- Insights
- Rebate standards
Both views use the same certified data. This device remembers your choice.
Which heat pumps meet rebate efficiency standards?
Rebate and tax programs often require a heat pump to meet a published efficiency level: a CEE tier, the DOE cold-climate challenge, Xcel’s cold-climate rebate or the ENERGY STAR cold-climate label.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
- CEE 2025Many utility rebate programs57%
- CEE 2026Utility programs updating to the 2026 level56%
- CEE AdvancedCold-climate programs (same bar as the DOE challenge)2.5%
- Xcel CCXcel Energy Colorado’s cold-climate rebate53%
- DOE CCHPU.S. Department of Energy cold-climate challenge2.5%
- ENERGY STAR CCThe ENERGY STAR cold-climate label41%
CEE 2025 Tier 1: 57%
Out of 13,514 models. A model counts when at least one of its certified pairings meets every requirement on its own. Source: AHRI directory, ENERGY STAR.
What each level asks for
Many utility rebate programs
CEE 2025 Tier 1 (Split ASHP)
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough.
57% of modelsWhich models meet it
Utility programs updating to the 2026 level
CEE 2026 Tier 1 (Split ASHP)
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough.
56% of modelsWhich models meet it
Cold-climate programs (same bar as the DOE challenge)
CEE Advanced Tier (Split ASHP)
- Efficiency on a 5°F day (COP at 5°F): 2.1 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 100% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
2.5% of modelsWhich models meet it
Xcel Energy Colorado’s cold-climate rebate
Xcel Energy Colorado cold-climate ASHP (2025)
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
53% of modelsWhich models meet it
U.S. Department of Energy cold-climate challenge
DOE Cold Climate Heat Pump Challenge
- Efficiency on a 5°F day (COP at 5°F): 2.1 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 100% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
2.5% of modelsWhich models meet it
The ENERGY STAR cold-climate label
ENERGY STAR Cold Climate
A listing, not a set of numbers: the model must carry ENERGY STAR’s cold-climate designation.
41% of modelsWhich models meet it
Only ratings are checked. Programs can also set rules on the installer, sizing and paperwork.
Next steps
Advanced view: exact criteria tables, pass rates by size and duct type, how models move through the tiers, what keeps models out.
Open the advanced view