Skip to content

Breeze33 vs Kepler heat pumps

Measured against models of the same size and duct type, Kepler scores higher on 4 of the 6 ratings. Breeze33 has 45 outdoor models, Kepler has 45 outdoor models. Kepler has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Breeze33 and Kepler on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Kepler scores higher on 4 of the 6 ratings.
  • Breeze33
  • Kepler
  • Other ranked manufacturers
Breeze33Kepler

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBreeze33Kepler
Efficiency index63%median — · 3rd ranked63%median —
COP at 5°F63% (higher)median 2.10 · 5th ranked59% (higher)median 2.00
Capacity retention at 5°F58%median 71% · 8th ranked63%median 81%
HSPF267%median 9.5 · 4th ranked74%median 9.7
SEER258%median 18.0 · 10th ranked65%median 20.0
EER268% (higher)median 12.0 · 2nd ranked58% (higher)median 11.7
Heating capacity at 5°F60%median 20,000 Btu/h · 9th ranked65%median 21,600 Btu/h
Outdoor models4545
AHRI certifications1,260169

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBreeze33Kepler
CEE 2025 Tier 1 (Split ASHP)66.7%30 models86.7%39 models
CEE 2026 Tier 1 (Split ASHP)64.4%29 models84.4%38 models
CEE Advanced Tier (Split ASHP)4.4%2 models2.2%1 models
Xcel Energy Colorado cold-climate ASHP (2025)57.8%26 models80%36 models
DOE Cold Climate Heat Pump Challenge4.4%2 models2.2%1 models
ENERGY STAR Cold Climate55.6%25 models75.6%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Breeze33
  • Kepler
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBreeze33Kepler
Ducted, up to 1.5 tons9 · index 66%11 · index 75%
Ducted, 2 tons5 · index 61%5 · index 67%
Ducted, 2.5 to 3 tons10 · index 67%9 · index 60%
Ducted, 3.5 to 4.5 tons12 · index 68%10 · index 59%
Ducted, 5 tons and up1 · index 60%1 · index 63%
Non-ducted, up to 1.5 tons9 · index 63%14 · index 64%
Non-ducted, 2 tons2 · index 56%3 · index 67%
Non-ducted, 2.5 to 3 tons8 · index 54%8 · index 53%
Non-ducted, 3.5 to 4.5 tons5 · index 55%4 · index 60%
Non-ducted, 5 tons and upNone1 · index 59%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBreeze33Cold-climate score, best modelKeplerCold-climate score, best model
Ducted, up to 1.5 tons85.8(50 is the typical model of its size class)BZ33-INV18OUT2-454-G3-Jwith ducted air handler BZ33-AHU18-454-G3-J6 of 9 models qualify · AHRI 21544974493.7(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D10 of 11 models qualify · AHRI 218857674
Ducted, 2 tons85.8(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ducted air handler BZ33-DIDU24-454-G3-P4 of 6 models qualify · AHRI 21544977585.8(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models qualify · AHRI 218857661
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)BZ33-HYP36OUT2-454-G3-Pwith ducted air handler BZ33-DIDU36-454-G3-P6 of 9 models qualify · AHRI 21544977683.5(50 is the typical model of its size class)ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-D8 of 9 models qualify · AHRI 218856688
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P7 of 12 models qualify · AHRI 21544980982.6(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D10 of 10 models qualify · AHRI 218853768
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class)BZ33-HYP06OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP06WALL2-454-G3-P6 of 9 models qualify · AHRI 21544975797.0(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D11 of 14 models qualify · AHRI 218851004
Non-ducted, 2 tons90.1(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ductless indoor unit BZ33-CASS24-454-G3-P2 of 2 models qualify · AHRI 21544976690.1(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ductless indoor unit IDUMCD-24HRFN10-M1-D3 of 3 models qualify · AHRI 218857649
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)BZ33-HYP36OUT2-454-G3-Pwith ductless indoor unit BZ33-IFCM36-454-G3-P6 of 8 models qualify · AHRI 21544978478.3(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D6 of 8 models qualify · AHRI 218853766
Non-ducted, 3.5 to 4.5 tons73.7(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P5 of 5 models qualify · AHRI 21544981073.7(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models qualify · AHRI 218853769
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBreeze33All-around score, best modelKeplerAll-around score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class)BZ33-HYP09OUT2-454-G3-Pwith ducted air handler BZ33-DIDU9-454-G3-P8 of 8 models have all five ratings · AHRI 21544977295.0(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D11 of 11 models have all five ratings · AHRI 218857674
Ducted, 2 tons78.6(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ducted air handler BZ33-DIDU24-454-G3-P7 of 7 models have all five ratings · AHRI 21544977578.9(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1with ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models have all five ratings · AHRI 218857656
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)BZ33-HYP365Z2-454-G3-P9 of 9 models have all five ratings · AHRI 21544980683.9(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D9 of 9 models have all five ratings · AHRI 218853765
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)BZ33-HP486Z2-454-G3-P12 of 12 models have all five ratings · AHRI 21544979785.3(50 is the typical model of its size class)ODUM6OE30-48HFN10-M1D-D10 of 10 models have all five ratings · AHRI 218853753
Ducted, 5 tons and up67.2(50 is the typical model of its size class) (higher)7HP14F60P-**Awith ducted air handler 7AH1AV60PX-1 of 1 models have all five ratings · AHRI 21579280563.2(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853756
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class)BZ33-HYP06OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP06WALL2-454-G3-P9 of 9 models have all five ratings · AHRI 21544975796.6(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D14 of 14 models have all five ratings · AHRI 218851004
Non-ducted, 2 tons78.3(50 is the typical model of its size class)BZ33-HYP24OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP24WALL2-454-G3-P2 of 2 models have all five ratings · AHRI 21544976187.8(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1with ductless indoor unit IDUMSEPD-24HRFN10-M1-D3 of 3 models have all five ratings · AHRI 218851003
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)BZ33-HYP365Z2-454-G3-P8 of 8 models have all five ratings · AHRI 21544980578.8(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D8 of 8 models have all five ratings · AHRI 218853764
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class)BZ33-HYP486Z2-454-G3-P5 of 5 models have all five ratings · AHRI 21544980875.5(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models have all five ratings · AHRI 218853767
Non-ducted, 5 tons and upNo models in this size class59.0(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853755

