Skip to content

CEE 2025: which heat pumps meet it?

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs. 57% of certified models (7,762, about 6 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 60% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 45% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,346 of 5,405 models62%
  • 2 tons1,303 of 1,934 models67%
  • 2.5 to 3 tons1,675 of 2,930 models57%
  • 3.5 to 4.5 tons1,286 of 2,822 models46%
  • 5 tons and up152 of 475 models32%

All sizes: 57%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

  1. 17HP14F30P-**Awith indoor coil D(A,C,E)37A3K+TDR and furnace 97G2UH110CE20Lennox (sold as Concord)2.5 tons · 27,400 Btu/h · DuctedTop 10%4.06
  2. 2NS21H36MA5-**Awith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances (sold as GE)2.5 tons · 31,400 Btu/h · DuctedTop 10%4.00
  3. 35A6H5036A1with indoor coil DH36T4J and furnace S9V2C100U5PSCTrane (sold as American Standard)3 tons · 33,600 Btu/h · DuctedTop 10%3.19
  4. 4KUSXA422Awith ducted air handler D(A,C,E)42B4D+TDRLG3 tons · 37,600 Btu/h · DuctedTop 10%3.16
  5. 5KUSXB421Awith ducted air handler D(A,C,E)48D3D+TDRLG3 tons · 38,500 Btu/h · DuctedTop 10%3.11
  6. 6HH836E2S12with indoor coil D(A,C,E)37E3K+TDR and furnace Z8ET100C20LMPS1York (sold as Coleman)2.5 tons · 32,000 Btu/h · DuctedTop 10%3.10
  7. 75TWR5036A1with indoor coil DH60T4J and furnace S8V2B080M4PCBTrane3 tons · 33,200 Btu/h · DuctedTop 10%3.08
  8. 8HH836E2S11with indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1York3 tons · 33,200 Btu/h · DuctedTop 10%3.08
  9. 9XH536E2S11with indoor coil D(A,C,E)36B4K+TDR and furnace Z8ET120C20LMPS1York (sold as Champion Heating and Cooling)2.5 tons · 32,800 Btu/h · DuctedTop 10%3.08
  10. 10RP15AY42AJ2Nwith ducted air handler AE*L+CM59A4J+TDRRheem (sold as RUUD)3 tons · 37,600 Btu/h · DuctedTop 10%3.06

1,346 ducted, 2.5 to 3 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.