Skip to content

New heat pump models

Since 2025, new heat pumps are made with R-454B or R-32 refrigerant instead of R-410A, which is being phased down.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

The refrigerant switchIn the newest certifications, R-410A is down to 0%, from 94% in the oldest still listed.

Each bar: 500,000 AHRI certifications in a row. AHRI numbers rise over time, so they stand in for dates, which AHRI does not publish. Source: AHRI directory.

What the switch means

R-454B and R-32 warm the planet far less than R-410A if they leak. Heat pumps already installed with R-410A can still be serviced; the phase-down limits how much new R-410A is made. The two kinds use different parts.

Newest models: ducted, 2.5 to 3 tons

By AHRI reference number, newest first.

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

  1. 1D5CURAH30AAK+KSAIC0701230with indoor coil (H,G)G32*36+TXV and furnace *97VTN1002122ACarrier (sold as Tempstar)2.5 tons · 29,200 Btu/h · DuctedGood1.70
  2. 2D5CURAH36AAK+KSAIC0701230with indoor coil (H,G)G32*36+TXV and furnace *97VTN1002122ACarrier (sold as Tempstar)3 tons · 36,000 Btu/h · DuctedTop 10%1.80
  3. 3D5CUHAH36AAK+KSAIC0701230with indoor coil (H,G)G32*36+TXV and furnace *97VTN1002122ACarrier (sold as Tempstar)3 tons · 33,600 Btu/h · DuctedBelow the middle1.75
  4. 4D5CUHAH30AAK+KSAIC0701230with indoor coil (H,G)G32*36+TXV and furnace *97VTN1002122ACarrier (sold as Tempstar)2.5 tons · 28,600 Btu/h · DuctedGood1.80
  5. 5MSHMB36R2AN*with ducted air handler MTHHA36R4ASMOOVAIR3 tons · 36,000 Btu/h · DuctedBelow the middle1.90
  6. 6MSHMA30R2AN*with ducted air handler MTHHA30R4ASMOOVAIR2.5 tons · 30,000 Btu/h · DuctedBelow the middle1.97
  7. 7S36TCP2Cwith ducted air handler S36AUPDAStar Air Kontrol3 tons · 36,000 Btu/h · DuctedBelow the middle1.90
  8. 837MURAQ36AA3+KSAIC0701230with indoor coil (H,P)G35*36+TXV and furnace 59SU5B100M21**20Carrier3 tons · 36,600 Btu/h · DuctedTop 10%1.92
  9. 937MURAQ30AA3+KSAIC0701230with indoor coil (H,P)G35*36+TXV and furnace 59TP7A100V21**22Carrier2.5 tons · 30,200 Btu/h · DuctedGood1.70

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: every reference band of the switch, the full list of newest certifications.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter