Measured against models of the same size and duct type, NOVAIR scores higher on 5 of the 6 ratings. Breeze33 has 45 outdoor models, NOVAIR has 44 outdoor models. NOVAIR has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Breeze33 and NOVAIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NOVAIR scores higher on 5 of the 6 ratings.
  • Breeze33
  • NOVAIR
  • Other ranked manufacturers
Breeze33NOVAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBreeze33NOVAIR
Efficiency index63%median — · 3rd ranked77%median —
COP at 5°F63% (higher)median 2.10 · 5th ranked59% (higher)median 2.00
Capacity retention at 5°F58%median 71% · 8th ranked77%median 96%
HSPF267%median 9.5 · 4th ranked80%median 10.5
SEER258%median 18.0 · 10th ranked84%median 24.0
EER268%median 12.0 · 2nd ranked82%median 13.0
Heating capacity at 5°F60%median 20,000 Btu/h · 9th ranked72%median 19,800 Btu/h
Outdoor models4544
AHRI certifications1,260121

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBreeze33NOVAIR
CEE 2025 Tier 1 (Split ASHP)66.7%30 models97.7%43 models
CEE 2026 Tier 1 (Split ASHP)64.4%29 models97.7%43 models
CEE Advanced Tier (Split ASHP)4.4%2 models4.5%2 models
Xcel Energy Colorado cold-climate ASHP (2025)57.8%26 models100%44 models
DOE Cold Climate Heat Pump Challenge4.4%2 models4.5%2 models
ENERGY STAR Cold Climate55.6%25 models100%44 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Breeze33
  • NOVAIR
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBreeze33NOVAIR
Ducted, up to 1.5 tons9 · index 66%10 · index 78%
Ducted, 2 tons5 · index 61%2 · index 68%
Ducted, 2.5 to 3 tons10 · index 67%4 · index 76%
Ducted, 3.5 to 4.5 tons12 · index 68%4 · index 80%
Ducted, 5 tons and up1 · index 60%None
Non-ducted, up to 1.5 tons9 · index 63%21 · index 79%
Non-ducted, 2 tons2 · index 56%3 · index 75%
Non-ducted, 2.5 to 3 tons8 · index 54%9 · index 78%
Non-ducted, 3.5 to 4.5 tons5 · index 54%5 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBreeze33Cold-climate score, best modelNOVAIRCold-climate score, best model
Ducted, up to 1.5 tons85.8(50 is the typical model of its size class)BZ33-INV18OUT2-454-G3-Jwith ducted air handler BZ33-AHU18-454-G3-J6 of 9 models qualify · AHRI 21544974493.7(50 is the typical model of its size class) (higher)LEA06SZ36-Owith ducted air handler LEA06DUCT-I10 of 10 models qualify · AHRI 217606302
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)BZ33-HYP24OUT2-454-G3-Pwith ducted air handler BZ33-DIDU24-454-G3-P4 of 6 models qualify · AHRI 21544977575.7(50 is the typical model of its size class)LEA24CEN36-Owith ducted air handler LEA24HH-CEN-I2 of 2 models qualify · AHRI 218788024
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)BZ33-HYP36OUT2-454-G3-Pwith ducted air handler BZ33-DIDU36-454-G3-P6 of 9 models qualify · AHRI 21544977682.7(50 is the typical model of its size class)LEA36MZ5P36-O4 of 4 models qualify · AHRI 217606266
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P7 of 12 models qualify · AHRI 21544980982.6(50 is the typical model of its size class)LEA48MZ6P36-O4 of 4 models qualify · AHRI 217606269
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class)BZ33-HYP06OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP06WALL2-454-G3-P6 of 9 models qualify · AHRI 21544975797.0(50 is the typical model of its size class)LEA06SZ36-Owith ductless indoor unit 4LEA06USK-I20 of 21 models qualify · AHRI 217606280
Non-ducted, 2 tons90.1(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ductless indoor unit BZ33-CASS24-454-G3-P2 of 2 models qualify · AHRI 21544976690.1(50 is the typical model of its size class)LEA24SZ36-Owith ductless indoor unit LEA24CASS-I3 of 3 models qualify · AHRI 217606301
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)BZ33-HYP36OUT2-454-G3-Pwith ductless indoor unit BZ33-IFCM36-454-G3-P6 of 8 models qualify · AHRI 21544978478.3(50 is the typical model of its size class)LEA36MZ5P36-O9 of 9 models qualify · AHRI 217606267
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P5 of 5 models qualify · AHRI 21544981073.6(50 is the typical model of its size class)LEA48MZ6P36-O5 of 5 models qualify · AHRI 217606270

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBreeze33All-around score, best modelNOVAIRAll-around score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class)BZ33-HYP09OUT2-454-G3-Pwith ducted air handler BZ33-DIDU9-454-G3-P8 of 8 models have all five ratings · AHRI 21544977295.0(50 is the typical model of its size class) (higher)LEA06SZ36-Owith ducted air handler LEA06DUCT-I10 of 10 models have all five ratings · AHRI 217606302
Ducted, 2 tons78.6(50 is the typical model of its size class) (higher)BZ33-HYP24OUT2-454-G3-Pwith ducted air handler BZ33-DIDU24-454-G3-P7 of 7 models have all five ratings · AHRI 21544977571.6(50 is the typical model of its size class)LEA24CEN36-Owith ducted air handler LEA24HH-CEN-I2 of 2 models have all five ratings · AHRI 218788024
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)BZ33-HYP365Z2-454-G3-P9 of 9 models have all five ratings · AHRI 21544980683.9(50 is the typical model of its size class)LEA36MZ5P36-O4 of 4 models have all five ratings · AHRI 217606266
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)BZ33-HP486Z2-454-G3-P12 of 12 models have all five ratings · AHRI 21544979784.3(50 is the typical model of its size class)LEA48MZ6P36-O4 of 4 models have all five ratings · AHRI 217606269
Ducted, 5 tons and up67.2(50 is the typical model of its size class)7HP14F60P-**Awith ducted air handler 7AH1AV60PX-1 of 1 models have all five ratings · AHRI 215792805No models in this size class
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class)BZ33-HYP06OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP06WALL2-454-G3-P9 of 9 models have all five ratings · AHRI 21544975796.6(50 is the typical model of its size class)LEA06SZ36-Owith ductless indoor unit 4LEA06USK-I20 of 21 models have all five ratings · AHRI 217606280
Non-ducted, 2 tons78.3(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP24WALL2-454-G3-P2 of 2 models have all five ratings · AHRI 21544976187.8(50 is the typical model of its size class) (higher)LEA24SZ26-Owith ductless indoor unit 4LEA24USK-I3 of 3 models have all five ratings · AHRI 217606297
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)BZ33-HYP365Z2-454-G3-P8 of 8 models have all five ratings · AHRI 21544980583.4(50 is the typical model of its size class) (higher)LEA28MZ-4P-454-O*Also listed as LEA27-MZ-LCT- 454-O9 of 9 models have all five ratings · AHRI 218372843
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P5 of 5 models have all five ratings · AHRI 21544980875.5(50 is the typical model of its size class)LEA48MZ6P36-O5 of 5 models have all five ratings · AHRI 217606268

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBreeze33NOVAIR
COP at 5°Fbeats 97% · 2.40BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 99% · 2.51LEA12SZ26-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 126%BZ33-HYP09OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 100% · 150%LEA06HH-SK-ONon-ducted, up to 1.5 tons
HSPF2beats 99% · 14.8BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 100% · 15.6LEA06HH-SK-ONon-ducted, up to 1.5 tons
SEER2beats 97% · 25.0BZ33-HP274Z2-454-G3-PNon-ducted, 2.5 to 3 tonsbeats 100% · 35.0LEA06HH-SK-ONon-ducted, up to 1.5 tons
EER2beats 99% · 18.0BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 99% · 18.0LEA06SZ36-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 39,500 Btu/hBZ33-HYP36OUT2-454-G3-PNon-ducted, 2.5 to 3 tonsbeats 99% · 22,600 Btu/hLEA18HH-SK-ONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Breeze33 vs NOVAIR: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Breeze33 (median, middle 50%)
  • NOVAIR (median, middle 50%)
Heating capacity, % of its 47°F maximum71%74%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Breeze33: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Breeze33, 47°F32100%100%100%100%100%
Breeze33, 17°F3268%73%79%82%88%
Breeze33, 5°F3259%64%71%82%89%
Breeze33: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Breeze33, 47°F322.943.13.253.473.58
Breeze33, 17°F322.092.142.332.542.66
Breeze33, 5°F321.891.9822.142.25
NOVAIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
NOVAIR, 47°F36100%100%100%100%100%
NOVAIR, 17°F3670%74%82%85%91%
NOVAIR, 5°F3664%69%74%79%85%
NOVAIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
NOVAIR, 47°F362.863.13.313.583.83
NOVAIR, 17°F362.022.132.32.482.55
NOVAIR, 5°F361.81.9522.132.36

Source: NEEP ccASHP list · as of