Skip to content

Kepler heat pump efficiency: 45 outdoor models compared

Kepler has 45 heat pump outdoor models certified with this refrigerant group, in 169 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Kepler makes. Kepler has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
45
AHRI certifications
169
Efficiency index
63%
Typical model vs same-size, same-type peers (66 models)
Meet CEE 2025
86.7%
39 models

How Kepler compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Kepler against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Kepler’s own modelsKepler is strongest on HSPF2 (its typical model beats 74% of comparable models) and weakest on EER2 (58%).
  • Kepler
  • Middle half of its models
  • Other ranked manufacturers
Kepler

Source: AHRI Directory, NEEP · as of

Average peer percentile of Kepler’s models
RatingBeats comparable modelsRankRaw median
Efficiency index66 models scored63%Not ranked—
COP at 5°F66 models scored59%Not ranked2.00
Capacity retention at 5°F66 models scored63%Not ranked81%
HSPF266 models scored74%Not ranked9.7
SEER266 models scored65%Not ranked20.0
EER266 models scored58%Not ranked11.7
Heating capacity at 5°F66 models scored65%Not ranked21,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Kepler’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Kepler (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1176%76%83%78%
Ducted, 2 tons567%55%82%74%
Ducted, 2.5 to 3 tons960%51%74%61%
Ducted, 3.5 to 4.5 tons1059%47%78%60%
Ducted, 5 tons and up163%67%82%89%
Non-ducted, up to 1.5 tons1464%69%69%64%
Non-ducted, 2 tons367%91%74%52%
Non-ducted, 2.5 to 3 tons853%37%57%57%
Non-ducted, 3.5 to 4.5 tons460%47%81%56%
Non-ducted, 5 tons and up159%79%48%77%

Every Kepler model in the market

Kepler’s 66 models with a known size and duct type, over the shape of the whole catalog.
Kepler models by size and ratingColoured: Kepler · grey shapes: all 15,936 models · lines: catalog medians by size
  • Kepler models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 66 kepler models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Kepler in the cold

From NEEP’s cold-climate listings: 45 Kepler models against all 6,343 listed models.
Kepler capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical Kepler model keeps 71% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • Kepler (median, middle 50%)
Heating capacity, % of its 47°F maximum71%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Kepler: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F45100%100%100%100%100%
Kepler, 17°F4569%73%76%81%86%
Kepler, 5°F4559%64%71%79%82%
Kepler: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F452.843.063.23.463.72
Kepler, 17°F4522.142.322.512.61
Kepler, 5°F451.851.922.12.36

Source: NEEP ccASHP list · as of

Top Kepler models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Kepler cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPB-06HRFN10-M1-D0.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.5CEE 25CEE 26CEE AdvXcelDOEES CC3218851004Non-ducted, up to 1.5 tons97.0
2ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D0.5 tons6,500 Btu/h · Ducted98%2.4113.87,80021.4CEE 25CEE 26Xcel3218857674Ducted, up to 1.5 tons93.7
3ODUMOX230-09HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMFA2M-12HRFN10-M1-D1 ton9,000 Btu/h · Non-ducted96%2.2713.98,60026.0CEE 25CEE 26XcelES CC8218857666Non-ducted, up to 1.5 tons90.4
4ODUMOD30-24HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMCD-24HRFN10-M1-D2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC3218857649Non-ducted, 2 tons90.1
5ODUMOD30-24HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTJ-24HWFN10-M1-D2 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26Xcel3218857661Ducted, 2 tons85.8

All-around best

Top 5 Kepler models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPB-06HRFN10-M1-D0.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.518.0CEE 25CEE 26CEE AdvXcelDOEES CC3218851004Non-ducted, up to 1.5 tons96.697.096.197.0
2ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D0.5 tons6,500 Btu/h · Ducted98%2.4113.821.414.4CEE 25CEE 26Xcel3218857674Ducted, up to 1.5 tons95.193.796.593.7
3ODUMOX230-09HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMFA2M-12HRFN10-M1-D1 ton9,000 Btu/h · Non-ducted96%2.2713.926.016.2CEE 25CEE 26XcelES CC8218857666Non-ducted, up to 1.5 tons93.390.496.290.4
4ODUMOD30-24HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMSEPD-24HRFN10-M1-D2 tons24,000 Btu/h · Non-ducted78%2.5411.723.014.0CEE 25CEE 26XcelES CC3218851003Non-ducted, 2 tons87.885.790.085.7
5ODUMOX330-09HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-09HWFN10-M1-D1 ton9,000 Btu/h · Ducted112%1.8912.521.413.4CEE 25CEE 26Xcel8218857672Ducted, up to 1.5 tons87.180.693.680.6

