CEE Advanced: which heat pumps meet it?
CEE’s cold-climate tier: full rated capacity and a COP of at least 2.1 at 5°F, with HSPF2 of at least 8.5. 2.5% of certified models (336, about 1 in 40) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Advanced
- Efficiency on a 5°F day (COP at 5°F): 2.1 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 100% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency
- Up to 1.5 tons178 of 5,384 models3%
- 2 tons39 of 1,920 models2%
- 2.5 to 3 tons61 of 2,923 models2%
- 3.5 to 4.5 tons56 of 2,812 models2%
- 5 tons and up2 of 475 models0%
All sizes: 2.5%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
- 1HH836E2S11with indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1York3 tons · 33,200 Btu/h · DuctedTop 10%3.08
- 2RD18AY36AJVCwith ducted air handler C(A,C,D,E)36B3J+TDRRheem2.5 tons · 28,600 Btu/h · DuctedTop 10%2.91
- 3RD18AY48AJVCwith ducted air handler D(A,C,E)60D3J+TDRRheem3 tons · 37,600 Btu/h · DuctedTop 10%2.88
- 45TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCBTrane2.5 tons · 29,800 Btu/h · DuctedTop 10%2.85
- 5SL22KLV-036-230A**with indoor coil D(A,C,E)37D4J+TDR and furnace SLP99UH090XV48CLennox2.5 tons · 32,600 Btu/h · DuctedTop 10%2.76
- 6BOHA-36MTB-M18Swith indoor coil D(A,C,E)37D3J+TDR and furnace BGH97M080B3ABosch2.5 tons · 31,600 Btu/h · DuctedTop 10%2.61
- 7PAS-30BUFASDQ1with ductless indoor unit PPFC-B30UFA1DQHITACHI2.5 tons · 30,000 Btu/h · DuctlessTop 10%2.50
- 8YPAS30BUFASDQ1with ductless indoor unit YPPFCB30UFA1DQYork2.5 tons · 30,000 Btu/h · DuctlessTop 10%2.50
- 9MOE30-36HFN10-M3Xwith ducted air handler MVBDM-36HWFN10-WC3Midea (sold as MDV)3 tons · 36,000 Btu/h · DuctedTop 10%2.46
- 10CHV6-RS36URBMHHCooper&Hunter (sold as Cooper & Hunter)3 tons · 36,000 Btu/h · DuctlessTop 10%2.45
61 ducted, 2.5 to 3 tons models meet it. See them all in the advanced list