- Insights
- Manufacturers
- Kepler
Both views use the same certified data. This device remembers your choice.
Kepler heat pump efficiency: 45 outdoor models compared
Kepler has 45 heat pump outdoor models certified with this refrigerant group, in 169 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Kepler makes. Kepler has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 45
- AHRI certifications
- 169
- Efficiency index
- 63%
- Typical model vs same-size, same-type peers (66 models)
- Meet CEE 2025
- 86.7%
- 39 models
How Kepler compares with comparable models
- Kepler
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index66 models scored | 63% | Not ranked | — |
| COP at 5°F66 models scored | 59% | Not ranked | 2.00 |
| Capacity retention at 5°F66 models scored | 63% | Not ranked | 81% |
| HSPF266 models scored | 74% | Not ranked | 9.7 |
| SEER266 models scored | 65% | Not ranked | 20.0 |
| EER266 models scored | 58% | Not ranked | 11.7 |
| Heating capacity at 5°F66 models scored | 65% | Not ranked | 21,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 86.7% | 39 |
| CEE 2026 Tier 1 (Split ASHP) | 84.4% | 38 |
| CEE Advanced Tier (Split ASHP) | 2.2% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 80% | 36 |
| DOE Cold Climate Heat Pump Challenge | 2.2% | 1 |
| ENERGY STAR Cold Climate | 75.6% | 34 |
Sizes and duct types offered
- Kepler (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 76% | 76% | 83% | 78% |
| Ducted, 2 tons | 5 | 67% | 55% | 82% | 74% |
| Ducted, 2.5 to 3 tons | 9 | 60% | 51% | 74% | 61% |
| Ducted, 3.5 to 4.5 tons | 10 | 59% | 47% | 78% | 60% |
| Ducted, 5 tons and up | 1 | 63% | 67% | 82% | 89% |
| Non-ducted, up to 1.5 tons | 14 | 64% | 69% | 69% | 64% |
| Non-ducted, 2 tons | 3 | 67% | 91% | 74% | 52% |
| Non-ducted, 2.5 to 3 tons | 8 | 53% | 37% | 57% | 57% |
| Non-ducted, 3.5 to 4.5 tons | 4 | 60% | 47% | 81% | 56% |
| Non-ducted, 5 tons and up | 1 | 59% | 79% | 48% | 77% |
Every Kepler model in the market
- Kepler models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Kepler in the cold
- All listed models (median, middle 50% and 80%)
- Kepler (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Kepler, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| Kepler, 17°F | 45 | 69% | 73% | 76% | 81% | 86% |
| Kepler, 5°F | 45 | 59% | 64% | 71% | 79% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Kepler, 47°F | 45 | 2.84 | 3.06 | 3.2 | 3.46 | 3.72 |
| Kepler, 17°F | 45 | 2 | 2.14 | 2.32 | 2.51 | 2.61 |
| Kepler, 5°F | 45 | 1.85 | 1.9 | 2 | 2.1 | 2.36 |
Source: NEEP ccASHP list · as of
Top Kepler models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPB-06HRFN10-M1-D | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218851004 | Non-ducted, up to 1.5 tons | 97.0 |
| 2ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26Xcel | 3 | 218857674 | Ducted, up to 1.5 tons | 93.7 |
| 3ODUMOX230-09HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMFA2M-12HRFN10-M1-D | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 8,600 | 26.0 | CEE 25CEE 26XcelES CC | 8 | 218857666 | Non-ducted, up to 1.5 tons | 90.4 |
| 4ODUMOD30-24HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMCD-24HRFN10-M1-D | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 3 | 218857649 | Non-ducted, 2 tons | 90.1 |
| 5ODUMOD30-24HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTJ-24HWFN10-M1-D | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26Xcel | 3 | 218857661 | Ducted, 2 tons | 85.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ductless indoor unit IDUMSEPB-06HRFN10-M1-D | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218851004 | Non-ducted, up to 1.5 tons | 96.6 | 97.0 | 96.1 | 97.0 |
| 2ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26Xcel | 3 | 218857674 | Ducted, up to 1.5 tons | 95.1 | 93.7 | 96.5 | 93.7 |
| 3ODUMOX230-09HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMFA2M-12HRFN10-M1-D | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 8 | 218857666 | Non-ducted, up to 1.5 tons | 93.3 | 90.4 | 96.2 | 90.4 |
| 4ODUMOD30-24HFN10-M1Kepler · ODU Serieswith ductless indoor unit IDUMSEPD-24HRFN10-M1-D | 2 tons24,000 Btu/h · Non-ducted | 78% | 2.54 | 11.7 | 23.0 | 14.0 | CEE 25CEE 26XcelES CC | 3 | 218851003 | Non-ducted, 2 tons | 87.8 | 85.7 | 90.0 | 85.7 |
| 5ODUMOX330-09HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-09HWFN10-M1-D | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26Xcel | 8 | 218857672 | Ducted, up to 1.5 tons | 87.1 | 80.6 | 93.6 | 80.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ODUMOX230-12HFN10-M1 | 2.51 | Non-ducted, up to 1.5 tons | 99% | 218857654 |
| Capacity retention at 5°F | ODUMOX330-09HFN10-M1X | 126% | Non-ducted, up to 1.5 tons | 98% | 218857676 |
| HSPF2 | ODUMOX230-06HFN10-M1X | 14.8 | Non-ducted, up to 1.5 tons | 99% | 218851004 |
| SEER2 | ODUM4OD30-27HFN10-M1D-D | 25.0 | Non-ducted, 2.5 to 3 tons | 97% | 218853746 |
| EER2 | ODUMOX230-06HFN10-M1X | 18.0 | Non-ducted, up to 1.5 tons | 99% | 218851004 |
| Heating capacity at 5°F | ODUMOX630-36HFN10-M3X | 39,000 Btu/h | Ducted, 2.5 to 3 tons | 98% | 218857641 |
Kepler size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D10 of 11 models qualify · AHRI 218857674 | 95.1(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D11 of 11 models have all five ratings · AHRI 218857674 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models qualify · AHRI 218857661 | 78.9(50 is the typical model of its size class)ODUMOD30-24HFN10-M1with ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models have all five ratings · AHRI 218857656 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-D8 of 9 models qualify · AHRI 218856688 | 83.9(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D9 of 9 models have all five ratings · AHRI 218853765 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D10 of 10 models qualify · AHRI 218853768 | 85.3(50 is the typical model of its size class)ODUM6OE30-48HFN10-M1D-D10 of 10 models have all five ratings · AHRI 218853753 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 63.2(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853756 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D11 of 14 models qualify · AHRI 218851004 | 96.6(50 is the typical model of its size class)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D14 of 14 models have all five ratings · AHRI 218851004 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)ODUMOD30-24HFN10-M1Xwith ductless indoor unit IDUMCD-24HRFN10-M1-D3 of 3 models qualify · AHRI 218857649 | 87.8(50 is the typical model of its size class)ODUMOD30-24HFN10-M1with ductless indoor unit IDUMSEPD-24HRFN10-M1-D3 of 3 models have all five ratings · AHRI 218851003 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D6 of 8 models qualify · AHRI 218853766 | 78.8(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D8 of 8 models have all five ratings · AHRI 218853764 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models qualify · AHRI 218853769 | 75.4(50 is the typical model of its size class)ODUM6OE31-48HFN10-M1XD-D4 of 4 models have all five ratings · AHRI 218853767 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 59.0(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853755 |
Newest Kepler certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ODUMOX630-60HFN10-M3Keplerwith ducted air handler IDUMVBM-60D28T6N10-UC | 4 tons50,000 Btu/h · Ducted | 1.80 | 78% | 8.2 | 14.3 | ES CC | 5 | 218864575 |
| ODUMOX630-48HFN10-M3Keplerwith ducted air handler IDUMVBM-60D28T6N10-UC | 4 tons45,000 Btu/h · Ducted | 1.75 | 81% | 8.0 | 14.8 | CEE 25CEE 26XcelES CC | 6 | 218864573 |
| ODUMOD30-36HFN10-M3Kepler · ODU Serieswith ducted air handler IDUMVBM-36C24T4N10-UC | 3 tons36,000 Btu/h · Ducted | 2.00 | 76% | 8.5 | 14.7 | CEE 25CEE 26XcelES CC | 7 | 218864571 |
| ODUMOD30-30HFN10-M3Keplerwith ducted air handler IDUMVBM-36C24T4N10-UC | 2.5 tons29,000 Btu/h · Ducted | 1.90 | 63% | 8.2 | 15.8 | CEE 25 | 7 | 218864568 |
| ODUMOX430-24HFN10-M3Kepler · ODU Serieswith ducted air handler IDUMVBM-24B18T3N10-UC | 2 tons24,000 Btu/h · Ducted | 1.80 | 76% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 5 | 218864565 |
Compare Kepler
Kepler includes these brand names as listed in AHRI: Kepler. Standards are checked against published thresholds; program rules beyond ratings are not checked.