Best model on each rating

Kepler’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FODUMOX230-12HFN10-M12.51Non-ducted, up to 1.5 tons99%218857654
Capacity retention at 5°FODUMOX330-09HFN10-M1X126%Non-ducted, up to 1.5 tons98%218857676
HSPF2ODUMOX230-06HFN10-M1X14.8Non-ducted, up to 1.5 tons99%218851004
SEER2ODUM4OD30-27HFN10-M1D-D25.0Non-ducted, 2.5 to 3 tons97%218853746
EER2ODUMOX230-06HFN10-M1X18.0Non-ducted, up to 1.5 tons99%218851004
Heating capacity at 5°FODUMOX630-36HFN10-M3X39,000 Btu/hDucted, 2.5 to 3 tons98%218857641

All 45 Kepler models in Explore

Kepler size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Kepler: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D10 of 11 models qualify · AHRI 21885767495.1(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D11 of 11 models have all five ratings · AHRI 218857674
Ducted, 2 tons85.8(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models qualify · AHRI 21885766178.9(50 is the typical model of its size class)ODUMOD30-24HFN10-M1with ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models have all five ratings · AHRI 218857656
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-D8 of 9 models qualify · AHRI 21885668883.9(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D9 of 9 models have all five ratings · AHRI 218853765
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D10 of 10 models qualify · AHRI 21885376885.3(50 is the typical model of its size class)ODUM6OE30-48HFN10-M1D-D10 of 10 models have all five ratings · AHRI 218853753
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)63.2(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853756
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D11 of 14 models qualify · AHRI 21885100496.6(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D14 of 14 models have all five ratings · AHRI 218851004
Non-ducted, 2 tons90.1(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ductless indoor unit IDUMCD-24HRFN10-M1-D3 of 3 models qualify · AHRI 21885764987.8(50 is the typical model of its size class)ODUMOD30-24HFN10-M1with ductless indoor unit IDUMSEPD-24HRFN10-M1-D3 of 3 models have all five ratings · AHRI 218851003
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D6 of 8 models qualify · AHRI 21885376678.8(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D8 of 8 models have all five ratings · AHRI 218853764
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models qualify · AHRI 21885376975.4(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models have all five ratings · AHRI 218853767
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)59.0(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853755

All-around board, every manufacturer

Newest Kepler certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Kepler outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
ODUMOX630-60HFN10-M3Keplerwith ducted air handler IDUMVBM-60D28T6N10-UC4 tons50,000 Btu/h · Ducted1.8078%8.214.3ES CC5218864575
ODUMOX630-48HFN10-M3Keplerwith ducted air handler IDUMVBM-60D28T6N10-UC4 tons45,000 Btu/h · Ducted1.7581%8.014.8CEE 25CEE 26XcelES CC6218864573
ODUMOD30-36HFN10-M3Kepler · ODU Serieswith ducted air handler IDUMVBM-36C24T4N10-UC3 tons36,000 Btu/h · Ducted2.0076%8.514.7CEE 25CEE 26XcelES CC7218864571
ODUMOD30-30HFN10-M3Keplerwith ducted air handler IDUMVBM-36C24T4N10-UC2.5 tons29,000 Btu/h · Ducted1.9063%8.215.8CEE 257218864568
ODUMOX430-24HFN10-M3Kepler · ODU Serieswith ducted air handler IDUMVBM-24B18T3N10-UC2 tons24,000 Btu/h · Ducted1.8076%9.016.0CEE 25CEE 26XcelES CC5218864565

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for Kepler in this group.

Compare Kepler

Manufacturers of a similar size, side by side.

Kepler includes these brand names as listed in AHRI: Kepler. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter