Stelpro heat pump efficiency: 32 outdoor models compared
Stelpro has 32 heat pump outdoor models certified with this refrigerant group, in 91 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Stelpro makes. Stelpro has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 32
- AHRI certifications
- 91
- Efficiency index
- 67%
- Typical model vs same-size, same-type peers (46 models)
- Meet CEE 2025
- 87.5%
- 28 models
How Stelpro compares with comparable models
- Stelpro
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index46 models scored | 67% | Not ranked | — |
| COP at 5°F46 models scored | 51% | Not ranked | 1.99 |
| Capacity retention at 5°F46 models scored | 77% | Not ranked | 94% |
| HSPF246 models scored | 78% | Not ranked | 10.2 |
| SEER246 models scored | 67% | Not ranked | 20.8 |
| EER246 models scored | 62% | Not ranked | 12.0 |
| Heating capacity at 5°F46 models scored | 76% | Not ranked | 25,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 87.5% | 28 |
| CEE 2026 Tier 1 (Split ASHP) | 87.5% | 28 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 93.8% | 30 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 78.1% | 25 |
Sizes and duct types offered
- Stelpro (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 79% | 59% | 88% | 80% |
| Ducted, 2 tons | 3 | 60% | 43% | 85% | 59% |
| Ducted, 2.5–3 tons | 8 | 68% | 45% | 86% | 68% |
| Ducted, 3.5–4.5 tons | 8 | 64% | 46% | 79% | 70% |
| Non-ducted, up to 1.5 tons | 11 | 63% | 52% | 69% | 63% |
| Non-ducted, 2 tons | 3 | 55% | 67% | 55% | 45% |
| Non-ducted, 2.5–3 tons | 4 | 76% | 53% | 85% | 76% |
| Non-ducted, 3.5–4.5 tons | 4 | 67% | 52% | 82% | 70% |
Every Stelpro model in the market
- Stelpro models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Stelpro models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1SEPB-H24A-OStelpro · SICB1 Serieswith ductless indoor unit SICB1-H24A-I | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 3 | 216082332 | Non-ducted, 2 tons | 89.4 |
| 2SEPB-H24A-OStelpro · SFCB1 Serieswith ducted air handler SFCB1-H24A-I | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 216082339 | Ducted, 2 tons | 85.7 |
| 3SMZ5B1-H48A-OStelpro · SMZ SeriesAlso listed as SMZ5B1V-H48A-O | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 48,000 | 20.4 | CEE 25CEE 26XcelES CC | 3 | 216617680 | Ducted, 3.5–4.5 tons | 82.7 |
| 4SMZ4B1-H36A-OStelpro · SMZ SeriesAlso listed as SMZ4B1V-H36A-O | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26XcelES CC | 3 | 216617677 | Ducted, 2.5–3 tons | 82.5 |
| 5SELB-H09A-OStelpro · Elite Bwith ductless indoor unit SELB-H09A-I | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.09 | 11.0 | 9,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 216445285 | Non-ducted, up to 1.5 tons | 82.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1SEPB-H09A-OStelpro · SFCB1 Serieswith ducted air handler SFCB1-H09A-I | 1 ton9,000 Btu/h · Ducted | 120% | 1.85 | 13.8 | 20.5 | 14.0 | CEE 25CEE 26XcelES CC | 3 | 216082334 | Ducted, up to 1.5 tons | 86.5 | 79.9 | 93.2 | 79.9 |
| 2SELB-H09A-OStelpro · Elite Bwith ductless indoor unit SELB-H09A-I | 1 ton9,000 Btu/h · Non-ducted | 100% | 2.09 | 11.0 | 25.0 | 13.7 | CEE 25CEE 26XcelES CC | 1 | 216445285 | Non-ducted, up to 1.5 tons | 83.9 | 82.4 | 85.4 | 82.4 |
| 3SMZ5B1-H48A-OStelpro · SMZ SeriesAlso listed as SMZ5B1V-H48A-O | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 216617680 | Ducted, 3.5–4.5 tons | 83.9 | 82.7 | 85.1 | 82.7 |
| 4SMZ4B1-H36A-OStelpro · SMZ SeriesAlso listed as SMZ4B1V-H36A-O | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 216617677 | Ducted, 2.5–3 tons | 83.6 | 82.5 | 84.8 | 82.5 |
| 5SMZ5B1-H55A-OStelpro · SMZ SeriesAlso listed as SMZ5B1V-H55A-O | 4.5 tons53,000 Btu/h · Ducted | 87% | 2.10 | 10.7 | 20.0 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 216617683 | Ducted, 3.5–4.5 tons | 82.0 | 81.2 | 82.8 | 81.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | SEPB-H24A-O | 2.34 | Non-ducted, 2 tons | 94% | 216082326 |
| Capacity retention at 5°F | SEPB-H09A-O | 120% | Ducted, up to 1.5 tons | 98% | 216082334 |
| HSPF2 | SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O | 11.0 | Ducted, 3.5–4.5 tons | 99% | 216617680 |
| SEER2 | SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O | 20.4 | Ducted, 3.5–4.5 tons | 96% | 216617680 |
| EER2 | SEPB-H09A-O | 14.0 | Ducted, up to 1.5 tons | 95% | 216082334 |
| Heating capacity at 5°F | SMZ2B1-H18A-OAlso listed as SMZ2B1V-H18A-O | 19,000 Btu/h | Non-ducted, up to 1.5 tons | 97% | 216617670 |
Stelpro size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.3(50 is the typical model of its size class)SEPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 216082337 | 86.5(50 is the typical model of its size class)SEPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 216082334 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models qualify · AHRI 216082339 | 78.4(50 is the typical model of its size class)SEPB-H24A-Owith ducted air handler SFCB1-H24A-I3 of 3 models have all five ratings · AHRI 216082339 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models qualify · AHRI 216617677 | 83.6(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O8 of 8 models have all five ratings · AHRI 216617677 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models qualify · AHRI 216617680 | 83.9(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O8 of 8 models have all five ratings · AHRI 216617680 |
| Non-ducted, up to 1.5 tons | 82.4(50 is the typical model of its size class)SELB-H09A-Owith ductless indoor unit SELB-H09A-I9 of 11 models qualify · AHRI 216445285 | 83.9(50 is the typical model of its size class)SELB-H09A-Owith ductless indoor unit SELB-H09A-I11 of 11 models have all five ratings · AHRI 216445285 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)SEPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 216082332 | 76.4(50 is the typical model of its size class)SEPB-H24A-Owith ductless indoor unit SEPB-H24A-I3 of 3 models have all five ratings · AHRI 216082326 |
| Non-ducted, 2.5–3 tons | 78.0(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models qualify · AHRI 216617678 | 78.3(50 is the typical model of its size class)SMZ4B1-H36A-OAlso listed as SMZ4B1V-H36A-O4 of 4 models have all five ratings · AHRI 216617676 |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models qualify · AHRI 216617681 | 75.6(50 is the typical model of its size class)SMZ5B1-H48A-OAlso listed as SMZ5B1V-H48A-O4 of 4 models have all five ratings · AHRI 216617679 |
Newest Stelpro certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SDB1-H60A-OStelpro · SDB Serieswith indoor coil SMCB1-H60A2128-I and furnace C120-M-V | 4.5 tons52,000 Btu/h · Ducted | 1.80 | 79% | 8.5 | 15.7 | CEE 25CEE 26XcelES CC | 5 | 217618181 |
| SDB1-H48A-OStelpro · SDB Serieswith indoor coil SMCB1-H60A2128-I and furnace C120-M-V | 4 tons45,000 Btu/h · Ducted | 1.75 | 89% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 217618179 |
| SDB1-H36A-OStelpro · SDB Serieswith indoor coil SACB1-H36A2124-I and furnace C120-M-V | 3 tons35,000 Btu/h · Ducted | 1.90 | 89% | 9.3 | 15.2 | CEE 25CEE 26XcelES CC | 8 | 217618177 |
| SDB1-H30A-OStelprowith indoor coil SACB1-H36A1724-I and furnace C75-2-V | 2.5 tons29,000 Btu/h · Ducted | 1.75 | 97% | 8.4 | 14.9 | CEE 25CEE 26XcelES CC | 6 | 217618173 |
| SDB1-H24A-OStelpro · SDB Serieswith indoor coil SACB1-H24A1718-I and furnace C75-2-V | 2 tons24,000 Btu/h · Ducted | 1.80 | 88% | 9.1 | 15.3 | CEE 25CEE 26XcelES CC | 7 | 217618171 |
Compare Stelpro