Both views use the same certified data. This device remembers your choice.
Breeze33 vs Kepler: heat pump ratings compared
Against heat pumps of the same size and type, a typical Breeze33 model beats 63% and a typical Kepler model 63%. They are level.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Breeze33
63%
of similar heat pumps beaten by its typical model
Well above average45 models listed
Kepler
63%
of similar heat pumps beaten by its typical model
Well above average45 models listed
- Efficiency on a 5°F dayCOP at 5°FBreeze33: Beats 63%Kepler: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBreeze33: Beats 58%Kepler: Beats 63%
- Winter-long heating efficiencyHSPF2Breeze33: Beats 67%Kepler: Beats 74%
- Summer-long cooling efficiencySEER2Breeze33: Beats 58%Kepler: Beats 65%
- Hot-day cooling efficiencyEER2Breeze33: Beats 68%Kepler: Beats 58%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Breeze33
- 67%
- Kepler
- 87%
Xcel CC
- Breeze33
- 58%
- Kepler
- 80%
CEE Advanced
- Breeze33
- 4%
- Kepler
- 2%
ENERGY STAR CC
- Breeze33
- 56%
- Kepler
- 76%
Top cold-climate picks, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
Breeze33
- 1BZ33-HYP36OUT2-454-G3-Pwith ducted air handler BZ33-DIDU36-454-G3-PBreeze333 tons · 36,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
- 2BZ33-HYP365Z2-454-G3-PBreeze333 tons · 36,000 Btu/h · DuctedKeeps 106% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
- 3BZ33-INV30OUT2-454-G3-Jwith ducted air handler BZ33-AHU30-454-G3-JBreeze332.5 tons · 30,000 Btu/h · DuctedKeeps 101% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 101% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.97 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.8 (HSPF2)
- Top 10%
Kepler
- 1ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-DKepler3 tons · 36,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
- 2ODUM5OX631-36HFN10-M1XD-DKepler3 tons · 36,000 Btu/h · DuctedKeeps 106% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
- 3ODUM4OD31-27HFN10-M1XD-DKepler2.5 tons · 28,000 Btu/h · DuctedKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.