CONTINENTAL vs Stelpro heat pumps

Measured against models of the same size and duct type, Stelpro scores higher on 5 of the 6 ratings. CONTINENTAL has 31 outdoor models, Stelpro has 32 outdoor models. CONTINENTAL and Stelpro have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CONTINENTAL and Stelpro on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Stelpro scores higher on 5 of the 6 ratings.
  • CONTINENTAL
  • Stelpro
  • Other ranked manufacturers
CONTINEN…Stelpro

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCONTINENTALStelpro
Efficiency index63%median —67%median —
COP at 5°F52% (higher)median 2.0051% (higher)median 1.99
Capacity retention at 5°F67%median 96%77%median 94%
HSPF276%median 10.578%median 10.2
SEER264%median 23.067%median 20.8
EER261%median 12.562%median 12.0
Heating capacity at 5°F70%median 19,000 Btu/h76%median 25,600 Btu/h
Outdoor models3132
AHRI certifications4591

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCONTINENTALStelpro
CEE 2025 Tier 1 (Split ASHP)77.4%24 models87.5%28 models
CEE 2026 Tier 1 (Split ASHP)77.4%24 models87.5%28 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)83.9%26 models93.8%30 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate83.9%26 models78.1%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • CONTINENTAL
  • Stelpro
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCONTINENTALStelpro
Ducted, up to 1.5 tons1 · index 29%5 · index 79%
Ducted, 2 tons2 · index 51%3 · index 60%
Ducted, 2.5–3 tons4 · index 58%8 · index 68%
Ducted, 3.5–4.5 tons3 · index 44%8 · index 64%
Non-ducted, up to 1.5 tons12 · index 73%11 · index 63%
Non-ducted, 2 tons3 · index 75%3 · index 55%
Non-ducted, 2.5–3 tons8 · index 61%4 · index 76%
Non-ducted, 3.5–4.5 tonsNone4 · index 67%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCONTINENTALCold-climate score, best modelStelproCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)82.3(50 is the typical model of its size class)SEPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 216082337
Ducted, 2 tons76.2(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models qualify · AHRI 21869690785.7(50 is the typical model of its size class) (higher)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models qualify · AHRI 216082339
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)NDHAMB-36-O3 of 4 models qualify · AHRI 21521372982.5(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models qualify · AHRI 216617677
Ducted, 3.5–4.5 tons63.3(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPCC48ABA13 of 3 models qualify · AHRI 21869691582.7(50 is the typical model of its size class) (higher)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models qualify · AHRI 216617680
Non-ducted, up to 1.5 tons73.8(50 is the typical model of its size class)CDHAS26B-18-Owith ductless indoor unit CDHAS26B-18-IAlso listed as CDHAS26BA-18-O11 of 12 models qualify · AHRI 21521371682.4(50 is the typical model of its size class) (higher)SELB-H09A-Owith ductless indoor unit SELB-H09A-I9 of 11 models qualify · AHRI 216445285
Non-ducted, 2 tons88.4(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models qualify · AHRI 21593136889.4(50 is the typical model of its size class) (higher)SEPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 216082332
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class)NDHAMB-36-O7 of 8 models qualify · AHRI 21521373078.0(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models qualify · AHRI 216617678
Non-ducted, 3.5–4.5 tonsNo models in this size class73.4(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models qualify · AHRI 216617681

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCONTINENTALAll-around score, best modelStelproAll-around score, best model
Ducted, up to 1.5 tons28.8(50 is the typical model of its size class)WSCHV0018BA1-Cwith ducted air handler WECC24ABA11 of 1 models have all five ratings · AHRI 21846132386.5(50 is the typical model of its size class) (higher)SEPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 216082334
Ducted, 2 tons68.3(50 is the typical model of its size class)WSEHV2436BA1-Cwith ducted air handler WPFX24A-C2 of 2 models have all five ratings · AHRI 21869690778.4(50 is the typical model of its size class) (higher)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models have all five ratings · AHRI 216082339
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)NDHAMB-36-O4 of 4 models have all five ratings · AHRI 21521372983.6(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models have all five ratings · AHRI 216617677
Ducted, 3.5–4.5 tons67.1(50 is the typical model of its size class)WSEHV4860BA1-Cwith ducted air handler WPFX48A-C3 of 3 models have all five ratings · AHRI 21869691383.9(50 is the typical model of its size class) (higher)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models have all five ratings · AHRI 216617680
Non-ducted, up to 1.5 tons81.9(50 is the typical model of its size class)CDHAMBB-18-O11 of 12 models have all five ratings · AHRI 21593137083.9(50 is the typical model of its size class) (higher)SELB-H09A-Owith ductless indoor unit SELB-H09A-I11 of 11 models have all five ratings · AHRI 216445285
Non-ducted, 2 tons76.4(50 is the typical model of its size class)CDHAS26BA-24-Owith ductless indoor unit CDHAS26BA-24-I3 of 3 models have all five ratings · AHRI 21593136876.4(50 is the typical model of its size class)SEPB-H24A-Owith ductless indoor unit SEPB-H24A-I3 of 3 models have all five ratings · AHRI 216082326
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class)CDHAMB-36-OAlso listed as CDHAMBB-36-O8 of 8 models have all five ratings · AHRI 21521372878.3(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models have all five ratings · AHRI 216617676
Non-ducted, 3.5–4.5 tonsNo models in this size class75.6(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models have all five ratings · AHRI 216617679

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCONTINENTALStelpro
COP at 5°Fbeats 95% · 2.36CDHAS22B-12-OAlso listed as CDHAS22BA-12-ONon-ducted, up to 1.5 tonsbeats 94% · 2.34SEPB-H24A-ONon-ducted, 2 tons
Capacity retention at 5°Fbeats 96% · 113%CDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 98% · 120%SEPB-H09A-ODucted, up to 1.5 tons
HSPF2beats 98% · 13.5CDHAS26BA-24-ONon-ducted, 2 tonsbeats 99% · 11.0SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-ODucted, 3.5–4.5 tons
SEER2beats 95% · 27.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 96% · 20.4SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-ODucted, 3.5–4.5 tons
EER2beats 95% · 15.4CDHAS26B-09-OAlso listed as CDHAS26BA-09-ONon-ducted, up to 1.5 tonsbeats 95% · 14.0SEPB-H09A-ODucted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hCDHAS26B-24-ONon-ducted, up to 1.5 tonsbeats 97% · 19,000 Btu/hSMZ2B1-H18A-OAlso listed as SMZ2B1V-H18A-ONon-ducted, up to 1.5 tons

More comparisons