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBreeze33Kepler
COP at 5°Fbeats 97% · 2.40BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 99% · 2.51ODUMOX230-12HFN10-M1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 126%BZ33-HYP09OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 98% · 126%ODUMOX330-09HFN10-M1XNon-ducted, up to 1.5 tons
HSPF2beats 99% · 14.8BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 99% · 14.8ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons
SEER2beats 97% · 25.0BZ33-HP274Z2-454-G3-PNon-ducted, 2.5 to 3 tonsbeats 97% · 25.0ODUM4OD30-27HFN10-M1D-DNon-ducted, 2.5 to 3 tons
EER2beats 99% · 18.0BZ33-HYP06OUT2-454-G3-PNon-ducted, up to 1.5 tonsbeats 99% · 18.0ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 39,500 Btu/hBZ33-HYP36OUT2-454-G3-PNon-ducted, 2.5 to 3 tonsbeats 98% · 39,000 Btu/hODUMOX630-36HFN10-M3XDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Breeze33 vs Kepler: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Breeze33 (median, middle 50%)
  • Kepler (median, middle 50%)
Heating capacity, % of its 47°F maximum71%71%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
Breeze33: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Breeze33, 47°F32100%100%100%100%100%
Breeze33, 17°F3268%73%79%82%88%
Breeze33, 5°F3259%64%71%82%89%
Breeze33: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Breeze33, 47°F322.943.13.253.473.58
Breeze33, 17°F322.092.142.332.542.66
Breeze33, 5°F321.891.9822.142.25
Kepler: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F45100%100%100%100%100%
Kepler, 17°F4569%73%76%81%86%
Kepler, 5°F4559%64%71%79%82%
Kepler: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F452.843.063.23.463.72
Kepler, 17°F4522.142.322.512.61
Kepler, 5°F451.851.922.12.36

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter