Skip to content

Stelpro heat pump efficiency: 32 outdoor models compared

Stelpro has 32 heat pump outdoor models certified with this refrigerant group, in 95 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Stelpro makes. Stelpro has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
32
AHRI certifications
95
Efficiency index
67%
Typical model vs same-size, same-type peers (46 models)
Meet CEE 2025
87.5%
28 models

How Stelpro compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Stelpro against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Stelpro’s own modelsStelpro is strongest on HSPF2 (its typical model beats 79% of comparable models) and weakest on COP at 5°F (52%).
  • Stelpro
  • Middle half of its models
  • Other ranked manufacturers
Stelpro

Source: AHRI Directory, NEEP · as of

Average peer percentile of Stelpro’s models
RatingBeats comparable modelsRankRaw median
Efficiency index46 models scored67%Not ranked—
COP at 5°F46 models scored52%Not ranked2.00
Capacity retention at 5°F46 models scored77%Not ranked94%
HSPF246 models scored79%Not ranked10.2
SEER246 models scored68%Not ranked20.8
EER246 models scored63%Not ranked12.0
Heating capacity at 5°F46 models scored76%Not ranked25,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Stelpro’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Stelpro (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons579%60%88%81%
Ducted, 2 tons360%42%85%58%
Ducted, 2.5 to 3 tons869%45%86%67%
Ducted, 3.5 to 4.5 tons864%46%79%70%
Non-ducted, up to 1.5 tons1165%53%70%66%
Non-ducted, 2 tons357%73%57%47%
Non-ducted, 2.5 to 3 tons477%53%86%76%
Non-ducted, 3.5 to 4.5 tons467%52%83%69%

Every Stelpro model in the market

Stelpro’s 46 models with a known size and duct type, over the shape of the whole catalog.
Stelpro models by size and ratingColoured: Stelpro · grey shapes: all 15,936 models · lines: catalog medians by size
  • Stelpro models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 46 stelpro models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Stelpro in the cold

From NEEP’s cold-climate listings: 27 Stelpro models against all 6,343 listed models.
Stelpro capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical Stelpro model keeps 78% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • Stelpro (median, middle 50%)
Heating capacity, % of its 47°F maximum78%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Stelpro: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Stelpro, 47°F27100%100%100%100%100%
Stelpro, 17°F2772%75%81%86%94%
Stelpro, 5°F2763%71%78%82%85%
Stelpro: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Stelpro, 47°F272.863.13.223.443.54
Stelpro, 17°F271.982.122.352.522.6
Stelpro, 5°F271.861.93222.1

Source: NEEP ccASHP list · as of

Top Stelpro models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Stelpro cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1SEPB-H24A-OStelpro · SICB1 Serieswith ductless indoor unit SICB1-H24A-I2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC3216082332Non-ducted, 2 tons90.1
2SEPB-H24A-OStelpro · SFCB1 Serieswith ducted air handler SFCB1-H24A-I2 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26XcelES CC3216082339Ducted, 2 tons85.8
3SELB-H09A-OStelpro · Elite Bwith ductless indoor unit SELB-H09A-I1 ton9,000 Btu/h · Non-ducted100%2.0911.09,00025.0CEE 25CEE 26XcelES CC2216445285Non-ducted, up to 1.5 tons83.4
4SEPB-H18A-OStelpro · SFCB1 Serieswith ducted air handler SFCB1-H18A-I1.5 tons17,500 Btu/h · Ducted92%2.1011.118,00018.4CEE 25CEE 26XcelES CC3216082337Ducted, up to 1.5 tons82.9
5SMZ4B1-H36A-OStelpro · SMZ SeriesAlso listed as SMZ4B1V-H36A-O3 tons36,000 Btu/h · Ducted106%2.0010.438,00019.4CEE 25CEE 26XcelES CC3216617677Ducted, 2.5 to 3 tons82.7

All-around best

Top 5 Stelpro models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1SEPB-H09A-OStelpro · SFCB1 Serieswith ducted air handler SFCB1-H09A-I1 ton9,000 Btu/h · Ducted120%1.8513.820.514.0CEE 25CEE 26XcelES CC3216082334Ducted, up to 1.5 tons87.080.493.580.4
2SELB-H09A-OStelpro · Elite Bwith ductless indoor unit SELB-H09A-I1 ton9,000 Btu/h · Non-ducted100%2.0911.025.013.7CEE 25CEE 26XcelES CC2216445285Non-ducted, up to 1.5 tons85.183.486.783.4
3SMZ5B1-H48A-OStelpro · SMZ SeriesAlso listed as SMZ5B1V-H48A-O4 tons47,000 Btu/h · Ducted100%2.0011.020.411.7CEE 25CEE 26XcelES CC3216617680Ducted, 3.5 to 4.5 tons84.382.686.082.6
4SMZ4B1-H36A-OStelpro · SMZ SeriesAlso listed as SMZ4B1V-H36A-O3 tons36,000 Btu/h · Ducted106%2.0010.419.412.0CEE 25CEE 26XcelES CC3216617677Ducted, 2.5 to 3 tons83.982.785.182.7
5SMZ2B1-H18A-OStelpro · SMZ SeriesAlso listed as SMZ2B1V-H18A-O1.5 tons19,000 Btu/h · Non-ducted95%2.0010.425.015.0CEE 25CEE 26XcelES CC3216617670Non-ducted, up to 1.5 tons83.174.591.674.5

Best model on each rating

Stelpro’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FSEPB-H24A-O2.34Non-ducted, 2 tons95%216082326
Capacity retention at 5°FSEPB-H09A-O120%Ducted, up to 1.5 tons98%216082334
HSPF2SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O11.0Ducted, 3.5 to 4.5 tons99%216617680
SEER2SEPB-H09A-O27.4Non-ducted, up to 1.5 tons96%216082321
EER2SEPB-H09A-O14.0Ducted, up to 1.5 tons95%216082334
Heating capacity at 5°FSDB1-H36A-O39,000 Btu/hDucted, 2.5 to 3 tons98%216082175

All 32 Stelpro models in Explore

Stelpro size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Stelpro: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons82.9(50 is the typical model of its size class)SEPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 21608233787.0(50 is the typical model of its size class)SEPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 216082334
Ducted, 2 tons85.8(50 is the typical model of its size class)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models qualify · AHRI 21608233978.6(50 is the typical model of its size class)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models have all five ratings · AHRI 216082339
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models qualify · AHRI 21661767783.9(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models have all five ratings · AHRI 216617677
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models qualify · AHRI 21661768084.3(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models have all five ratings · AHRI 216617680
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)SELB-H09A-Owith ductless indoor unit SELB-H09A-I9 of 11 models qualify · AHRI 21644528585.1(50 is the typical model of its size class)SELB-H09A-Owith ductless indoor unit SELB-H09A-I11 of 11 models have all five ratings · AHRI 216445285
Non-ducted, 2 tons90.1(50 is the typical model of its size class)SEPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 21608233278.3(50 is the typical model of its size class)SEPB-H24A-Owith ductless indoor unit SEPB-H24A-I3 of 3 models have all five ratings · AHRI 216082326
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models qualify · AHRI 21661767878.8(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models have all five ratings · AHRI 216617676
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models qualify · AHRI 21661768175.4(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models have all five ratings · AHRI 216617679

All-around board, every manufacturer

Newest Stelpro certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Stelpro outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
SELB-H24A-OStelpro · Elite Bwith ductless indoor unit SELB-H24B-I2 tons24,000 Btu/h · Non-ducted2.0080%9.522.5CEE 25CEE 26XcelES CC2218083337
SELB-H18A-OStelpro · Elite Bwith ductless indoor unit SELB-H18B-I1.5 tons18,000 Btu/h · Non-ducted1.90100%9.521.0CEE 25CEE 26XcelES CC2218083336
SELB-H12A-OStelpro · Elite Bwith ductless indoor unit SELB-H12B-I1 ton12,000 Btu/h · Non-ducted2.0088%9.523.0CEE 25CEE 26XcelES CC2218083335
SELB-H09A-OStelpro · Elite Bwith ductless indoor unit SELB-H09B-I1 ton9,000 Btu/h · Non-ducted2.09100%11.025.0CEE 25CEE 26XcelES CC2218083334
SDB1-H60A-OStelpro · SDB Serieswith indoor coil SMCB1-H60A2128-I and furnace C120-M-V4.5 tons52,000 Btu/h · Ducted1.8079%8.515.7CEE 25CEE 26XcelES CC5217618181

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Stelpro

Manufacturers of a similar size, side by side.

Stelpro includes these brand names as listed in AHRI: STELPRO. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter