA06DUCT-I0.5 tons6,500 Btu/h · Ducted98%2.4113.87,80021.4CEE 25CEE 26XcelES CC3217606302Ducted, up to 1.5 tons93.5
3LEA09SZ26-ONOVAIR · LEA Serieswith ductless indoor unit LEA09CONSK-I1 ton9,000 Btu/h · Non-ducted96%2.2713.98,60026.0CEE 25CEE 26XcelES CC5217606316Non-ducted, up to 1.5 tons89.5
4LEA24SZ36-ONOVAIR · LEA Serieswith ductless indoor unit LEA24CASS-I2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC3217606301Non-ducted, 2 tons89.4
5LEA06HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA06HH-SK-I0.5 tons6,000 Btu/h · Non-ducted150%2.0015.613,50035.0CEE 25CEE 26XcelES CC1218788019Non-ducted, up to 1.5 tons87.6

All-around best

Top 5 NOVAIR models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1LEA06SZ36-ONOVAIR · LEA Serieswith ductless indoor unit 4LEA06USK-I0.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.518.0CEE 25CEE 26CEE AdvXcelDOEES CC3217606280Non-ducted, up to 1.5 tons96.296.795.796.7
2LEA06SZ36-ONOVAIR · LEA Serieswith ducted air handler LEA06DUCT-I0.5 tons6,500 Btu/h · Ducted98%2.4113.821.414.4CEE 25CEE 26XcelES CC3217606302Ducted, up to 1.5 tons95.093.596.593.5
3LEA06HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA06HH-SK-I0.5 tons6,000 Btu/h · Non-ducted150%2.0015.635.017.4CEE 25CEE 26XcelES CC1218788019Non-ducted, up to 1.5 tons93.487.699.287.6
4LEA09SZ26-ONOVAIR · LEA Serieswith ductless indoor unit LEA09CONSK-I1 ton9,000 Btu/h · Non-ducted96%2.2713.926.016.2CEE 25CEE 26XcelES CC5217606316Non-ducted, up to 1.5 tons92.689.595.789.5
5LEA09HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA09HH-SK-I1 ton9,000 Btu/h · Non-ducted113%2.0014.633.317.0CEE 25CEE 26XcelES CC1218788020Non-ducted, up to 1.5 tons92.385.998.785.9

Best model on each rating

NOVAIR’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FLEA12SZ26-O2.51Non-ducted, up to 1.5 tons99%217606317
Capacity retention at 5°FLEA06HH-SK-O150%Non-ducted, up to 1.5 tons100%218788019
HSPF2LEA06HH-SK-O15.6Non-ducted, up to 1.5 tons100%218788019
SEER2LEA06HH-SK-O35.0Non-ducted, up to 1.5 tons100%218788019
EER2LEA06SZ36-O18.0Non-ducted, up to 1.5 tons99%217606280
Heating capacity at 5°FLEA18HH-SK-O22,600 Btu/hNon-ducted, up to 1.5 tons99%218788022

All 42 NOVAIR models in Explore

NOVAIR size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
NOVAIR: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class)LEA06SZ36-Owith ducted air handler LEA06DUCT-I10 of 10 models qualify · AHRI 21760630295.0(50 is the typical model of its size class)LEA06SZ36-Owith ducted air handler LEA06DUCT-I10 of 10 models have all five ratings · AHRI 217606302
Ducted, 2 tons75.8(50 is the typical model of its size class)LEA24CEN36-Owith ducted air handler LEA24HH-CEN-I2 of 2 models qualify · AHRI 21878802471.7(50 is the typical model of its size class)LEA24CEN36-Owith ducted air handler LEA24HH-CEN-I2 of 2 models have all five ratings · AHRI 218788024
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)LEA36MZ5P36-O4 of 4 models qualify · AHRI 21760626683.6(50 is the typical model of its size class)LEA36MZ5P36-O4 of 4 models have all five ratings · AHRI 217606266
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)LEA48MZ6P36-O4 of 4 models qualify · AHRI 21760626983.9(50 is the typical model of its size class)LEA48MZ6P36-O4 of 4 models have all five ratings · AHRI 217606269
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)LEA06SZ36-Owith ductless indoor unit 4LEA06USK-I18 of 19 models qualify · AHRI 21760628096.2(50 is the typical model of its size class)LEA06SZ36-Owith ductless indoor unit 4LEA06USK-I18 of 19 models have all five ratings · AHRI 217606280
Non-ducted, 2 tons89.4(50 is the typical model of its size class)LEA24SZ36-Owith ductless indoor unit LEA24CASS-I3 of 3 models qualify · AHRI 21760630186.8(50 is the typical model of its size class)LEA24SZ26-Owith ductless indoor unit 4LEA24USK-I3 of 3 models have all five ratings · AHRI 217606297
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class)LEA36MZ5P36-O9 of 9 models qualify · AHRI 21760626783.1(50 is the typical model of its size class)LEA28MZ-4P-454-O*Also listed as LEA27-MZ-LCT- 454-O9 of 9 models have all five ratings · AHRI 218372843
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)LEA48MZ6P36-O5 of 5 models qualify · AHRI 21760627075.6(50 is the typical model of its size class)LEA48MZ6P36-O5 of 5 models have all five ratings · AHRI 217606268

All-around board, every manufacturer

Newest NOVAIR certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified NOVAIR outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
LEA18CEN36-ONOVAIR · LEA Serieswith indoor coil LEA-18/24ACOIL14.5*21*18 and furnace C45-2-V1.5 tons18,000 Btu/h · Ducted1.90100%9.516.6CEE 25CEE 26CEE AdvXcelDOEES CC6218799858
LEA60CEN36-ONOVAIR · LEA Serieswith indoor coil LEA-48/60ACOIL21*21*28 and furnace C120-M-V4.5 tons52,000 Btu/h · Ducted1.8079%8.515.7CEE 25CEE 26XcelES CC6218799857
LEA48CEN36-ONOVAIR · LEA Serieswith indoor coil LEA-48/60ACOIL21*21*28 and furnace C120-M-V4 tons45,000 Btu/h · Ducted1.7589%8.515.2CEE 25CEE 26XcelES CC5218799855
LEA36CEN36-ONOVAIR · LEA Serieswith indoor coil LEA-30/36ACOIL21*21*24 and furnace C120-M-V3 tons35,000 Btu/h · Ducted1.9089%9.315.2CEE 25CEE 26XcelES CC8218799854
LEA30CEN36-ONOVAIR · LEA Serieswith indoor coil LEA-30/36ACOIL17.5*21*24 and furnace C60-2-V2.5 tons29,000 Btu/h · Ducted1.7597%8.515.5CEE 25CEE 26XcelES CC6218799851

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare NOVAIR

Manufacturers of a similar size, side by side.

NOVAIR includes these brand names as listed in AHRI: NOVAIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.